MAURY USCG vessel records
← All vessels

ENERGY CENTURY

ENERGY CENTURY is a 2003 tank ship. The Coast Guard has recorded 3 inspections since 2016, most recently in July 2017, along with 7 deficiencies.

Records from 2016 to 2017. Most recent: inspection, 8 July 2017.

Built
2003
Last inspected
8 July 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 July 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9259329
684670
Flag
ISLE OF MAN
Maury page id
psix-684670

Documentation record

Tonnage as PSIX records it19597 - Convention (Subpart B), Net Ton
83976 - Displacement, Metric Ton
70201 - Dead Weight, Metric Ton
41397 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

3 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

8 July 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6195896
10 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6068932
21 July 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5942313

Deficiency record · 7

Deck/Cargo › Inert Gas System › IGS Blower
Issued 11 July 2017 Resolved
1899; 74 SOLAS (2004 CONS.) II-2/4.5.5.3.2 FSS CODE 15.2.3.1.6.1 SPECIAL CONSIDERATION SHALL BE GIVEN TO THE DESIGN AND LOCATION OF SCRUBBER AND BLOWERS WITH RELEVANT PIPING AND FITTINGS IN ORDER TO PREVENT FLUE GAS LEAKAGES INTO ENCLOSE SPACES. NUMBER "A" BLOWER SHAFT SEAL IS WORN ALLOWING INERT GAS INTO THE SPACE.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2017
Resolved 12 July 2017
Resolution: SEE ATTACHED CLASS REPORT.
Deck/Cargo › Inert Gas System › Venting System
Issued 21 July 2016 Resolved
1899- Other (tankers)- Suitable means shall be provided for the zero and span calibration of both fixed gas concentration measurement instruments. PSCO observed crew was unable to conduct zero span calibration of IG system. Crew appeared unfamiliar with proper procedures and PSCO observed sensor screen displayed error stating, "Calibration Impossible." 74 SOLAS 04 II-2/4.5.3.2; FSS Ch. 15/2.4.2.5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 21 July 2016 Resolved
1899- Portable instruments for measuring oxygen and flamable vapour concentration shall be provided. PSCO observed that the battery was low and needed to be replaced on one O2 instrument. Additionally, one flammable vapour instrument was connected with incorrect quick connect interconnect. The pump on one flammable vapour instrument was not functioning. 74 SOLAS(04) II-2/4.5.3.2;FSS Ch. 15/2.4.2.4
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 July 2016 Resolved
1730- Oily Water Separating Equipment- Oil filtering equipment shall be such that an oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. PSCO observed that the OWS is not properly functioning. Crew stated malfunction in most likely with the internal power supply unit for the oil content meter. MARPOL ANNEX I CH. 3/14.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 21 July 2016 Resolved
1899- Other (tankers)- The vapor connection must be painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter and labeled with the word "VAPOR" painted in black letters at least 50.8mm (2in) high. PSCO observed the port aft vapor manifold was painted in a sequence of gray/yellow/red and the word "VAPOUR" was painted yellow. 46 CFR 39.2001(h)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 21 July 2016 Resolved
1499- Other (Prop. & Aux. Machinery)-Where automatic starting is not required, manual starting is permissible, such as manually charged hydraulic accumulators, where they can be demonstrated as being effective. PSCO observed manual hydraulic start did not function on first 6 attempts. 74 SOLAS (04) II-1/44.4.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: After running the generator using battery start several times they hydraulic starat worked on the 7th attempt. PSCO returned 2 hours later and satisfactorily tested hydraulic starting system.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 21 July 2016 Resolved
2120- Garbage- Every ship shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for minimizing, collecting, storing, and disposing of garbage including the use of equipment on board. PSCO observed that plan did not include any ship specific information. MARPOL ANNEX V/10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: C/O added missing information to the satisfaction of PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.