RESTLESS LADY II is a 2004 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2008, most recently in May 2026, along with 21 deficiencies.

Records from 2008 to 2026. Most recent: inspection, 14 May 2026.

Built
2004
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ8667
683956
Flag
UNITED STATES
368018630
Maury page id
psix-683956

Inspections, by type

…with no type recorded2
Years with a record 14 calendar years (2008–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.5 ft × 4.7 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRIQUES YACHTS INC · BAYVILLE, NJ, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portINDIAN RIVER, DE
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 7 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

EX296MMSI 368018630 · active · exemption · granted 12 January 2023, expires 12 January 2027
WDJ8667MMSI 368018630 · active · compulsorily equipped · granted 9 January 2018, expires 9 January 2028
WDD2362MMSI 367114360 · expired · compulsorily equipped · granted 23 February 2016, cancelled 27 June 2026 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

14 May 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8376124
7 May 2026 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8326958
13 May 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8137296
14 May 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7912864
1 May 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7905374
9 December 2023 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7840516
21 April 2023 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7674682
8 March 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7647556
22 July 2022 Type not recorded
No type recorded · Station Ocean City · USCG East District (CGD-E) · Activity 7514945
20 May 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7457332
11 April 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7428571
16 June 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7270966
30 April 2020 Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6945663
9 April 2020 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6935159
22 April 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6667406
19 November 2018 Type not recorded
No type recorded · USCGC LAWRENCE O. LAWSON (WPC 1120) · USCG East District (CGD-E) · Activity 6583453
25 April 2018 COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6393534
13 April 2018 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6391006
24 April 2017 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6131161
12 April 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5856634
8 March 2016 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5830973
26 March 2014 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4822540
29 March 2010 Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3702488
18 June 2008 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3239634
24 April 2008 COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3191493
19 March 2008 Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3167398
28 February 2008 Inclining Experiment
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2976250

Deficiency record · 21

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2023 Resolved
46 CFR 176.808(C) Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Both life ring and life float water light batteries were expired. Replace with appropriate battery prior to operating at night.
Action required: 705 - Other - as specified
Resolved 6 May 2023
Resolution: O/O provided evidence of replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 21 April 2023 Resolved
46 CFR 180.130(a)(1) Each survival craft must be stowed so when the vessel sinks the survival craft floats free. Life float painter is attached to weak link by large carabiner that once weak link is broken, the carabiner would not pass under the painter line housing. Remove carabiner and attach weak link directly to painter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: O/O installed weak link correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 April 2023 Resolved
46 CFR 180.200(A)(2) Each survival craft required on vessel by this part must meet the following: For a life float-Approved under approval series 160.027. Life float grab lines were deteriorated and need to be repaired. Remove gripes holding grab lines and repair IAW manufacturer suggestion.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: Grab lines have been repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2023 Resolved
46 CFR 181.420(a)(3) A pre-engineered fixed gas extinguishing system must: automatically shut down all engines that draw intake air from within the protected space. Vessel generator did not shut down when the fireboy system was tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: Generator has been hooked up to fire suppression system.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 April 2023 Resolved
46 CFR 182.455(b)(4) The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Manual remote fuel shutoffs could not close the valves when testing. Repair pulls and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: Emergency shutoffs have been repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 April 2023 Resolved
46 CFR 184.502 A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel needs to program MMSI and position (Lat/Long) into radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: MMSI and position have been programmed into radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2023 Resolved
46 CFR 183.200(c) Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Remove dead end wiring from port space forward of lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2023
Resolution: Dead end wiring has been removed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 April 2019 Resolved
Shut off valves, installed so as to close against the fuel flow, must be fitted in teh fuel supply lines.., and manually operable from outside the compartment. Sheathing for the port engine fuel shut off cable is corroded and broken. Renew fuel shut off cable. 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 16 May 2019
Resolution: Verified new cable installed and operable from outside the compartment.
Documentation › Certificates/Documents › FCC SSL
Issued 24 April 2017 Resolved
Provide valid FCC station license.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Copy of station license provided
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 April 2017 Resolved
Provide valid FCC Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Valid FCC Safety Certificate provided.
Lifesaving › Hand Flares › Quantity
Issued 24 April 2017 Resolved
Provide additional distress flares to meet the required total of 12.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Four additional red hand flares provided.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 24 April 2017 Resolved
Renew short sections of flexible supply and return fuel hose on generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: New flexible fuel hose installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2017 Resolved
Provide new items for expired items in first aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: Expired items were renewed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 24 April 2017 Resolved
Apply retroreflective tape to lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 28 April 2017
Resolution: New tape applied on the each side of the lifefloat.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016 Resolved
Configure VHF-FM radio to comply with FCC regulations. Connect VHF-FM radio to GPS.
Due 12 May 2016
Resolved 22 April 2016
Resolution: VHF_FM radio is connected to the GPS device.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 April 2008 Resolved
fixed fire fighting system not yet serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Resolution: recieved report via fax.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 April 2008 Resolved
portable fire extinguisher have not yet been serviced properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Resolution: recieved report of replacement of affected bottle, via fax.
Documentation › Logs/Records › Logbook (official)
Issued 24 April 2008 Resolved
no bridge log, LS/FF equipment maintenance log, or drill log.
Action required: 705 - Other - as specified
Due 29 May 2008
Resolved 5 May 2008
Resolution: log book established.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 24 April 2008 Resolved
the vessel had yet produced vessel emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Resolution: emergency insrtuctions now posted.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 April 2008 Resolved
no current copy of CG light list was available.
Action required: 705 - Other - as specified
Due 29 May 2008
Resolved 5 May 2008
Resolution: recieved reciept of CG light list purchase, via fax.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 April 2008 Resolved
no marking was installed upon fwd means of escape.
Action required: 705 - Other - as specified
Due 29 May 2008
Resolved 5 May 2008
Resolution: means of escape properly marked.

Ownership record