← All vessels
GASCHEM BALTIC
GASCHEM BALTIC is a 2004 tank ship. The Coast Guard has recorded 32 inspections since 2004, most recently in August 2021, along with 11 deficiencies and 12 operational controls.
Records from 2004 to 2021. Most recent: inspection, 10 August 2021.
- Built
- 2004
- Last inspected
- 10 August 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9269269 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8EC3
679352
Flag
LIBERIA
—
Maury page id
psix-679352
Inspections, by type
…with no type recorded9
Years with a record
14 calendar years (2004–2021)
The 32 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7208 - Convention (Subpart B), Gross Ton
9157 - Dead Weight, Metric Ton
13824 - Displacement, Metric Ton
2204 - Convention (Subpart B), Net Ton
9157 - Dead Weight, Metric Ton
13824 - Displacement, Metric Ton
2204 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 32
10 August 2021
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7282449
6 August 2021
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7279484
29 July 2021
PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7265355
1 December 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7104076
17 November 2020
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7096818
26 May 2020
COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6953092
13 August 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6239142
23 November 2016
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6042193
3 August 2015
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5198022
22 August 2014
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 4962702
14 August 2014
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4954705
7 July 2012
Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4370480
10 October 2010
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3867026
5 April 2009
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3446568
2 April 2009
ISPS I Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3444888
25 May 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3216166
27 September 2007
Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-GAS Annual · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3067397
20 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2935405
10 April 2007
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2905092
14 February 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2872153
29 September 2006
COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2790262
28 September 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2789407
16 February 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2586652
21 October 2005
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2519516
8 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2422624
5 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2415846
2 July 2005
Ballast Water Examination · COC-GAS Annual · ISPS III Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2411276
20 February 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2305205
8 October 2004
Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2216806
13 August 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2165136
8 June 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2092304
1 May 2004
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2056737
Deficiency record · 11
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the
provisions of the present regulations to ensure that the ship in all respects will remain fit to
proceed to sea without danger to the ship or persons on board.
Vessel experienced, prior to departing, equipment failure on the two three way valve on the main engine. you are required to submit a classification society report to [email withheld] attesting to the cause of the equipment failure, that authorized temporary or permanent repairs have been completed, and that the vessel's full main engine function has been restored.
74 SOLAS (14) I/11(a)
60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 December 2020
Resolved
Whenever...a defect is discovered which affects the safety of the ship or completeness of its equipment. The Master shall report to the Administration...Recognized Organization responsible for issuing the relevant certificate who shall cause investigations to be initiated to determine whether a survey, as required by regulations 7,8,9 or 10 is necessary. Currently the vessel experienced an intermittent loss of pitch control inbound the port of Houston. A Class report/Survey of completed repairs will be required to clear deficiency. Shift to City Docks Dock 42 with 02 tugs as discussed, is allowed. SOLAS 74(2014 Cons Ed)/1/11(c) 60(a)(c).
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (air motor)
Issued 27 September 2007
Resolved
27SEP2007-Vessel's secondary means of starting the emergency generator is inoperable.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 29 September 2006
Resolved
Wiring entering emergency generator space is not installed or supported. Rectify to the satisfaction of class prior to next US port after sailing foreign.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 29 September 2006
Resolved
Gas plant area has PPM concentrations in excess of established TLV's. Class on behalf of the Administration, is to provide a report detailing the nature of the continuing vapor release, and corrective actions to be taken to ensure the space is considered, "Safe for Workers" Prior to departure, class to attest to repairs made, and issue a report of survey , to be provided to the OCMI approval.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 29 September 2006
Resolved
Sprinkler head of deck spray system on the forward end of deck tank is not spraying.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 29 September 2006
Resolved
Sprinkler head of deck spray system for port side bridge level windows have no spray, or reduced spray.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 September 2006
Resolved
Emergency generator has a leak in jacket water system. Rectify to the satisfaction of class prior to next US port after sailing foreign.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 September 2006
Resolved
Vessel publications do not include 46 CFR 140 to 155. Rectify to the satisfaction of Coast Guard within 14 days.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 September 2006
Resolved
Doors fitted in boundary bulkheads of machinery space not reasonably gas tight and self closing.
Deck/Cargo › Inert Gas System › Venting System
Issued 2 July 2005
Resolved
The PSA Nitrogen Generator Space in not fitted with an Oxygen alarm as per IACS unified requirements. Provide a class report attesting to a satisfactory arrangement or procedure by 02 August 2005.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.