← All vessels
BEACON
BEACON is a 1991 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in May 2026, along with 65 deficiencies, 1 operational control and 1 casualty investigation in 2017.
Records from 2016 to 2026. Most recent: inspection, 20 May 2026.
- Built
- 1991
- Last inspected
- 20 May 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 65 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2017
Identity
1155512
WD16216
678438
Flag
UNITED STATES
Maury page id
psix-678438
Inspections, by type
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 14.9 ft × 6.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC · ANAHEIM, CA, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 27 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 21
20 May 2026
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8357049
28 May 2025
In-Service Inspection · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8115964
5 March 2025
Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8089044
6 February 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7861650
24 January 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7625724
13 December 2022
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631246
8 February 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7392450
11 March 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7154566
12 November 2020
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7093897
23 March 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6930706
18 September 2018
DAPI Audit · Annual Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6542972
25 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6344468
7 November 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6302793
24 July 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6220628
20 June 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6184713
11 June 2017
Damage Survey · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6173279
11 June 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6190540
1 June 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6162734
8 September 2016
Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5995542
22 April 2016
Administrative Inspection · Deficiency Check · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5860099
19 January 2016
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5799937
Deficiency record · 65
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 May 2025
Resolved
Wire connectors utilized in conjunction with screw type terminal blocks must be of the captive type such as the ring or the flanged spade type. Electrical connectors on neutral bus not authorized.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2025
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 C (150 F), must be suitably insulated where necessary to prevent injuries. Lag exhaust section ahead of water intake.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 May 2025
Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Insufficient packing for bulkhead penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 May 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) three hand red flare distress signals approved in accordance with 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) three hand orange smoke distress signals approved in accordance with 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Operator missing one orange smoke signal.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 March 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural at least once every two years. Vessel shall conduct dry dock examination in conjunction with certificate of inspection. Vessel is restricted from carrying passengers until completion of dry dock examination.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel did not have first aid kit onboard. Place first aid kit onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 7 February 2024
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Designated supervisor did not have supervisory training. Receive training.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 February 2024
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. 04 child lifejackets had worn retro reflective tape. Renew tape on identified lifejackets, vessel restricted from carrying child passengers unless appropriate lifejackets are onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2024
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Lifering's grab line was deteriorated. Replace grab line.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 February 2024
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel does not have emergency broadcast instructions. Place emergency broadcast instructions at radio station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2024
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads. FWD bilge pump and operating station indicator light was not operational. Repair bilge pump and indicator light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 February 2024
Resolved
A power-driven vessel underway shall exhibit a masthead light forward and a sternlight. Vessel's masthead light (anchor light) was not operational. Repair light. Vessel is restricted to daylight operations only and is prohibited from operating in restricted visibility
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 24 January 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard condition. Vessel did not have emergency instructions onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 January 2023
Resolved
A vessel on lakes, bays and sounds, or rivers route must carry: three hand red flare distress signals. Vessel was missing two red flares.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 January 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Signage prohibiting passengers from upper deck was damaged and is required to be replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 January 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel was missing light at operating stand.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2023
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy markings are faded and need to be relabeled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of the fire bucket's lanyards was significantly deteriorated and requires replacement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 March 2021
Resolved
A hatch exposed to weather must be watertight. Gasket on chain locker hatch is worn. Replace gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 March 2021
Resolved
Flares must be stowed in a portable watertight container. Container onboard is not watertight. Provide watertight container.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2021
Resolved
Each type I life jacket must be marked with type I retroflective material. Existing tape is worn on 4 life jackets. Replace retroflective tape.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 March 2020
Resolved
Emergency escape hatch was not adequately secured, port aft portion of hatch was separating from superstructure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2020
Resolved
Bracket securing ventilation in engine room was broken. Replace bracket and adequately secure ventilation closure.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 March 2020
Resolved
Vessel's Radiotelephony certificate expired in February. Informed owner/operator of requirements and guidelines for replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2020
Resolved
Life jacket stowage was not labeled in accordance with CFR requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2020
Resolved
Engine fuel filters were not equipped with drip pan or flame shield.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 December 2017
Resolved
Replace eye wash.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 December 2017
Resolved
Place copy of current drug consortium letter onboard along with consortium policy.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 December 2017
Resolved
Replace 01 adult life jacket.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 December 2017
Resolved
Replace coursing to ladder for flying bridge access and place no passenger sign.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 11 June 2017
Resolved
Install new approved pre-engineered fixed gas fire extinguishing system prior to carrying passengers.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 11 June 2017
Resolved
Replace wasted belt in way of water cooling system.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 June 2017
Resolved
Need supervisor training. IAW 46 CFR 16
Documentation › Logs/Records › Logbook (official)
Issued 7 June 2017
Resolved
Log daily radio checks. IAW 46 CFR 184.502
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 June 2017
Resolved
Need 01 Alcohol test strip. IAW 46 CFR 16.240
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2017
Resolved
Need Aspirin and ammonia inhalants for first aid kit. IAW 46 CFR 184.710
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 June 2017
Resolved
Need Coast Pilot [name withheld] and tides. IAW 46 CFR 184.420
Electrical › Electrical Distribution System (service) › Cable
Issued 7 June 2017
Resolved
Wires under pilot house need wire supports. IAW 46 CFR 183.340
Engineering › Fuel Oil Service System › Tank
Issued 7 June 2017
Resolved
Both fuel fills need to be bonded. IAW 46 CFR 182.455
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 7 June 2017
Resolved
Generator starting battery needs to have permanent type connections; remove wing nuts. IAW 46 CFR 183.350
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 June 2017
Resolved
Repair/replace anchor, port and FWD masthead lights. IAW 46 CFR 183.420
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 7 June 2017
Resolved
Generator derated placard posted on generator and generator derated at 80%. IAW 46 CFR 183.320(b)(2)
Stability › Watertight Integrity › General
Issued 5 December 2016
Resolved
In accordance with standards acceptable to the cognizant OCMI as good marine practice IAW 46 CFR 176.800, Re-seal back up rudder in the aft corner & reseal four screw holes on upper deck aft SBD corner. Correct by 16DEC16.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 12 February 2016
Resolved
Provide one B-I portable fire extinguisher for machinery space; locate just outside exit IAW 46 CFR 181.500
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 February 2016
Resolved
Provide approved first aid kit IAW 46 CFR 184.710 (First aid kit onboard had items missing and was not water-tight)
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 February 2016
Resolved
Remove all flammable material from accommodation spaces IAW 46 CFR 147.45(b)
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 February 2016
Resolved
Label emergency exit (on vessel’s bow) on both sides IAW 46 CFR 185.606
Engineering › Bilge Water Management System › Pump
Issued 12 February 2016
Resolved
Replace fwd bilge pump under accommodation space with approved bilge pump IAW 46 CFR 182.520
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 February 2016
Resolved
Remove or properly cap and enclose in a junction box dead end wires under benches in cabin (both sides), lazarette, and under console IAW 46 CFR 183.200
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 February 2016
Resolved
Properly secure all sagging/hanging wires in lazarette, under accommodation space, forepeak IAW 46 CFR 183.200
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 12 February 2016
Resolved
Properly attach storm rail on port bow by forepeak tank/space IAW 46 CFR 177.920
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 February 2016
Resolved
Properly label all lifejacket stowage locations with adult or child and quantity IAW 46 CFR 185.604(f)
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 February 2016
Resolved
Properly separate adult and child life jackets IAW 46 CFR 180.78
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 12 February 2016
Resolved
Replace or remove trash cans. Replace with non-combustible cans IAW 46 CFR 177.405(f)
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 12 February 2016
Resolved
Add mousing/securing wire on all shackles IAW 46 CFR 184.300
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 February 2016
Resolved
Make bulkheads in engine room vapor tight IAW 46 CFR 177.405
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 12 February 2016
Resolved
Provide updated DAPI (Drug and Alcohol prevention) letter, employee assistance program information and training IAW 46 CFR 16.401
Documentation › Certificates/Documents › FCC SSL
Issued 12 February 2016
Resolved
Provide current FCC station license IAW 47 CFR 80.13
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 February 2016
Resolved
Provide current FCC safety radiotelephony certificate IAW 47 CFR 80.59
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 February 2016
Resolved
Provide rails/guards not more than 12" apart on tower and at top of ladder to upper deck not more than 4" apart IAW 46 CFR 177.900
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 February 2016
Resolved
Replace stern light (burned out) IAW 46 CFR 183.420
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 12 February 2016
Resolved
Lock MSD valve in closed position when not pumping at a shore facility IAW 33 CFR 159
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 February 2016
Resolved
Repair/replace oil pressure gauge at operating station in cabin IAW 46 CFR 182.410(b)
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 12 February 2016
Resolved
Engine RPM, Jacket water temperature, and lube oil pressure gauges must be provided for (readily visible) at the operating station at the vessels "tower" operating station, the "tower" operating has no gauges IAW 46 CFR 182.410
Operations/Management › Passenger Operations › Safety Orientation
Issued 12 February 2016
Resolved
No passengers shall be allowed on the vessels second deck, atop the cabin roof, unless or until proof is provided (via stability letter/testing) to allow such IAW 46 CFR 178.210
Casualty record · 1
11 June 2017Routine · role: Involved in a Marine Casualty · activity 6190540
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
DOLPHIN FUN (2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.