← All vessels
ATLANTIS PQ
Industrial Vessel · Offshore class · USCG Heartland District (CGD-H) · Other hulls named ATLANTIS PQ
ATLANTIS PQ is a industrial vessel. The Coast Guard has recorded 54 inspections since 2006, most recently in February 2026, along with 40 deficiencies, 1 operational control and 1 casualty investigation in 2011.
Records from 2006 to 2026. Most recent: inspection, 24 February 2026.
- Built
- Not recorded
- Last inspected
- 24 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 40 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2011
Identity
9265768 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WPYW299
676287
Flag
UNITED STATES
—
Maury page id
psix-676287
Inspections, by type
…with no type recorded5
Years with a record
18 calendar years (2006–2026)
The 54 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it35663 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 54
24 February 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8314977
7 January 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8319839
30 September 2025
COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8244874
31 July 2024
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7974983
24 May 2023
MTSA Verification · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7695992
9 February 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7650034
1 July 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7500971
7 April 2022
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7428738
21 July 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7263238
13 June 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7264223
5 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7168991
26 January 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7130992
8 January 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7122622
27 October 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7085031
17 September 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7068645
21 April 2020
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7341224
20 February 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6912251
17 January 2020
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6881632
10 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6709448
31 May 2019
Security Plan Review - ASP
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6993448
17 January 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6641885
8 January 2019
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6607795
20 December 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6327004
15 November 2017
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6309903
19 October 2017
MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293158
31 August 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6256225
28 August 2017
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6249068
3 April 2017
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6116988
6 March 2017
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6100202
22 August 2016
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5979951
13 July 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5954705
11 July 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5937078
6 July 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5931936
17 June 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5910454
15 June 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913075
15 June 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922461
8 June 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5902639
15 March 2016
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5834997
15 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5776961
9 October 2015
COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5739704
6 October 2014
Administrative Inspection · Annual Inspection · Internal Structural Exam · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4884390
19 July 2012
Hull Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4458269
2 February 2011
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3939116
13 January 2011
Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4015228
15 November 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3891970
8 November 2010
Re-Inspection · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4015165
23 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3701464
6 November 2008
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3447340
31 July 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3014175
15 September 2006
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2778861
25 August 2006
Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2778316
1 August 2006
Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2732820
5 May 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2644881
1 May 2006
Construction Oversight
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2637704
Deficiency record · 40
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 July 2024
Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Observed multiple emergency lights inoperable at lifesaving embarkation decks, stair ways and landings, passageways and means of egress around the facility and its perimeter, near machinery spaces/equipment, at the heli-deck landing area, and more. Restore all emergency lighting on board to a satisfactory and functioning status as initially installed/intended.
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 8 January 2021
Resolved
Two of the three cranes emergency stops did not work. Emergency stops at the motors did work. Require evidence of all three crane's emergency stops functioning properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 January 2020
Resolved
01 The emergency equipment provided shall be maintained in good condition at all times. The maintenance required by OEM for lubrication of the falls is not taking place. Cables on #3 LB were rusting. Lubricate all. 33 CFR 146.15. 50c.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 January 2020
Resolved
Main gas turbines #1, 2, and 3 were leaking excessively from the fwd and aft seals on the generator. Windings have significant oil spray. Repair as necessary. Provide proposal to the USCG. 46 CFR 58.10-15. 50c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 8 January 2019
Resolved
A currently FSP was unable to be provided to the CG Inspector upon request during COI Annual Exam. A valid FSP with updated reivisions approved by the Coast Guard must be onboard at all times. Provide verification that an approved FSP is onboard.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 19 October 2017
Resolved
Lifeboat#2 has unreliable packing gland due to it being knocked loose when the break release cable wound around the propeller shaft. Stand-by vsl required to be on scene until weather is adequate for LB#2 launch to ensure reliability of packing gland repair/readjustment.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 19 October 2017
Resolved
Lifeboat # 1 and 3 had leaking air bottle regulators. Replace/renew to eliminate leakage.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 October 2017
Resolved
Washers and Dryers located in TLQs were not secured. Danger of dryer on second level of sliding off onto personnel.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 October 2017
Resolved
Handrails on the Northwest column has broken welds and were held together with scaffolding. Renew replace as orginal.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 19 October 2017
Resolved
Fire boundary insulating materials were worn/torn and/or had "dummy pins" in numerous areas. Repair and replace to restore required fire protection IAW vsls fir control plan (DWG#1440-50-SA-DG-070-5504)
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 15 June 2016
Resolved
Several liferafts have stowage height of 25 meters and the unit's current draft is at least 26 meters. Ensure liferafts are stowed at required height limits or replace liferafts with ones that canmeet the stowage height.
