MAURY USCG vessel records
← All vessels

ISLAND PEARL

ISLAND PEARL is a 1990 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in May 2026, along with 28 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 1 May 2026.

Built
1990
Last inspected
1 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG 2519
681958
Flag
UNITED STATES
Maury page id
psix-681958

Documentation record

Registered dimensions (L × B × D)50.0 ft × 14.5 ft × 4.5 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC · ANAHEIM, CA, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portMARATHON, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

1 May 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8361433
14 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8350949
16 October 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8253468
1 May 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8127011
20 May 2024 Internal Structural Exam · Hull Examination · Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7915910
1 March 2023 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7631069
15 February 2022 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7375489
15 November 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7331962
8 February 2021 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7127009
11 March 2020 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6917872
10 January 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6884546
19 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6617145
16 April 2018 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6376142
20 December 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6327205
3 February 2017 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6082466
28 April 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5858435
19 January 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5799561

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2026 Resolved
Both high water alarms are not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2026 Resolved
Repair broken grounding wire in AFT compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2026 Resolved
Update drills and EPIRB logs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2025 Resolved
Remove wing nuts from batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 17 October 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 October 2025 Resolved
Replace housing on stern light. Housing to light is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 17 October 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 October 2025 Resolved
Replace high water alarm in Engine room. Only has audible alarm no visual light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 17 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 May 2025 Resolved
(a) A vessel on an oceans, coastwise, limited coastwise or Great Lakes route must carry (1)06 red hand red flare distress signals approved in accordance with 160.021 in subchapter Q of this chapter, (2)06 hand orange smoke distress signals approved in accordance with 160.037 in subchapter Q of this chapter. (c)(1) Rocket parachute flare approved by 160.036 maybe be substituted for either. Vessel's distress signals are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: 12 new onboard
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2025 Resolved
Every vessel subject to Part III of Title II of the Communications Act must have a detailed inspection of the radio installed by an FCC-licensed technician in accordance with 80.59, once every five years. Vessel missing its FCC certificate. 47 CFR 80.903
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: New cert issued
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 May 2025 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHZ EPIRB be registered with NOAA before installation and that information be kept up to date. Registration has expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: Verified EPIRB is registered and info is current
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 May 2025 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release has expired. Vessel restricted to no more than 1 mile from shore.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: New release installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2025 Resolved
Spanner wrenches must be provided where a 1.5" fire hose is required. Vessel is missing 01 spanner wrenches. Vessel missing its spanner wrench.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: Spanner wrench onboard
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 1 May 2025 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Recommended emergency instructions, as appropriate, can be found in 46 CFR 184.510. Placard is missing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: New placard posted
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 1 May 2025 Resolved
The master of the vessel shall ensure that the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB test were not being logged for the 2nd consecutive inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: educated and new log created.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 June 2024 Resolved
TO maintain a valid Certificate of Inspection, you must complete your annual inspection with in the periods specified in 176.500(b)(1) and your COI must be endorsed. Vessel's COI was not endorsed due to the large number of deficiencies found. Vessel is restricted from carrying passengers until the following work list items are rectified. 1. Provide evidence crew trained on EAP 2. Produce current DAPI roster and consortium contract, CLEARED 3. Produce charts, publications and coast pilot 4. No drill or radio logs, EDUCATED/CLEARED 5. FCC station license CLEARED 6. FCC safety radio telephony cert CLEARED 7. Post COI/stability letter under glass 8. Life ring grab lines wasted and ring not stenciled. 9. Machinery guard missing on main engine. 10 Portable bilge pump missing. 11 No high water alarm in shaft alley or lazarette 12 Label 02 fuel shutoffs. 13 Label PFD locations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2024
Resolution: All worklist items have been rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 8 February 2021 Resolved
A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant [name withheld] tiller to control auxiliary steering was not available. Taking control through auxiliary steering was not possible with its absence. 46 CFR 182.620 (b)
Action required: 705 - Other - as specified
Due 15 February 2021
Resolved 3 March 2021
Resolution: MI verified proper fit of new tiller.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 February 2021 Resolved
Each fire hose on a vessel not more than 65 feet in length carrying not more than 49 passengers must be lined commercial fire hose that conforms to UL 19 or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance. During operational test, MI observed hose to be leaking. Hose maintained appropriate pressure despite leak. 46 CFR 181.320 (c)(1)
Action required: 705 - Other - as specified
Due 15 February 2021
Resolved 12 March 2021
Resolution: Verified new fire hose to be 1.5” in diameter 50’ in length. Fittings were made of brass.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2021 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in sub-chapter Q. MI observed ring life buoy on starboard quarter to have deteriorated retro-reflective tape and markings. 46 CFR 180.70 (b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 12 February 2021
Resolution: Owner removed ring life buoy since regulation was met with additional ring life buoy in proper condition.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 February 2021 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. MI observed bracket connecting hydraulic ram rod for steering to be corroded and wasted. Bracket was able to be broken using only hands. 46 CFR 182.610 (a)(1)
Action required: 705 - Other - as specified
Due 15 February 2021
Resolved 12 February 2021
Resolution: Owner replaced in-kind.
Communications › Radio Communications › VHF Radiotelephone
Issued 16 April 2018 Resolved
Vessel's radio must have lat and long displayed for DSC. Vessel's radio only displayed the MMSI number. Update radio to display lat and long.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2018
Resolved 24 April 2018
Resolution: VHF radio now in compliance.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 8 January 2018 Resolved
ME sea strainer clogged with sediment and grasss. Clean prior to operation. 46 CFR 182.420 (2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2018
Engineering › Sea-water System (primary cooling) › Valve
Issued 8 January 2018 Resolved
ME raw water ball vavle difficult to turn. Replace or repair. 46 CFR 182.422 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2018
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2018 Resolved
port side hull near bow has an approx 2 foot gouge affecting the gel coat and some of the FRP. Make appropriate repairs. 46 CFR 176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2018
Lifesaving › Lifebuoys › Stowage
Issued 27 February 2017 Resolved
Life ring stowed incorrectly, correct to the satisfaction of the Marine Inspector. 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: Life ring stowage corrected to the satisfaction of the Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 February 2017 Resolved
Navigation lights extinguished. Provide new bulb for navigation lights. 46CFR183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: New bulbs provided for navigation lights to the satisfaction of the Marine Inspector.
Communications › Radio Communications › EPIRB
Issued 28 April 2016 Resolved
Replace hydrostatic release unit as per requirements. Vsl limited to no further than line of demarcation.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 13 May 2016
Resolution: Hydrostatic release unit replaced as required. No limit on route as listed on COI.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 28 April 2016 Resolved
Replace watertight seal of anchor room hatch.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 13 May 2016
Resolution: Watertight seal replaced of anchor room hatch.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 April 2016 Resolved
Provide ammonia inhalants as required.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 13 May 2016
Resolution: Ammonia inhalants present.
Electrical › Lighting (service) › Outlet Box
Issued 28 April 2016 Resolved
Provide electrical outlet covers as required.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 13 May 2016
Resolution: Electrical outlet covers present on all outlets boxes.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.