ATLANTIS PQ is a industrial vessel. The Coast Guard has recorded 54 inspections since 2006, most recently in February 2026, along with 40 deficiencies, 1 operational control and 1 casualty investigation in 2011.

Records from 2006 to 2026. Most recent: inspection, 24 February 2026.

Built
Not recorded
Last inspected
24 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9265768 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WPYW299
676287
Flag
UNITED STATES
—
Maury page id
psix-676287

Inspections, by type

…with no type recorded5
Years with a record 18 calendar years (2006–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it35663 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 54

24 February 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8314977
7 January 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8319839
30 September 2025 COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8244874
31 July 2024 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7974983
24 May 2023 MTSA Verification · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7695992
9 February 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7650034
1 July 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7500971
7 April 2022 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7428738
21 July 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7263238
13 June 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7264223
5 April 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7168991
26 January 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7130992
8 January 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7122622
27 October 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7085031
17 September 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7068645
21 April 2020 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7341224
20 February 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6912251
17 January 2020 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6881632
10 June 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6709448
31 May 2019 Security Plan Review - ASP
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6993448
17 January 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6641885
8 January 2019 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6607795
20 December 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6327004
15 November 2017 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6309903
19 October 2017 MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293158
31 August 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6256225
28 August 2017 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6249068
3 April 2017 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6116988
6 March 2017 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6100202
22 August 2016 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5979951
13 July 2016 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5954705
11 July 2016 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5937078
6 July 2016 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5931936
17 June 2016 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5910454
15 June 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913075
15 June 2016 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922461
8 June 2016 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5902639
15 March 2016 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5834997
15 October 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5776961
9 October 2015 COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5739704
6 October 2014 Administrative Inspection · Annual Inspection · Internal Structural Exam · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4884390
19 July 2012 Hull Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4458269
2 February 2011 Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3939116
13 January 2011 Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4015228
15 November 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3891970
8 November 2010 Re-Inspection · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4015165
23 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3701464
6 November 2008 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3447340
31 July 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3014175
15 September 2006 Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2778861
25 August 2006 Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2778316
1 August 2006 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2732820
5 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2644881
1 May 2006 Construction Oversight
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2637704

