MAURY USCG vessel records Sign in
← All vessels

CLEAN ENERGY

CLEAN ENERGY is a 2004 offshore supply vessel. The Coast Guard has recorded 32 inspections since 2004, most recently in July 2026, along with 22 deficiencies.

Records from 2004 to 2026. Most recent: inspection, 3 July 2026.

Built
2004
Last inspected
3 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9315513 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
680870
Flag
VANUATU
366947110 (licence lapsed)
Maury page id
psix-680870

Inspections, by type

…with no type recorded3
Years with a record 16 calendar years (2004–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2929 - Dead Weight, Metric Ton
2045 - Convention (Subpart B), Gross Ton
4504 - Displacement, Metric Ton
797 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD3649MMSI 366947110 · cancelled · compulsorily equipped · granted 27 May 2016, cancelled 16 April 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDB7727MMSI 366947110 · cancelled · compulsorily equipped · granted 14 May 2004, cancelled 8 August 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

3 July 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8385754
5 May 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8367263
21 April 2023 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7670021
27 April 2022 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7439338
15 October 2021 PSC A
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7333312
13 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7002091
26 August 2019 Annual Inspection · ACP Annual Oversight · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6794761
19 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6645521
14 November 2018 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6580285
1 November 2017 MTSA/ISPS Verification · Deficiency Check · ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6299167
27 March 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6112594
20 October 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6026673
1 September 2016 Periodic Inspection · MTSA/ISPS Verification · ACP Periodic Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5989937
12 November 2015 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5761902
27 August 2014 ACP COI Oversight · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4966862
27 July 2009 Administrative Inspection · MARPOL Annex VI Survey · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3547824
14 October 2008 ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3344173
23 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330704
18 September 2006 Re-Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2783156
6 September 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2770498
4 August 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2739865
7 March 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2597925
2 December 2005 ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2546830
14 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2426318
7 June 2005 MARPOL Annex II Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2382920
2 February 2005 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2285424
10 January 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2272007
14 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2220724
3 September 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2241975
27 August 2004 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2178405
2 July 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2118618
17 May 2004 MTSA Verification · Construction Oversight · ACP COI Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2070261

Deficiency record · 22

03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 August 2019 Resolved
Provide proper operation of stbd aft watertight hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2019
Resolution: Corrected to the satisfaction of ABS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 August 2019 Resolved
Provide proper operation of port aft watertight hatch gasket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2019
Resolution: Corrected to the satisfaction of ABS.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2019 Resolved
Provide proof of valid batteries for life ring lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 30 August 2019
Resolution: Corrected to the satisfaction of ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2019 Resolved
Provide proper working condition of emergency generator fuel lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 30 August 2019
Resolution: Corrected to the satisfaction of ABS.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 August 2019 Resolved
Provide proper installation of CO2 hose on paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2019
Resolution: Corrected to the satisfaction of ABS.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 August 2019 Resolved
Provide proper installation of fixed CO2 hose in CO2 room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2019
Resolution: Corrected to the satisfaction of ABS.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2019 Resolved
Properly secured fuel sample storage bin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 30 August 2019
Resolution: Corrected to the satisfaction of ABS.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 November 2017 Resolved
perform fire and man overboard drills (utilizing the rescue boat) to the satisfaction of the attending CG Marine Inspector and prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2017
Electrical › Electric Generation Source (emergency) › Generator
Issued 27 July 2009 Resolved
Provide secondary means of starting the emergency generator as per SOLAS II-1 reg 44 to the satisfaction of class. Provide to the Coast Guard a Class report proving compliance.
Due 19 September 2009
Resolved 21 September 2009
Resolution: ABS attended and signed off.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 September 2006 Resolved
INSTALL HANDRAIL PORT STERN.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 19 October 2006
Resolution: COMPLETED.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 18 September 2006 Resolved
REPAIR RING BOUYS AS DISCUSSED (STENCIL, REMOVE DUCT TAPE, ATTACHE LINES AND SMOKES AROUND BODY OF RING.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 18 September 2006 Resolved
PROVIDE AND POST TRANSFER PROCEDURES FOR F/O, MUD.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Deck/Cargo › Cargo Stowage › General
Issued 18 September 2006 Resolved
POST CRANE INSTRUCTIONS/HAND SIGNALS AT CRANE.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 September 2006 Resolved
INSTALL BREAKER COVERS IN PANEL L101 & EP101.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Fire Fighting › Fire Hoses › Condition
Issued 18 September 2006 Resolved
RENEW STARBOARD SIDE FIRE HOSE.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 18 September 2006 Resolved
STENCIL ALL VALVES ON MAIN DECK
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Communications › Alarms/Indicators › General Alarm
Issued 18 September 2006 Resolved
DEMONSTRATE PROPER OPERATION OF GENERAL ALARM IN PORTABLE QUARTERS AND INSTALL SMOKE DETECTOR AND CONNECT TO VSL FIRE ALARM PANEL.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 September 2006 Resolved
PAINT SIDE RUNNING LIGHT BACKGROUND MATTE BLACK.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 18 September 2006 Resolved
DEMONSTRATE PROPER OPERATION OF BOAT DAVIT.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 19 September 2006
Resolution: COMPLETED
Communications › Alarms/Indicators › Fire Alarm
Issued 2 February 2005 Resolved
DEMONSTRATE PROPER OPERATION OF THE PORTABLE QUARTERS FIRE DETECTION SYSTEM.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2005
Resolved 2 February 2005
Communications › Alarms/Indicators › General Alarm
Issued 2 February 2005 Resolved
DEMONSTRATE PROPER OPERATION OF THE GENERAL ALARM IN THE PORTABLE QUARTERS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2005
Resolved 2 February 2005
Communications › Internal Communications System › Sound-powered Telephone
Issued 2 February 2005 Resolved
DEMONSTRATE PROPER OPERATION OF COMMUNICATIONS BETWEEN PORTABLE QUARTERS AND PILOT HOUSE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2005
Resolved 2 February 2005

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.