CARIBE ROSA is a 2004 tank ship. The Coast Guard has recorded 44 inspections since 2004, most recently in April 2019, along with 48 deficiencies and 7 operational controls.
Records from 2004 to 2019. Most recent: inspection, 30 April 2019.
- Built
- 2004
- Last inspected
- 30 April 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 48 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9286451 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5MR2
681144
Flag
LIBERIA
—
Maury page id
psix-681144
Inspections, by type
…with no type recorded9
Years with a record
14 calendar years (2004–2019)
The 44 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6522 - Regulatory (Subpart C or D), Gross Ton
3220 - Regulatory (Subpart C or D), Net Ton
10126 - Dead Weight, Metric Ton
13712 - Displacement, Metric Ton
6522 - Convention (Subpart B), Gross Ton
3220 - Convention (Subpart B), Net Ton
3220 - Regulatory (Subpart C or D), Net Ton
10126 - Dead Weight, Metric Ton
13712 - Displacement, Metric Ton
6522 - Convention (Subpart B), Gross Ton
3220 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 44
30 April 2019
NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6672788
23 April 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6668867
14 April 2019
PII Safety Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6658321
27 March 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6648915
22 March 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6647329
11 March 2019
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6634836
29 June 2018
MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6460109
29 June 2018
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6496820
8 March 2018
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6354652
10 May 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333320
9 May 2017
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6142802
17 March 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6106796
6 March 2017
Deficiency Check · Ballast Water Examination · ISPS II Exam · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6098303
20 July 2015
Administrative Inspection · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5186142
16 October 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5006253
13 March 2014
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4815279
7 January 2012
ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4218153
8 September 2011
Joint Vessel Security Verification (Massena only) · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4140033
15 July 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4082634
12 December 2010
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3909765
18 December 2009
MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex II Examination · Ballast Water Examination · COC-CHEM Annual · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3652606
29 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3549851
6 July 2009
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3525883
1 April 2009
Ballast Water Examination · Joint Vessel Security Verification (Massena only) · ISPS III Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3445513
17 November 2008
ISPS II Exam · Ballast Water Examination · MARPOL Annex II Examination · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3364541
25 March 2008
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3170892
17 February 2008
ISPS III Exam · Ballast Water Examination · COC-CHEM Annual · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3148886
9 October 2007
Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3075806
8 October 2007
Type not recorded
No type recorded · Maritime Safety & Security Team Cape Cod (91110) · Activity 3075599
27 September 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3071284
21 April 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2913611
3 January 2007
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2849521
2 January 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2849068
24 October 2006
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2806868
7 August 2006
Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2735176
7 August 2006
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2739720
6 November 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2542425
20 August 2005
Ballast Water Examination · COC-CHEM Annual · ISPS III Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2468800
20 May 2005
Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2361369
20 May 2005
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2361372
6 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2269867
15 July 2004
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2133637
15 July 2004
ISPS I Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2133647
12 May 2004
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2072599
Deficiency record · 48
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 April 2019
Resolved
07115 - Fire Safety - Fire-fighting system and applications shall be in good working order and ready for immediate use. Port side inner pneumatic fore dampner on stack inoperable. - 74 SOLAS 09 con. II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2019
Resolved
07105 - Fire Safety - Doors required to be self-closing shall not be fitted with hold back hooks. However, hold-back arrangement fitted with remote release devices of the fail-safe type may be utilized. Stairway entrance on poop deck self closing door did not close during activation of the fire alarm. - 74 SOLAS 09 con. II-2/9.4.2.2
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 April 2019
Resolved
07106 - Fire Safety - Manually operated call points shall be installed throughout the accomodation spaces, service spaces and control stations. On manually operated call point shall be located at each exit. 74 SOLAS 09 con. II-2/7.7
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 April 2019
Resolved
03103 - Water/Weatheright Conditions - Fixed, removable or hinged stanchions shall be fitted 1.5 m apart. Removable or hinged stanchions shall be capable of being locked in the upright position. Port-Aft stanchions by rescue boat are broken and wasted.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 22 April 2019
Resolved
Fire-fighter's outfits shall comply with the fire safety code. Personal equipment shall consist of protective clothing of material to protect the skin from heat radiating from the fire and from burns and scalding by steam. 3 out of 4 fire fighters helmets protective material found deteriorated.
