Records from 2016 to 2026. Most recent: inspection, 14 May 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.5 ft × 4.7 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRIQUES YACHTS INC · BAYVILLE, NJ, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portINDIAN RIVER, DE
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 21 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
14 May 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8376124
7 May 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8326958
13 May 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8137296
14 May 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7912864
1 May 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7905374
9 December 2023
Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7840516
21 April 2023
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7674682
8 March 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7647556
22 July 2022
Type not recorded
No type recorded · Station Ocean City · USCG East District (CGD-E) · Activity 7514945
20 May 2022
Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7457332
11 April 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7428571
16 June 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7270966
30 April 2020
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6945663
9 April 2020
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6935159
22 April 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6667406
19 November 2018
Type not recorded
No type recorded · USCGC LAWRENCE O. LAWSON (WPC 1120) · USCG East District (CGD-E) · Activity 6583453
25 April 2018
COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6393534
13 April 2018
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6391006
24 April 2017
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6131161
12 April 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5856634
8 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5830973
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2023
Resolved
46 CFR 176.808(C)
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Both life ring and life float water light batteries were expired. Replace with appropriate battery prior to operating at night.
Action required: 705 - Other - as specified
Resolved 6 May 2023
Resolution: O/O provided evidence of replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 21 April 2023
Resolved
46 CFR 180.130(a)(1)
Each survival craft must be stowed so when the vessel sinks the survival craft floats free. Life float painter is attached to weak link by large carabiner that once weak link is broken, the carabiner would not pass under the painter line housing. Remove carabiner and attach weak link directly to painter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: O/O installed weak link correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2023
Resolved
46 CFR 180.200(A)(2)
Each survival craft required on vessel by this part must meet the following: For a life float-Approved under approval series 160.027. Life float grab lines were deteriorated and need to be repaired. Remove gripes holding grab lines and repair IAW manufacturer suggestion.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: Grab lines have been repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2023
Resolved
46 CFR 181.420(a)(3)
A pre-engineered fixed gas extinguishing system must: automatically shut down all engines that draw intake air from within the protected space. Vessel generator did not shut down when the fireboy system was tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: Generator has been hooked up to fire suppression system.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 April 2023
Resolved
46 CFR 182.455(b)(4)
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Manual remote fuel shutoffs could not close the valves when testing. Repair pulls and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: Emergency shutoffs have been repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 April 2023
Resolved
46 CFR 184.502
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel needs to program MMSI and position (Lat/Long) into radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: MMSI and position have been programmed into radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2023
Resolved
46 CFR 183.200(c)
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Remove dead end wiring from port space forward of lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2023
Resolution: Dead end wiring has been removed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 April 2019
Resolved
Shut off valves, installed so as to close against the fuel flow, must be fitted in teh fuel supply lines.., and manually operable from outside the compartment. Sheathing for the port engine fuel shut off cable is corroded and broken. Renew fuel shut off cable. 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 16 May 2019
Resolution: Verified new cable installed and operable from outside the compartment.
Documentation › Certificates/Documents › FCC SSL
Issued 24 April 2017
Resolved
Provide valid FCC station license.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Copy of station license provided
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 April 2017
Resolved
Provide valid FCC Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Valid FCC Safety Certificate provided.
Lifesaving › Hand Flares › Quantity
Issued 24 April 2017
Resolved
Provide additional distress flares to meet the required total of 12.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Four additional red hand flares provided.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 24 April 2017
Resolved
Renew short sections of flexible supply and return fuel hose on generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: New flexible fuel hose installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2017
Resolved
Provide new items for expired items in first aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Expired items were renewed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 24 April 2017
Resolved
Apply retroreflective tape to lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: New tape applied on the each side of the lifefloat.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016
Resolved
Configure VHF-FM radio to comply with FCC regulations. Connect VHF-FM radio to GPS.
Due 12 May 2016
Resolved 22 April 2016
Resolution: VHF_FM radio is connected to the GPS device.