Deficiency record · 40

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 July 2024 Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Observed multiple emergency lights inoperable at lifesaving embarkation decks, stair ways and landings, passageways and means of egress around the facility and its perimeter, near machinery spaces/equipment, at the heli-deck landing area, and more. Restore all emergency lighting on board to a satisfactory and functioning status as initially installed/intended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2024
Resolved 19 August 2024
Resolution: Cleared deficiency after receiving email correspondence with tracking order numbers of lights scheduled for replacement and order numbers.
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 8 January 2021 Resolved
Two of the three cranes emergency stops did not work. Emergency stops at the motors did work. Require evidence of all three crane's emergency stops functioning properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 2 February 2021
Resolution: Received video and closed work order confirming completion of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 January 2020 Resolved
01 The emergency equipment provided shall be maintained in good condition at all times. The maintenance required by OEM for lubrication of the falls is not taking place. Cables on #3 LB were rusting. Lubricate all. 33 CFR 146.15. 50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2020
Resolved 4 March 2020
Resolution: Correspondence by compliance lead to remove def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 January 2020 Resolved
Main gas turbines #1, 2, and 3 were leaking excessively from the fwd and aft seals on the generator. Windings have significant oil spray. Repair as necessary. Provide proposal to the USCG. 46 CFR 58.10-15. 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2020
Resolved 4 March 2020
Resolution: Correspondence by compliance lead to remove def.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 8 January 2019 Resolved
A currently FSP was unable to be provided to the CG Inspector upon request during COI Annual Exam. A valid FSP with updated reivisions approved by the Coast Guard must be onboard at all times. Provide verification that an approved FSP is onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2019
Resolved 29 January 2019
Resolution: Prior to exam completion, upon request by the FSO, the CSO sent an approved FSP with the must up to date revisions by e-mail.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 19 October 2017 Resolved
Lifeboat#2 has unreliable packing gland due to it being knocked loose when the break release cable wound around the propeller shaft. Stand-by vsl required to be on scene until weather is adequate for LB#2 launch to ensure reliability of packing gland repair/readjustment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 24 October 2017
Resolution: Received email from Barge Supervisor stating that lifeboat #2 was run ahead in the water with no leaks.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 19 October 2017 Resolved
Lifeboat # 1 and 3 had leaking air bottle regulators. Replace/renew to eliminate leakage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 31 October 2017
Resolution: Received email from Barge Supervisor stating that lifeboats' air systems had been corrected.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 October 2017 Resolved
Washers and Dryers located in TLQs were not secured. Danger of dryer on second level of sliding off onto personnel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 31 October 2017
Resolution: Received email from Barge Sup stating that the dryers had been properly secured.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 October 2017 Resolved
Handrails on the Northwest column has broken welds and were held together with scaffolding. Renew replace as orginal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 7 December 2017
Resolution: Received email from Marine Team Lead with accompanying pictures showing that the handrails had been repaired.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 19 October 2017 Resolved
Fire boundary insulating materials were worn/torn and/or had "dummy pins" in numerous areas. Repair and replace to restore required fire protection IAW vsls fir control plan (DWG#1440-50-SA-DG-070-5504)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 December 2017
Resolution: Received email from [name withheld] the Barge Supervisor of Atlantis that all insulation identified as torn during the inspection had been repaired. This clears the last outstanding 835 that Atlantis had opened.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 15 June 2016 Resolved
Several liferafts have stowage height of 25 meters and the unit's current draft is at least 26 meters. Ensure liferafts are stowed at required height limits or replace liferafts with ones that canmeet the stowage height.
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 23 June 2016
Resolution: Recieved email with accompanying pictures showing that this deficiency had been cleared.
Lifesaving › Lifeboat › Propulsion Engine
Issued 15 June 2016 Resolved
Lifeboat # 4 has an idling issue due to a faulty fuel pump manufactured by Lister. Ensure fuel pump is replaced/repaired to original condition and idle issue is corrected.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 23 June 2016