74 SOLAS (04) II-2/10.1 - FSS 3.2.1.1.1 - 17 a/c
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 14 April 2019
Resolved
Before the ship leaves port and at all times during the voyage all life saving appliances shall be in working order and ready for immediate use. During test of the rescue boat davit, crew had to make modifications in order to operate the davit properly. Limit switch was inoperable. Crew did not utillize painter line. - 74 SOLAS (14) III/20.2 & 34 - LSA 6.1.2.7 - 17 a/c
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 14 April 2019
Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. The following electrical hazards were found in the cargo deck area: wasted connection on light fixture connected to cat walk railing over cargo tank #2 starboard. Wasted panel and connections to both port and starboard cargo pumps on tank #2. Wasted cable piping leading to tank radar on starboard slop tank, aft section of tank, also mid section of tank. Electrical sensor and cable on WBT 6 port has wasted connections. - 74 SOLAS (04) VII/10.1 - IBC 10.1.2.1 - 17 a/c
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 14 April 2019
Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the administration. Wastage found on cable boxes abnd piping in the cargo deck area, in the following areas: Piping connections to cable box in vicinity of 6 starboard WBT, cargo tank 4 port, upper and lower cable boxes on cargo tank 6 port, outboard of the P/V valve. Also, aft most port side cable box has piping and exposed cable running from it with frayed wiring. - 74 SOLAS (04) II-1/45.5.4 - 17 a/c
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2019
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those in compartments assigned principally to paint lockers unless the Administration is satisfied that such equipment is appropriate to the space concerned. Paint locker light fixture casing was found cracked. - 74 SOLAS (04) II-1/45.10.3 - 17 a/c
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 14 April 2019
Resolved
Electrical equipment, cables and wiring which do not conform to the standards may be installed in hazardous locations based on a risk assessment, to ensure that an equivalent level of safety is assured. Doors leading to the safety locker and deck store, directly from the cargo deck area, have wasted gasket material and do not create a seal. These doors are labeled "to be closed during cargo." - 74 SOLAS (04) VII/10.1 - IBC 10.1.4 - 17 a/c
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 14 April 2019
Resolved
The appropriate load lines on the sides of the ship corresponding to the season of the year of the zone in which the ship may be shall not be submerged at any time when the ship puts to sea, during the voyage or on arrival. Summer load line submerged by 2". - ILLC (88)/12 - 17 a/c
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 14 April 2019
Resolved
Means of communication shall be provided between the navigation bridge and steering gear compartment. Communications found inoperable. - 74 SOLAS (04) II-1/29.10 - 10 c
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 March 2019
Resolved
11129-Life Saving-All life-saving appliances shall be in working order and ready for immediate use. The davit for the rescue boat and davit-launched life raft deployment was found to be inoperable.-SOLAS 74 (14) III/20.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 March 2019
Resolved
07199-Fire Fighting Equipment-Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. Electrical equipment located on the cargo deck grounding straps are disconnected or missing.-SOLAS 74 (04) VII/10.1-IBC Code 10.1.2.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 March 2019
Resolved
02108-Structural Conditions-Independent cargo tanks shall be electrically bonded to the hull along with all gasketed cargo pipe joints and hose connections shall be electrically bonded. Bonding cables located on the cargo deck are either missing or deteriorated.-SOLAS 74 (04) VII/10.1-IBC Code 10.2
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 March 2019
Resolved
11113-Life Saving-Rescue boats shall be in a state of continuous readiness for launching in not more than 5 minutes. Crew was unable to launch rescue boat within the alloted time frame.-SOLAS 74 (14) III/14.1
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 13 March 2019
Resolved
07102-Fire Fighting Equipment-Where inerting or padding of cargo tanks is required, an adequate supply of inert gas for use in filling and discharging the cargo tanks shall be carried. Crew was unable to demonstrate
the operation of the installed nitrogen generator to produce the required inert gas.-SOLAS 74 (04) VII/10.1-IBC Code 9.1.3.1
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 13 March 2019
Resolved
