Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it35663 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 38 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 38
24 February 2026Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8314977
7 January 2026Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8319839
30 September 2025COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8244874
31 July 2024Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7974983
24 May 2023MTSA Verification · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7695992
9 February 2023Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7650034
1 July 2022Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7500971
7 April 2022Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7428738
21 July 2021Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7263238
13 June 2021Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7264223
5 April 2021Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7168991
26 January 2021Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7130992
8 January 2021Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7122622
27 October 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7085031
17 September 2020Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7068645
21 April 2020Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7341224
20 February 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6912251
17 January 2020Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6881632
10 June 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6709448
31 May 2019Security Plan Review - ASP
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6993448
17 January 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6641885
8 January 2019Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6607795
20 December 2017Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6327004
15 November 2017Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6309903
19 October 2017MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293158
31 August 2017Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6256225
28 August 2017COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6249068
3 April 2017Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6116988
6 March 2017Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6100202
22 August 2016In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5979951
13 July 2016Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5954705
11 July 2016Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5937078
6 July 2016Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5931936
17 June 2016Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5910454
15 June 2016MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913075
15 June 2016Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5922461
8 June 2016Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5902639
15 March 2016Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5834997
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 July 2024Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Observed multiple emergency lights inoperable at lifesaving embarkation decks, stair ways and landings, passageways and means of egress around the facility and its perimeter, near machinery spaces/equipment, at the heli-deck landing area, and more. Restore all emergency lighting on board to a satisfactory and functioning status as initially installed/intended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2024
Resolved 19 August 2024
Resolution: Cleared deficiency after receiving email correspondence with tracking order numbers of lights scheduled for replacement and order numbers.
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 8 January 2021Resolved
Two of the three cranes emergency stops did not work. Emergency stops at the motors did work. Require evidence of all three crane's emergency stops functioning properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2021
Resolved 2 February 2021
Resolution: Received video and closed work order confirming completion of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 January 2020Resolved
01 The emergency equipment provided shall be maintained in good condition at all times. The maintenance required by OEM for lubrication of the falls is not taking place. Cables on #3 LB were rusting. Lubricate all. 33 CFR 146.15. 50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2020
Resolved 4 March 2020
Resolution: Correspondence by compliance lead to remove def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 January 2020Resolved
Main gas turbines #1, 2, and 3 were leaking excessively from the fwd and aft seals on the generator. Windings have significant oil spray. Repair as necessary. Provide proposal to the USCG. 46 CFR 58.10-15. 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2020
Resolved 4 March 2020
Resolution: Correspondence by compliance lead to remove def.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 8 January 2019Resolved
A currently FSP was unable to be provided to the CG Inspector upon request during COI Annual Exam. A valid FSP with updated reivisions approved by the Coast Guard must be onboard at all times. Provide verification that an approved FSP is onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2019
Resolved 29 January 2019
Resolution: Prior to exam completion, upon request by the FSO, the CSO sent an approved FSP with the must up to date revisions by e-mail.
Lifeboat#2 has unreliable packing gland due to it being knocked loose when the break release cable wound around the propeller shaft. Stand-by vsl required to be on scene until weather is adequate for LB#2 launch to ensure reliability of packing gland repair/readjustment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 24 October 2017
Resolution: Received email from Barge Supervisor stating that lifeboat #2 was run ahead in the water with no leaks.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 19 October 2017Resolved
Lifeboat # 1 and 3 had leaking air bottle regulators. Replace/renew to eliminate leakage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 31 October 2017
Resolution: Received email from Barge Supervisor stating that lifeboats' air systems had been corrected.
Washers and Dryers located in TLQs were not secured. Danger of dryer on second level of sliding off onto personnel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 31 October 2017
Resolution: Received email from Barge Sup stating that the dryers had been properly secured.
Handrails on the Northwest column has broken welds and were held together with scaffolding. Renew replace as orginal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 7 December 2017
Resolution: Received email from Marine Team Lead with accompanying pictures showing that the handrails had been repaired.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 19 October 2017Resolved
Fire boundary insulating materials were worn/torn and/or had "dummy pins" in numerous areas. Repair and replace to restore required fire protection IAW vsls fir control plan (DWG#1440-50-SA-DG-070-5504)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 December 2017
Resolution: Received email from [name withheld] the Barge Supervisor of Atlantis that all insulation identified as torn during the inspection had been repaired. This clears the last outstanding 835 that Atlantis had opened.
Several liferafts have stowage height of 25 meters and the unit's current draft is at least 26 meters. Ensure liferafts are stowed at required height limits or replace liferafts with ones that canmeet the stowage height.
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 23 June 2016
Resolution: Recieved email with accompanying pictures showing that this deficiency had been cleared.
Lifesaving › Lifeboat › Propulsion Engine
Issued 15 June 2016Resolved
Lifeboat # 4 has an idling issue due to a faulty fuel pump manufactured by Lister. Ensure fuel pump is replaced/repaired to original condition and idle issue is corrected.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 23 June 2016
Resolution: Recieved email with accompanying pictures showing that this deficiency had been cleared.