Resolution: Recieved email with accompanying pictures showing that this deficiency had been cleared.
Lifesaving › Lifebuoys › Serviceable
Issued 14 October 2015 Resolved
Multiple life rings were found to be unserviceable. Replace rings with approved life rings.
Condition: Damaged By Earlier Event
Due 21 October 2015
Resolved 16 October 2015
Resolution: Received email from OIM that life rings were all inspected and 5 life rings were renewed
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 October 2015 Resolved
2 breaker panels in ALQ were labled as spare but were energized. Locate the load and label correctly.
Due 21 October 2015
Resolved 16 October 2015
Resolution: Received email from OIM stating that the electrical panels were updated with the correct circuit iformation.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 October 2014 Resolved
The A-60 Galley-to-Serving Line Door: is binding against the door frame and not fully closing. The upper door hinge is also damaged and has a bent hinge pin. Prove proper operation of this door. Cite 46 CFR 108.135.
Due 31 October 2014
Resolved 18 October 2014
Resolution: Received documentation showing satisfactory completion.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 9 October 2014 Resolved
Approximately 75% of the CO2 System Flexible Loops (hoses) for all three Main Gas Turbine Generators are showing dry rot on the hose outer jackets. Replace all aged/deteriorated hoses due to unknown condition of inner linings. Cite 46 CFR 107.235 (b).
Due 7 November 2014
Resolved 21 October 2014
Resolution: Received documentation showing satisfactory completion.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 9 October 2014 Resolved
Found two open MCT blocks in the North wall of the Production Module Electric Building, facing the Production Area. The MCT had two cables removed at some point in the past without the MCT being properly re-sealed. Affect repairs by installing the proper 'blanks'. Cite 46 CFR 108.133.
Due 27 October 2014
Resolved 13 October 2014
Resolution: Received documentation showing satisfactory completion.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 9 October 2014 Resolved
Deteriorated chill water piping insulation is allowing excess condensation to form & creating slip, electrical & biological hazards. Provide a plan to restore the integrity/function of insulation on these lines/systems and remove the current hazards listed. Cite 33 CFR 142.84, 46 CFR 109.203.
Due 14 November 2014
Resolved 23 November 2014
Resolution: Cleared 23Dec14 based on the proposal that was received, reviewed & accepted. Note that this project has a large work scope that will take an extended amount of time.
Lifesaving › Launching Appliances › Falls
Issued 8 October 2014 Resolved
Provide replacement Rescue Boat. If rental to be used temporarily, boat must be compatible w/davit & permanent replacement plan to be provided. All related approval, weight tests & release gear certificates to be provided for the temp/permanent replacement boat. Davit fall change/weight test also overdue. Complete both/provide documentation for review. Cite 46 CFR 108.560, 46 CFR 109.301(j).
Due 7 November 2014
Resolved 14 November 2014
Resolution: Received documentation showing satisfactory completion. Cleared by the OCS Sup, E. Sykes.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 October 2014 Resolved
Numerous E-Lights were found to be partially or fully extinguished throughout the hull of the facility. Prove proper operation of all E-Lights and maintain in a ready state at all times. Cite 46 CFR 111.75-15(c)(2).
Due 7 November 2014
Resolved 27 October 2014
Resolution: Received documentation showing satisfactory completion.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 6 October 2014 Resolved
FOI found w/out Rescue Boat upon arrival. Boat removed due to technical difficulties w/boat maintenance. Further research found none of the lifeboat winches rated for proper retrieval speed to allow lifeboats to act as a Rescue Boat. Provide certificated Standby Vessel on location to serve in place of required Rescue Boat until operational Rescue Boat can be provided. 46 CFR 108.560, 108.570(f).
Action required: 705 - Other - as specified
Due 7 October 2014
Resolved 7 October 2014
Resolution: Standby Vessel on location in 1-day as required. Witnessed the same while still onboard.
Stability › Watertight Integrity › General
Issued 11 October 2012 Resolved
Current watertight doors are not operating as required. Inspection revealed that the WTD's 407/408 and WTD 107/108 did not fully close thus rendering them ineffective. Prove proper operation of all WTD's on board. Alarms that coincide with the operation of the WTD's are also not operating as required. Prove proper operation of all alarms. Ensure alarms are audible on both sides of the doors.
Action required: 705 - Other - as specified
Due 25 October 2012
Resolved 21 October 2012
Resolution: Witnessed by ABS Morgan City.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2006 Resolved
Demonstrate compliance with 46 CFR 111.105-33 for all electrical installations in hazardous locations to the satisfaction of the atending USCG marine inspector. Prior to COI.
Action required: 705 - Other - as specified
Resolved 13 September 2007
Fire Fighting › Fire Main › Pressure
Issued 1 May 2006 Resolved
Demonstrate fire protection system for helicopter landing deck is capable of discharging from each hose at 100 psi prior to helicopter fueling operations.