09206-Working and Living Conditions-Satisfactory means in the form of guard rails and/or lifelines shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and all other parts used in the necessary work of the ship. Numerous guard rails and/or lifelines throughout the cargo deck are deteriorated.-ILLC 66 I/25.4
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 13 March 2019
Resolved
07102-Fire Safety-The inert gas system shall be tested in accordance with the Fire Safety Systems Code. Crew was unable demonstrate the operation of audible and visual alarms required for a nitrogen generator.-SOLAS 74(04)II-2/4.5.5.3.2 FSS Code 15.2.4.2
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 13 March 2019
Resolved
03108-Water/Weathertight Conditions-Air Pipes shall have a satisfactory means, permanently attached ,for closing the openings of the air pipes. Numerous air pipes closing devices were missing and/or inoperable.-ILLC 66 I/20
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 March 2019
Resolved
15109-Safety Management System-The company should identify equipment and technical systems that
the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. These measures should include the regular testing of stand-by arrangements and equipment or technical systems that are not in continuous use. No measures have been carried on board the vessel promoting the reliability and testing of equipment and/or systems not in continuous use.-SOLAS 74 (14) IX/5-ISM Code Part A 10.3
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 13 March 2019
Resolved
15108-Safety Management Systems-The inspections mentioned in the ISM Code 10.2 should be integrated into the ship's operational maintenance routine. Inspections are not being held at appropriate intervals, not all non-conformities are being reported, records of the activities are not being recorded, and appropriate corrective action is not being carried out.-SOLAS 74 (14) IX/5-ISM Code Part A 10.4
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 13 March 2019
Resolved
15102-Safety Management Systems-Objective evidence discovered in an expanded ISM examination revealed the follow major non-conformity; the vessel failed to
implement the requirements of the Safety Management System as
evident by deficiencies noted on this form. An external audit is required.-SOLAS 74 (14) IX/3&5-ISM Code Part A 9 & 10
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 13 March 2019
Resolved
06105-Cargo Operations including equipment-When the hydrocarbon gas concentration, in the double bottom hull spaces and double bottom spaces, reaches a pre-set level, a
audible alarm signal shall be automatically activated in the cargo control room to alert personnel to the potential hazard. Crew was unable to demonstrate the operation of the fixed gas detection alarm system.-SOLAS 74 (04) II-2/1.6.7
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 13 March 2019
Resolved
06105-Cargon Operations Including Equipment-The materials of construction and the dimensions of the gas sampling lines shall be such as to prevent restriction. The gas sampling lines on the cargo deck are deteriorated.-SOLAS 74 (04) II-2/4.5.7.2.3
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 13 March 2019
Resolved
14101-Pollution Prevention-A tank vessel that is carrying 250 or more barrels of oil or hazardous material as cargo must have a means of draining or removing the product from the discharge containment. The discharge containment drain piping for the starboard cargo manifold is deteriorated.-33 CFR 155.310 (a)(2)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 13 March 2019
Resolved
06106-Cargo Operations Including Equipment-The cargo handling equipment shall be maintained by the tank vessel's personnel in accordance with regulations in 46 CFR Subpart 35.35-Cargo Handling. The cargo pump and associated cargo piping pressure gauges are unreadable.-46 CFR 35.35-70
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 March 2019
Resolved
06199-Cargo Operations Including Equipment-Vapor piping systems and pressure-vacuum valves that are used for polymerizing cargoes must be inspected internally at least annually. Crew provided no evidence that this has been carried out.-46 CFR 39.2014(b)
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 13 March 2019
Resolved
12112-Dangerous Goods-The fire safety objectives of SOLAS 74 (04) are to prevent the occurrence of fire and explosion. Flammable products (methanol) in 55 gallon drums are being stored on the cargo block cat walk without any measures to mitigate a potential hazard.-SOLAS 74 (14) II-2/2.1.1
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 11 March 2019
Resolved
07102-Fire Safety-The inert gas system shall be designed and tested in accordance with the Fire Safety Systems Code. Crew was unable to
demonstrate operation of the installed double block and bleed arrangement to in order to prevent the return of vapor and liquids to the inert gas plant or to any gas-safe space.-SOLAS 74 (04) II-2/4.5.5.3.2-FSS Code 15.2.2.3.1.1-FSS Code 15.2.2.3.1.2
