Records from 2016 to 2024. Most recent: inspection, 14 May 2024.
Inspection history · 5
14 May 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7912049
11 August 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7531453
8 August 2022
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7521917
21 November 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6045055
20 November 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6041247
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations toensure that the ship will remain fit to proceed to sea. PSCO observed leaking sea water from ballast water pump. 74SOLAS(20) I Reg.11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2022
Resolution: Received Class Report attesting to the proper repairs to seal for ballast pump.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 11 August 2022
Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction. PSCO observed leak of hydraulic oil on No.1 steering gear at apprx. 10 drips per minute. 74SOLAS(04) II-1 Reg.29.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 August 2022
Resolution: Received Class Report attesting to proper repairs of the NO.1 steering gear.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2022
Resolved
Paint lockers shall be protected by a water spraying or sprinkler system. PSCO observed paint cans in paint locker stacked above the sprinkler system.
74SOLAS(04)II-2 Reg.10.6.3.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2022
Resolved 9 August 2022
Resolution: Paint cans were placed in a satisfactory manner.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 August 2022
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations toensure that the ship will remain fit to proceed to sea. PSCO observed leaking sea water from ballast water pump. 74SOLAS(20) I Reg.11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 August 2022
No resolution recorded
All steering gear components and the rudder stock shall be of sound and reliable construction. PSCO observed leak of hydraulic oil on No.1 steering gear at apprx. 10 drips per minute. 74SOLAS(04) II-1 Reg.29.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign