MAURY USCG vessel records Sign in
← All vessels

TJ HARVEST

TJ HARVEST is a 2004 freight ship. The Coast Guard has recorded 20 inspections since 2004, most recently in May 2024, along with 9 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 2004 to 2024. Most recent: inspection, 14 May 2024.

Built
2004
Last inspected
14 May 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9267091 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
684384
Flag
HONG KONG
—
Maury page id
psix-684384

Inspections, by type

…with no type recorded8
Years with a record 8 calendar years (2004–2024)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it32038 - Dead Weight, Ton
39449 - Displacement, Ton
19730 - Convention (Subpart B), Gross Ton
11006 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

14 May 2024 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7912049
11 August 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7531453
8 August 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7521917
21 November 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6045055
20 November 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6041247
22 December 2015 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 5807760
16 December 2015 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5782580
7 March 2009 MARPOL Annex I Examination · ISPS I Exam · Ballast Water Examination · NPV Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3424935
8 February 2009 PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3414048
22 September 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3063329
24 July 2007 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3006011
10 September 2005 ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2481981
5 September 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2493907
23 June 2005 Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2400551
22 October 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2226574
5 August 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2157477
27 July 2004 ISPS II Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2146794
26 May 2004 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2072230
23 May 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2075522
19 May 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2072336

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations toensure that the ship will remain fit to proceed to sea. PSCO observed leaking sea water from ballast water pump. 74SOLAS(20) I Reg.11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2022
Resolution: Received Class Report attesting to the proper repairs to seal for ballast pump.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 11 August 2022 Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction. PSCO observed leak of hydraulic oil on No.1 steering gear at apprx. 10 drips per minute. 74SOLAS(04) II-1 Reg.29.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2022
Resolution: Received Class Report attesting to proper repairs of the NO.1 steering gear.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2022 Resolved
Paint lockers shall be protected by a water spraying or sprinkler system. PSCO observed paint cans in paint locker stacked above the sprinkler system. 74SOLAS(04)II-2 Reg.10.6.3.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2022
Resolved 9 August 2022
Resolution: Paint cans were placed in a satisfactory manner.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 August 2022 No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations toensure that the ship will remain fit to proceed to sea. PSCO observed leaking sea water from ballast water pump. 74SOLAS(20) I Reg.11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 August 2022 No resolution recorded
All steering gear components and the rudder stock shall be of sound and reliable construction. PSCO observed leak of hydraulic oil on No.1 steering gear at apprx. 10 drips per minute. 74SOLAS(04) II-1 Reg.29.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 8 February 2009 Resolved
Most of the available fruits and vegetables on board are rotten or affected by mold. These provisions are not fit for the crew to eat. This creates an unsafe situation due to possible food borne illness. ILO 147
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2009
Resolution: Received delivery receipt for fresh fruits and vegetables.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 February 2009 Resolved
The portable 4 gas meter is past due for calibration by one month, not allowing accurate measurements in the cargo holds for oxygen and toxicity and flammability. SOLAS 01 VI.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2009
Resolution: Received shore calibration report for portable meter.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 24 July 2007 Resolved
The vessel's Oil Transfer procedures are incomplete, and therefore they are not in accordance with 33 CFR 155.750. The vessel is prohibited from conducting Bunkering Operations in U.S. waters until Oil Transfer Procedures have been submitted,accepted, and approved by the attending Coast Guard Marine Inspector.
Action required: 703 - Prior to bunkering operations
Resolved 25 July 2007
Resolution: Received proper documentation from ship satisfying requirement
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 24 July 2007 Resolved
The vessel does not have its prepared Non-Tank Vessel Response Plan on board in accordance with the United States Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation Act of 2004. The vessel must maintain a copy of its Non-Tank Vessel Response Plan on board at all times while operating in navigable waters of the United States.
Action required: 705 - Other - as specified
Resolved 25 July 2007
Resolution: Received proper documentation from ship satisfying requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.