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2019
Resolved
02108-Structural Conditions-The vapor collection piping must be electrically bonded to the hull and be electrically continuous. Numerous bonding cables and/or straps are either missing or deteriorated throughout the cargo deck.-46 CFR 39.2001(d)
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 29 June 2018
Resolved
ANY DISCHARGE THROUGH THE OIL DISCHARGE MONITORING EQUIPMENT NEEDS TO BE PROCEEDING EN ROUTE AND MORE THAN 50 NAUTICAL MILES. VESSELS ODME WAS FOUND TO HAVE DISCHARGED WHILE IN PORT CREAATING A SHEEN.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 8 March 2018
Resolved
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR IT'S OPERATION AND CONTROL. THE PROPULSION CONTROL SYSTEM LOCATED IN THE ENGINE CONTROL ROOM WAS NON-OPERATIONAL. 74 SOLAS (2004) II-1/31.1
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 8 March 2018
Resolved
ONLY ONE TYPE OF FOAM CONCENTRATE SHALL BE SUPPLIED AND IT SHALL BE EFFECTIVE FOR THE MAXIMUM POSSIBLE NUMBER OF CARGOES INTENDED TO BE CARRIED. THE FOAM CARRIED ON BOARD IS NOT ALCOHOL-RESISTANT AND IS NOT A SATISFACTORY FORM OF FIREFIGHTING FOR CARGO THAT CAN BE CARRIED ACCORDING TO THE SHIP'S INTERNATIONAL CERTIFICATE OF FITNESS. 74SOLAS(2014) VII/10.1; IBC CODE 11.3.2
Deck/Cargo › Mooring/Anchoring › Brake
Issued 10 May 2017
Resolved
Vessel experienced a reduction in speed while transiting inbound to Houston due to the starboard anchor releasing and dragging. Prior to moving the vessel shall submit documentation from certificate issuing authority attesting to the root cause of the starboard anchor releasing, full functionality of both anchor windlass and associated anchor handing gear including chain stoppers, and affirmation
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 6 March 2017
Resolved
0611 Each survival craft shall be stowed fully equipped by this chapter and the code. The lifeboat had 27 out of 57 total water packages expired 09 months ago. 74 SOLAS (14) III/13.1.4 LSA CODE 4.4.8.9 ISM CODE PART A 10.1
Electrical › Electric Generation Source (service) › Panelboard
Issued 6 March 2017
Resolved
0899 Electrical Installations shall be such that the safety of passengers, crew, and ship from electrical hazards wil be ensured. Electrical panel main battery switch behind switchboard not properly installed to panel. 74 SOLAS (04) II-1/40.1.3
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 6 March 2017
Resolved
2510 Vessels policy is no phone use outside of accomodation spaces. At least 03 non-crew individuals were observed operating their mobile phones on main deck while in the presence of the crew. The vessel is currently in a loaded condition with a flammable cargo. 74 SOLAS (14) IX/5 ISM CODE PART A 7
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 6 March 2017
Resolved
0720 Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Two out of six foam monitors were clogged with rust and could not provide adequate coverage on deck. 74 SOLAS (04) II-2/14.2.12 ISM CODE PART A 10
Lifesaving › Rescue Boat › Propulsion Engine
Issued 6 March 2017
Resolved
0615 Rescue Boats shall be stowed in a state of continuous readiness for launching in not more than five minutes. Rescue boat was unable to achieve astern propulsion for at least 20min. 74 SOLAS (14) III/14.1 ISM CODE PART A 10
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 6 March 2017
Resolved
1899 Each vessel vapor connection flange face must have a permanant stud. All four vapor manifold connections have threaded studs at 12 o'clock position. 46CFR39.2001(j)
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 6 March 2017
Resolved
1099 Each tankship with a VCS must have a high pressure alarm that gives an audible alarm where cargo transfer is controlled. Audible alarm was found to be disabled during the exam. 46CFR39.2013(b)(1)
Operations/Management › Ballast Water Managment › Ballast Retention
Issued 1 April 2009
Resolved
Vessels AP tank did not meet the 30ppt requirement. the reading was 27ppt. Vessel is to retain ballast water while in U.S. waters.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 9 October 2007
Resolved
The winch pump in the ship's forecastle is leaking hydraulic fluid creating a fire hazard.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 20 August 2005
Resolved
VCS alarms are not set in accordance with vapor control manual (90 %). There is no audio for high level alarm. Vessel not to load cargo requiring VCS.
Documentation › Certificates/Documents › IOPP Certificate
Issued 20 August 2005
Resolved
IOPP states maximum throughput of OWS is 1.0 m3/h. OWS Manual States max throughput is 1.5 m3/h.
Fire Fighting › Fire Hoses
Issued 12 May 2004
Resolved
Foam applicators did not fit fire hoses. LEGACY COMPONENT DESC: Foam Applicators
Documentation › Manuals/Policy Documentation
Issued 12 May 2004
Resolved
Vapor control approval letter not on board. LEGACY COMPONENT DESC: Vapor Control Letter