Lifesaving › Lifeboat › Propulsion Engine
Issued 15 June 2016
Resolved
Lifeboat # 4 has an idling issue due to a faulty fuel pump manufactured by Lister. Ensure fuel pump is replaced/repaired to original condition and idle issue is corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 14 October 2015
Resolved
Multiple life rings were found to be unserviceable. Replace rings with approved life rings.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 October 2015
Resolved
2 breaker panels in ALQ were labled as spare but were energized. Locate the load and label correctly.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 October 2014
Resolved
The A-60 Galley-to-Serving Line Door: is binding against the door frame and not fully closing. The upper door hinge is also damaged and has a bent hinge pin. Prove proper operation of this door. Cite 46 CFR 108.135.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 9 October 2014
Resolved
Approximately 75% of the CO2 System Flexible Loops (hoses) for all three Main Gas Turbine Generators are showing dry rot on the hose outer jackets. Replace all aged/deteriorated hoses due to unknown condition of inner linings. Cite 46 CFR 107.235 (b).
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 9 October 2014
Resolved
Found two open MCT blocks in the North wall of the Production Module Electric Building, facing the Production Area. The MCT had two cables removed at some point in the past without the MCT being properly re-sealed. Affect repairs by installing the proper 'blanks'. Cite 46 CFR 108.133.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 9 October 2014
Resolved
Deteriorated chill water piping insulation is allowing excess condensation to form & creating slip, electrical & biological hazards. Provide a plan to restore the integrity/function of insulation on these lines/systems and remove the current hazards listed. Cite 33 CFR 142.84, 46 CFR 109.203.
Lifesaving › Launching Appliances › Falls
Issued 8 October 2014
Resolved
Provide replacement Rescue Boat. If rental to be used temporarily, boat must be compatible w/davit & permanent replacement plan to be provided. All related approval, weight tests & release gear certificates to be provided for the temp/permanent replacement boat. Davit fall change/weight test also overdue. Complete both/provide documentation for review. Cite 46 CFR 108.560, 46 CFR 109.301(j).
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 October 2014
Resolved
Numerous E-Lights were found to be partially or fully extinguished throughout the hull of the facility. Prove proper operation of all E-Lights and maintain in a ready state at all times. Cite 46 CFR 111.75-15(c)(2).
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 6 October 2014
Resolved
FOI found w/out Rescue Boat upon arrival. Boat removed due to technical difficulties w/boat maintenance. Further research found none of the lifeboat winches rated for proper retrieval speed to allow lifeboats to act as a Rescue Boat. Provide certificated Standby Vessel on location to serve in place of required Rescue Boat until operational Rescue Boat can be provided. 46 CFR 108.560, 108.570(f).
Stability › Watertight Integrity › General
Issued 11 October 2012
Resolved
Current watertight doors are not operating as required. Inspection revealed that the WTD's 407/408 and WTD 107/108 did not fully close thus rendering them ineffective. Prove proper operation of all WTD's on board. Alarms that coincide with the operation of the WTD's are also not operating as required. Prove proper operation of all alarms. Ensure alarms are audible on both sides of the doors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2006
Resolved
Demonstrate compliance with 46 CFR 111.105-33 for all electrical installations in hazardous locations to the satisfaction of the atending USCG marine inspector. Prior to COI.
