Records from 2004 to 2026. Most recent: inspection, 2 July 2026.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 14.5 ft × 7.8 ft
Registered tonnagegross 59 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINETTE MARINE CORP · MARINETTE, WI, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Simplified, Gross Ton
47 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
2 July 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8425947
23 April 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8120101
25 February 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8084341
5 June 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7929868
18 April 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7671177
17 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7409006
4 February 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7391004
16 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7227375
12 August 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7036558
17 April 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6668366
5 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6620864
28 March 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6381855
1 May 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6129885
25 April 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6132359
23 March 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6106657
16 December 2015
COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5773121
28 March 2014
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4825943
27 March 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4822007
26 July 2012
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4391204
8 June 2012
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4337604
30 May 2012
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4328202
5 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4145934
10 December 2010
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3908110
9 March 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3430085
24 April 2008
Hull Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3191916
4 April 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2902428
31 May 2006
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2659461
19 January 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2568093
7 June 2005
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2388797
29 April 2004
Deficiency Check · Simplified Stability Test · Hull Examination · Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2055925
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 May 2022
Resolved
46 CFR 180.137 (b)(1) - The float-free link required by 46 FR 180.130(a)(1) must be: of proper strength for the size of the life float as indicated on its identification tag. Vessel was missing the identification tag for the float-free link.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2023
Resolution: Verified Tag for Lifefloat weaklink
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 June 2021
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port MDE drip-less shaft bearing was found to be leaking. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 6 July 2021
Resolution: Received photos of new dripless shaft bearing installed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 March 2014
Resolved
Did not conduct MOB and fire drills. Conduct drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2014
Resolution: Successfully conducted man overboard and fire drills.
Engineering › Bilge Water Management System › Pump
Issued 27 March 2014
Resolved
Lazarette bilge pump not operational. Prior to carrying passengers, perform satisfactory testing to attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2014
Resolution: Vessel Owner replaced lazarette bilge pump with same brand/model bilge pump (Lovett 1200 bilge pump); all sat.
Fire Fighting › Ventilation Systems › Ducts
Issued 27 March 2014
Resolved
Four engine room vent closures missing. Prior to carrying passengers, install closure devices to the satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2014
Resolution: Installed satisfacotry closure devices on four engine room vent closures with 06 removable alluminum plates; all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 March 2014
Resolved
Battery has no proof of expiration. Replace with new batteries. Restricted to day time ops.
Action required: 705 - Other - as specified
Resolved 28 March 2014
Resolution: Vessel Master installed new batteries with expiration date for Lifefloat waterlight; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 March 2014
Resolved
Life buoy battery has no proof of expiration. Replace with new; restriced to day time operation.
Action required: 705 - Other - as specified
Resolved 28 March 2014
Resolution: Vessel Owner/Captain installed new batteries with the expiration date labeled for the lifebouy waterlight; all sat.
Engineering › Bilge Water Management System › Piping
Issued 27 March 2014
Resolved
Vessel's bilge hose for the fixed bilge pump (non-submersible) is not the required hose. Replace all hose associated with the non-submersible bilge pumps with USCG A1, A2, B1or B2 hose or with SAE J-1942 hose not including non-vital water (NVM) rated hose.
Action required: 705 - Other - as specified
Due 28 April 2014
Resolved 29 April 2014
Resolution: Vessel replaced hoses with USCG A2 type to the satisfaction of the CG Inspector. All sat.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 27 March 2014
Resolved
High temperature visual warning device for exhaust cooling system not operational. Prior to carrying passengers, make repairs to the satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2014
Resolution: Master proved satisfactory operation on visual warning device for exhaust cooling system; all sat.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 27 March 2014
Resolved
Battery box cover is missing. Replace with sufficient cover to the satisfaction of attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 28 April 2014
Resolved 29 April 2014
Resolution: Operator placed a battery box cover over the batteries to the satisfaction of the CG Inspector. All sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 April 2008
Resolved
Vessel owner did not make vessel available for annual exam within the 90 day window.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2008
Resolved 24 April 2008
Resolution: Vessel''''s annual exam was completed and COI was endorsed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 4 April 2007
Resolved
Service CO2 bottle for fixed engine room fire fighting service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2007
Resolved 6 April 2007
Resolution: Cylinder and valve serviced by Hiller Systems Inc.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 19 January 2006
Resolved
Weight test required for CO2 bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2006
Resolved 20 January 2006
Lifesaving › Lifefloat › Float-free Link
Issued 19 January 2006
Resolved
Provide weak link for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2006
Resolved 23 January 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 January 2006
Resolved
Provide three Type I lifejackets for children onboard prior to carrying children and nlt 19 Feb 06. Vsl has three type II lifejackets for children on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2006
Resolved 3 February 2006
Construction/Loadline › Structures › Door
Issued 29 April 2004
Resolved
Vessel limited to carrying not more than 6 passengers for hire until an acceptable equivalency to the permanent closure of the bow door has been approved by the [name withheld] and implemented on the vessel.
Due 30 June 2005
Resolved 7 June 2005