Action required: 705 - Other - as specified
Resolved 13 September 2007
Fire Fighting › Fire Pumps › Pressure
Issued 1 May 2006 Resolved
Demonstrate proper operation of all diesel driven fire pumps prior to operation and COI to the satisfaction of attending USCG marine inspector.
Action required: 705 - Other - as specified
Resolved 13 September 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 May 2006 Resolved
Demonstrate man overboard drill with fast rescue craft to the satisfaction of attending USCG marine inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 13 September 2007
Deck/Cargo › Ballast › Tank
Issued 1 May 2006 Resolved
Immediately prior to departure from Ingleside, all ballast sensors are to be cleaned and proven to have a deviation of less than the agreed maximum deviation of 4 inches to the satisfaction of the attending ABS surveyor.
Due 7 August 2006
Resolved 6 August 2006
Deck/Cargo › Ballast › Tank
Issued 1 May 2006 Resolved
During all ballasting operations and mooring chain installations, all tank soundings are to be manually strapped, recorded, and entered into the stability program manually. Manual input of ballast tank levels is to continue until such time as the ballast tank sensors can be proven accurate to the satisfaction of the attending ABS surveyor.
Action required: 705 - Other - as specified
Resolved 24 January 2008
Deck/Cargo › Ballast › Tank
Issued 1 May 2006 Resolved
During all ballasting operations and mooring chain installations, all tank soundings are to be manually strapped, recorded, and entered into the stability program manually. Manual input of ballast tank levels is to continue until such time as the ballast tank sensors can be proven accurate to the satisfaction of the attending ABS surveyor.
Action required: 705 - Other - as specified
Resolved 24 January 2008
Deck/Cargo › Ballast › Tank
Issued 1 May 2006 Resolved
Records indicating compliance with the "Verification and Maintenance Procedure for Hull Tank Sensors" will be submitted weekly to ABS surveyor [name withheld] This is to include tank levels and sensor repairs and is to continue after installation of any new sensor to ensure there are no additonal issues.
Action required: 705 - Other - as specified
Resolved 24 January 2008
Deck/Cargo › Ballast › Tank
Issued 1 May 2006 Resolved
Regular updates are to be provided to ABS surveyor [name withheld] on the procurement status and installation schedule of any and/or all new ballast sensors.
Action required: 705 - Other - as specified
Resolved 24 January 2008
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 1 May 2006 Resolved
Make all air receivers available for inspection and provide all information and access required by attending USCG marine inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 13 September 2007
Engineering › Bilge Water Management System › Eductor
Issued 1 May 2006 Resolved
Demonstrate compliance with 46CFR58.60 and 46CFR111.107 for all industrial systems to the satisfaction of attending USCG marine inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 13 September 2007
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 1 May 2006 Resolved
Obtain approval of operating manual and construction portfolio prior to COI.
Action required: 705 - Other - as specified
Resolved 26 July 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 May 2006 Resolved
Obtain USCG approval of Emergency Evacuation Plan IAW 33 CFR 146.140 prior to COI.
Action required: 705 - Other - as specified
Resolved 11 July 2006
Communications › Alarms/Indicators › General Alarm
Issued 1 May 2006 Resolved
Once offshore and operating all machinery/equipment, demonstrate that the general emergency alarm signal produces minimum sound pressure levels above ambient noise levels required by 46 CFR 113.25-12 and 46 CFR 113.50-15 for public address system prior to COI
Action required: 705 - Other - as specified
Resolved 13 September 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 May 2006 Resolved
Verify proper operation of and associated fire fighting equipment for all gas turbines to the satisfaction of the attending USCG marine inspector prior to COI.
Action required: 705 - Other - as specified
Resolved 13 September 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 May 2006 Resolved
Complete all outstanding requirements from "ABS Punch List" dated 11 July 2006 to the satisfaction of the attending ABS surveyor and/or USCG marine inspector as dictated on the punchlist.
Action required: 705 - Other - as specified
Resolved 24 January 2008
Fire Fighting › Fire Main › Pressure
Issued 1 May 2006 Resolved
Prior to departure from Ingleside, hydro test fire main section associated with the ALQ. Also test jockey water pumps.
Due 8 August 2006
Resolved 7 August 2006
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 1 May 2006 Resolved
The actuators that are installed on the Halton fire dampers - Model # Air Tourque AT 101 S12 B - is different than that listed on the BV schedule of approval which lists the Air Torque Model # AT 100 S10 B. Provide manufacturer documentation that the installed AT 101 S12 B actuators do not materially alter the fire rated performance of the damper.
Action required: 705 - Other - as specified
Resolved 21 August 2006

Casualty record · 1

6 March 2011Routine · role: Involved in a Marine Casualty · activity 3985007
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record