Fire Fighting › Fire Main › Pressure
Issued 1 May 2006
Resolved
Demonstrate fire protection system for helicopter landing deck is capable of discharging from each hose at 100 psi prior to helicopter fueling operations.
Fire Fighting › Fire Pumps › Pressure
Issued 1 May 2006
Resolved
Demonstrate proper operation of all diesel driven fire pumps prior to operation and COI to the satisfaction of attending USCG marine inspector.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 May 2006
Resolved
Demonstrate man overboard drill with fast rescue craft to the satisfaction of attending USCG marine inspector prior to COI.
Deck/Cargo › Ballast › Tank
Issued 1 May 2006
Resolved
Immediately prior to departure from Ingleside, all ballast sensors are to be cleaned and proven to have a deviation of less than the agreed maximum deviation of 4 inches to the satisfaction of the attending ABS surveyor.
Deck/Cargo › Ballast › Tank
Issued 1 May 2006
Resolved
During all ballasting operations and mooring chain installations, all tank soundings are to be manually strapped, recorded, and entered into the stability program manually. Manual input of ballast tank levels is to continue until such time as the ballast tank sensors can be proven accurate to the satisfaction of the attending ABS surveyor.
Deck/Cargo › Ballast › Tank
Issued 1 May 2006
Resolved
During all ballasting operations and mooring chain installations, all tank soundings are to be manually strapped, recorded, and entered into the stability program manually. Manual input of ballast tank levels is to continue until such time as the ballast tank sensors can be proven accurate to the satisfaction of the attending ABS surveyor.
Deck/Cargo › Ballast › Tank
Issued 1 May 2006
Resolved
Records indicating compliance with the "Verification and Maintenance Procedure for Hull Tank Sensors" will be submitted weekly to ABS surveyor [name withheld] This is to include tank levels and sensor repairs and is to continue after installation of any new sensor to ensure there are no additonal issues.
Deck/Cargo › Ballast › Tank
Issued 1 May 2006
Resolved
Regular updates are to be provided to ABS surveyor [name withheld] on the procurement status and installation schedule of any and/or all new ballast sensors.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 1 May 2006
Resolved
Make all air receivers available for inspection and provide all information and access required by attending USCG marine inspector prior to COI.
Engineering › Bilge Water Management System › Eductor
Issued 1 May 2006
Resolved
Demonstrate compliance with 46CFR58.60 and 46CFR111.107 for all industrial systems to the satisfaction of attending USCG marine inspector prior to COI.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 1 May 2006
Resolved
Obtain approval of operating manual and construction portfolio prior to COI.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 May 2006
Resolved
Obtain USCG approval of Emergency Evacuation Plan IAW 33 CFR 146.140 prior to COI.
Communications › Alarms/Indicators › General Alarm
Issued 1 May 2006
Resolved
Once offshore and operating all machinery/equipment, demonstrate that the general emergency alarm signal produces minimum sound pressure levels above ambient noise levels required by 46 CFR 113.25-12 and 46 CFR 113.50-15 for public address system prior to COI
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 May 2006
Resolved
Verify proper operation of and associated fire fighting equipment for all gas turbines to the satisfaction of the attending USCG marine inspector prior to COI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 May 2006
Resolved
Complete all outstanding requirements from "ABS Punch List" dated 11 July 2006 to the satisfaction of the attending ABS surveyor and/or USCG marine inspector as dictated on the punchlist.
Fire Fighting › Fire Main › Pressure
Issued 1 May 2006
Resolved
Prior to departure from Ingleside, hydro test fire main section associated with the ALQ. Also test jockey water pumps.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 1 May 2006
Resolved
The actuators that are installed on the Halton fire dampers - Model # Air Tourque AT 101 S12 B - is different than that listed on the BV schedule of approval which lists the Air Torque Model # AT 100 S10 B. Provide manufacturer documentation that the installed AT 101 S12 B actuators do not materially alter the fire rated performance of the damper.
Casualty record · 1
6 March 2011Routine · role: Involved in a Marine Casualty · activity 3985007
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.