Inspection history · 13
4 May 2026
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8352537
28 July 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8196554
23 May 2024
Deficiency Check · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7903411
17 August 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7770643
28 July 2022
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7509952
9 December 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7363889
29 April 2019
Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6672353
27 July 2017
DAPI Audit · Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6223357
24 September 2014
Administrative Inspection · DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4991100
10 April 2014
Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4838018
8 June 2011
Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4039277
12 April 2011
Deficiency Check · Industry Initiated Exam · Administration · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3987095
23 January 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 313785
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 July 2025
Resolved
A towing vessel must carry a combination of day and night visual distress signals. Flares carried onboard were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2025
Resolution: Flares have been replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 July 2025
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Both port an STBD shafts have excessive leaking at shaft packing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2025
Resolution: Shaft packing has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2024
Resolved
The #2 port fuel piping had red hand at the deck plate along with about 9 inches down the fuel pipe into the bow void space – also examined the fuel containment loading station and witness excess fuel in the containment area. Fuel Pipe needs to be replaced/fixed prior to operation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 June 2024
Resolved 7 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024
Resolved
Remove extension cord for fan on the lower level engine room and install an outlet close to fan location.
Action required: 705 - Other - as specified
Due 7 August 2024
Resolved 18 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024
Resolved
Identify loose wire near rudder angle indicator by port rudder linkage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2024
Resolved 12 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024
Resolved
Junction box on top of pilot house with dead end loose wires. Secure deadends and wiring or remove.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 August 2023
Resolved
Search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. STBD light not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2023
Resolution: STBD light is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 August 2023
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. VSL missing 1 of 3 combination visual distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2023
Resolution: ADDED FLARE TO VESSEL (NOW HAS 3 TOTAL DAY/NIGHT FLARES)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 August 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Vessel had 02 battery chargers and 01 light ran off power strip via extension cords.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2023
Resolution: Removed power strip and extension cords
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 17 August 2023
Resolved
All fire extinguishers must be inspected or tested at least once every 12 months. Vessel missing extinguisher certification.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2023
Resolution: REVIEVED FROM CINTAS AND PLACED IN VESSEL FILES
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 August 2023
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2023
Resolution: REPLACED LIGHTS & WHISTLES ON TYPE-1's
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2023
Resolved
Each lifebuoy on a towing vessel must be approved under approval series 160.050 or 160.150. Lifebouy missing reflective markings and damaged lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2023
Resolution: REPLACED BOTH LIFEBOUY'S
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 August 2023
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Control panel not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2023
Resolution: REPLACED WIRE ON FIRE PANEL TO BATTERIES
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 August 2023
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces. No detectors in berthing space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2023
Resolution: INSTALLED NEW SMOKES DETECTORS ON 2ND DECK - CREW BERTHING
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 August 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port/STBD fire main vlv cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2023
Resolution: REPLACED BALL VALVES ON FIRE STATIONS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 August 2023
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with one or more spring-loaded relief valves. Relief vlv only installed in one PV with the ability to isolate it from other PV.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2023
Resolution: INSTALLED VALVE ON UPPER TANK
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2021
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. The cloth covers being used are not a suitable means of stopping airflow.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 25 January 2022
Resolution: A device has been provided for securing ventilation serving machinery spaces and for closing.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 9 December 2021
Resolved
In a space where the general alarm may not be heard a sign that reads: ‘‘Attention General Alarm — When Alarm Sounds or Flashes Go to Your Station." There is no sign by the alarm in the lower engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 13 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 December 2021
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent
protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. The clips used to secure the handlines were small and did not appear to provide adequate protection. Replace clips with more robust clips.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 13 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021
Resolved
The fuel shut off valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The current arrangement has the shut off next to the machinery. Owner shall make repairs at next dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2024
Resolved 23 May 2024
Resolution: See special note.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 July 2017
Resolved
Needs to provide the statistically based method used also provide a list of all required personnel in testing pool.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 1 November 2017
Resolution: To the satisfaction of the attending Coast Guard Marine Inspector
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 September 2014
Resolved
46 CFR 16.401 (b) requires that the Marine Employer Document the 60 mins of EAP training given to supervisors. The supervisors had recieved the training but documentation could be proved to the inspectors.
Action required: 705 - Other - as specified
Due 24 October 2014
Resolved 9 October 2014
Resolution: Training for supervisors completed and documented.