Documentation record
Registered dimensions (L × B × D)125.7 ft × 37.7 ft × 12.6 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)125.7 ft × 37.7 ft × 12.6 ft
ITC tonnagegross 541 / net 174
BuilderDAKOTA CREEK INDUSTRIES INC · ANACORTES, WA, UNITED STATES · built 2004
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBREMERTON, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
541 - Convention (Subpart B), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
174 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
7 May 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8326888
30 October 2025
Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8258426
29 May 2025
Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8260973
1 May 2025
Administrative Inspection · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8130213
25 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8103966
22 June 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7940383
1 May 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904975
25 April 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7901096
2 April 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888936
14 March 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7876846
21 February 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7875336
9 June 2022
Examination of Repairs · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7492504
22 November 2021
Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7344995
14 July 2020
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7006011
7 February 2020
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904664
28 October 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6843794
3 September 2019
Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6802418
11 July 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6746584
2 July 2019
Internal Structural Exam · Administrative Inspection · DAPI Audit · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6725318
17 April 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6664960
17 April 2019
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6665046
3 October 2018
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6549178
12 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538714
8 August 2018
Damage Survey · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6505041
25 January 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6349708
17 November 2017
Deficiency Check · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6308636
11 October 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6285439
22 September 2016
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6005357
1 August 2016
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5959936
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended.
Port main engine installed on the vessel is not suitable for the purpose intended as indicated by a low coolant alarm and a leak of coolant into the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2024
Resolved 28 June 2024
Resolution: Gaskets on port engine heat exchanger replaced. Dock trials sat. Port engine operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2024
Resolved
Quanitity of lifejackets not labeled ivo stowage compartments
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2024
Resolved 14 March 2024
Resolution: Life jacket quantity properly displayed. All Sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2022
Resolved
Fire load calculations must be submitted by the owner for review to the Marine Safety Center when: The cognizant OCMI determines, based on the quantity of combustibles, that the fire load present in a high risk accommodations space may exceed 37.5 kg (7.5 pounds) of combustibles per square meter (square foot) of deck area. The passenger cabins had extensive furnishings replace, shipyard has not submitted fire load calcs. to MSC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2024
Resolution: Def open due to admin oversight. Resolved due to length of time and context of def w/ current operation of vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2022
Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2024
Resolution: Def open due to admin oversight. Resolved due to length of time and context of def w/ current operation of vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 July 2020
Resolved
EACH VESSEL MUST HAVE ADEQUATE EMERGENCY LIGHTING FITTED ALONG THE LINE OF ESCAPE TO THE MAIN DECK FROM ALL PASSENGER AND CREW ACCOMODATION SPACES LOCATED BELOW THE MAIN DECK. THE EMERGENCY LIGHTING MUST AUTOMATICALLY ACUTUATE UPON FAILURE OF THE MAIN LIGHTING SYSTEM. MI FOUND 01 EMERGENCY LIGHTS TO BE INOPERABLE ONCE VESSEL TESTED ALL EMERGENCY LIGHTS FOUND ONBOARD.
46 CFR 120.432(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 15 July 2020
Resolution: Received photograph of repaired emergency light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 February 2020
Resolved
Exhaust gas must not leak from the piping or any connections. Port side engine room generator exhaust piping has a soft patch on the piping leading overboard. Permanently repair the soft patch and replace the adjacent leaking gasket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 April 2020
Resolution: Corroded section of exhaust piping was permanently repaired with welding.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 July 2019
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Large pit witnessed on starboard side engine room bilge discharge line. Vessel must make permanent repairs to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 25 July 2019
Resolution: Operator submitted photos of the bilge discharge line being cropped out and new line installed with permenant connection.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 2 July 2019
Resolved
The dimensions of a means of escape must be such as to allow easy movement of persons when wearing life jackets. There must be no obstructions in means of escape that could cause injury, ensnare clothing, or damage life jackets. Escape route in open deck aft stairway lead to secured door at bottom of stairway, preventing clear means of escape. Vessel must keep stairway escape route clear and open at all times.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 July 2019
Resolved 2 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 July 2019
Resolved
The vessel must test each fire hose to a test pressure equivalent to its maximum service pressure. Leaking witnessed at fire station #3 fire hose during test. Vessel must replace fire hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 July 2019
Resolved 2 July 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 July 2019
Resolved
Vessel must conduct a satisfactory operational test of all emergency electrical systems. Vessel emergency lighting located at stbd side embarkation area was not operational. Vessel must repair/replace light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 3 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2018
Resolved
HVAC space missing insulation on ceiling. Space is required to have insulation per fire boundary classification on fire plan. Provide insulation to portion of ceiling exposed. 46 CFR 116.415 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 29 October 2018
Resolution: Insluation installed in the HVAC space to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 October 2018
Resolved
Life ring label faded and unreadable. Provide clear labeling on life ring on 2nd deck. 46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 October 2018
Resolved 29 October 2018
Resolution: Life ring lables replaced to the satisfaction of the Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 October 2019
Resolution: Verified AIS error has been corrected for incorrect draft.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 31 January 2018
Resolved
Crop and renew stbd MDE cooling water piping currently repaired with doubler.
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 13 March 2018
Resolution: Pipe cropped and renewed.
Engineering › Bilge Water Management System › Piping
Issued 11 October 2017
Resolved
Vessel is unable to obtain suction from starboard bilge system. 46 CFR 119.500
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2017
Resolved 12 October 2017
Resolution: Repaired piping and demonstrated proper operation of bilge system.
Engineering › Bilge Water Management System › Piping
Issued 11 October 2017
Resolved
Vital Systems piping has multiple unathorized piping repairs utilizing either gasketed mechanical couplings or flexible pipe couplings. Portions of piping were previously repaired with dissimiliar metals.46 CFR 119.710, 46 CFR 56.60, 46 CFR 56.30-35, 46 CFR 56.30-40.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 31 January 2018
Resolution: (19) Vital water system hose/gasketed mechanical coupling connections replaced with welded flanges.
Construction/Loadline › Structures › Trunk
Issued 11 October 2017
Resolved
Port and Starboard Engine Room Stainless Steel hatch and trunk has no insulation and appears too thin to meet the Engine Room A-0 boundary requirement. 46 CFR 116.14 (a), NVIC 09-97
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 1 November 2018
Resolution: Port and Starboard Engine Room hatches were replaced with 1/4 in. steel hatches that meet the A-0 requirement for the space.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 11 October 2017
Resolved
Exhaust Leak in Exhaust Piping in the Jet Room near the forwared bulkhead. 46 CFR 119.430 (b)
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 31 January 2018
Resolution: Exhaust flange replaced.
Engineering › Pressure Vessel › Support
Issued 11 October 2017
Resolved
Hot Water heater is not strapped down. 46 CFR 119.320
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 31 January 2018
Resolution: Water heater strapped down.
Construction/Loadline › Structures › Door
Issued 11 October 2017
Resolved
A/C Room Door is an A-0 boundary and has a vent cut out in the bottom of the door. 46 CFR 116.435
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 31 January 2018
Resolution: Operator proved door is C' and added steel plate over vent to repair.