Records from 2017 to 2026. Most recent: inspection, 3 June 2026.
Documentation record
Registered dimensions (L × B × D)39.0 ft × 8.5 ft × 5.0 ft
Registered tonnagegross 13 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOOL AMPHIBIOUS MANUFACTURERS INTERNATIONAL · SOUTH LIMA, NY, UNITED STATES · built 2004
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeBox
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 41
3 June 2026
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8390225
21 May 2026
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8377781
1 March 2026
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8345079
4 August 2025
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8214170
3 August 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8208376
28 July 2025
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8197753
28 July 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284424
25 July 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284421
24 July 2025
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8194345
22 July 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8191621
14 July 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8186349
14 July 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8188878
25 June 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8166532
1 August 2024
Deficiency Check · Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7972567
28 December 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7842922
27 July 2023
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7754139
27 July 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7790194
12 June 2023
Deficiency Check · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7687072
6 June 2023
Administrative Inspection · Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7758059
16 December 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7369817
1 December 2021
Examination of Repairs · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7383383
13 July 2021
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7255337
5 March 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7185684
18 November 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7098142
8 November 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7092053
8 November 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7100884
22 September 2020
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7063401
22 September 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7068063
1 August 2019
Annual Inspection · Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6769394
18 July 2019
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6755088
18 July 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6759060
5 September 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6533304
30 July 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6495533
22 April 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6396563
26 March 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6378817
24 March 2018
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6379143
12 December 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323356
6 December 2017
Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6319514
4 December 2017
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6317739
17 November 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6310183
27 July 2017
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6222820
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 July 2025
Resolved
Vessel's steering experienced a failure while underway with passengers. Make proper repairs and perform underway sea trial with attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2025
Resolution: Steering gear system was replaced with a new system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 July 2025
Resolved
Vessel experienced loss of steering while underway with passengers. This is the third loss of steering with an older steering system, vessel is to install the approved system that was installed on the sister vessels and conduct propulsion tests in the presence of a USCG Marine Inspector prior to getting underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2025
Resolution: Observed repairs and performed sea trails in Mission Bay, SD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2025
Resolved
A vessel must be provided with steering gear that is of adequate strength and capable of steering the vessel at all services speeds. Vessel reported a loss of steering. Provide technician report to local OCMI. Prior to carrying passengers a sea trail must be conducted in the presence of a Marin Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2025
Resolution: [name withheld] attended vessel to conduct an underway steering test. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 August 2024
Resolved
One cracked weld was found on the starboard side, mid ship side of hull above waterline.
Repair within 14 days and send pictures of the repair to [email withheld]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
Resolution: Received documentation that the weld has been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 December 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced loss of propulsion while underway with passengers. Vessel operator must determine cause of failure, make necessary repairs and conduct propulsion tests in the presence of a USCG Marine Inspector prior to getting underway with passengers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2024
Resolution: Witnessed a satisfactory test of the propulsion system.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 1 August 2023
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel undertook various alterations affecting stability. Vessel is required to submit a plan for conducting a new Simplified Stability Test for OCMI approval.
Cites: 46 CFR 176.700(d); 46 CFR 178.310; 46 CFR 170.120.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2023
Resolved 28 September 2023
Resolution: New Stability Letter was signed 20 September 2023.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 July 2023
Resolved
On Vessel reported a loss of steering / maneuverability near the shelter island pier. Vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds and be capable of moving the rudder from 35 degrees on one side to 30 degrees on the other side in not more than 28 seconds with the vessel moving ahead at maximum service speed.
Vessel must troubleshoot and identify the cause of the loss of steering, submit a technicians report attesting to the cause as well as satisfactory operation of the propulsion and steering system and make the vessel available for inspection to the local OCMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
Resolution: Installed new steering ram.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 June 2023
Resolved
Vessel does not have a valid FCC Safety Radiotelephony Certificate. Provide a valid FCC Safety Radiotelephony Certificate for the vessel.
Cite: 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 10 July 2023
Resolution: Received a scan of the new cert.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 14 July 2021
Resolved
DAPI information not available for inspection. Provide DAPI employee information to marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 21 July 2021
Resolution: documents sent via email...[name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2020
Resolved
To maintain a valid Certificate of Inspection, vessel must complete its annual inspection within the specified periods and your Certificate of Inspection must be endorsed.
Vessel missed 2019 and 2020 annual inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2020
Resolved 2 December 2020
Resolution: Completed Satisfactory Annual Inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 November 2020
Resolved
Identify the cause of main engine shutdown. Prove proper operation of main engine. Due prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2020
Resolution: Cooling fan bearing and belt replaced, tested SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 November 2020
Resolved
Conduct Certificate of Inspection prior to carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2020
Resolution: COI completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 September 2020
Resolved
Prove proper operation of outboard drive system prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Repairs were made to outdrive and underway test was conducted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 August 2019
Resolved
Re-weld port side, aft ballast mount rail to hull at crack.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2019
Resolved 14 August 2019
Resolution: Welded ballast rail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 August 2019
Resolved
Prove proper operation of port side bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 August 2019
Resolution: Serviced check valve, ops tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 July 2019
Resolved
Determine cause of loss of marine gauges, VHF radio and marine drive gear. Make repairs to satisfaction of attending marine inspector prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2019
Resolved 19 July 2019
Resolution: Loose circut breaker connector terminals replaced.
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 22 April 2018
Resolved
Prove proper operation of engine cooling system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2018
Resolved 29 May 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 24 March 2018
Resolved
Loss of propulsion/engine overheat caused by seized idler pulley on serpentine belt
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2018
Resolved 30 March 2018
Engineering › Freshwater System (piston cooling) › Storage Tank
Issued 6 December 2017
Resolved
Radiator overflow cap is OOC. Prove proper op of cooling system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2017
Engineering › Steering Gear System › Solenoid Valve
Issued 4 December 2017
Resolved
Solenoid valve stopped working cause=ing vessel to lose primary steering.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2017
Resolved 4 December 2017
Resolution: New solenoids installed. Steering tested and functions.