Deck/Cargo › Inert Gas System › IGS Blower
Issued 11 July 2017
Resolved
1899; 74 SOLAS (2004 CONS.) II-2/4.5.5.3.2 FSS CODE 15.2.3.1.6.1 SPECIAL CONSIDERATION SHALL BE GIVEN TO THE DESIGN AND LOCATION OF SCRUBBER AND BLOWERS WITH RELEVANT PIPING AND FITTINGS IN ORDER TO PREVENT FLUE GAS LEAKAGES INTO ENCLOSE SPACES. NUMBER "A" BLOWER SHAFT SEAL IS WORN ALLOWING INERT GAS INTO THE SPACE.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2017
Resolved 12 July 2017
Resolution: SEE ATTACHED CLASS REPORT.
Deck/Cargo › Inert Gas System › Venting System
Issued 21 July 2016
Resolved
1899- Other (tankers)- Suitable means shall be provided for the zero and span calibration of both fixed gas concentration measurement instruments. PSCO observed crew was unable to conduct zero span calibration of IG system. Crew appeared unfamiliar with proper procedures and PSCO observed sensor screen displayed error stating, "Calibration Impossible." 74 SOLAS 04 II-2/4.5.3.2; FSS Ch. 15/2.4.2.5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 21 July 2016
Resolved
1899- Portable instruments for measuring oxygen and flamable vapour concentration shall be provided. PSCO observed that the battery was low and needed to be replaced on one O2 instrument. Additionally, one flammable vapour instrument was connected with incorrect quick connect interconnect. The pump on one flammable vapour instrument was not functioning. 74 SOLAS(04) II-2/4.5.3.2;FSS Ch. 15/2.4.2.4
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 July 2016
Resolved
1730- Oily Water Separating Equipment- Oil filtering equipment shall be such that an oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. PSCO observed that the OWS is not properly functioning. Crew stated malfunction in most likely with the internal power supply unit for the oil content meter. MARPOL ANNEX I CH. 3/14.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 21 July 2016
Resolved
1899- Other (tankers)- The vapor connection must be painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter and labeled with the word "VAPOR" painted in black letters at least 50.8mm (2in) high. PSCO observed the port aft vapor manifold was painted in a sequence of gray/yellow/red and the word "VAPOUR" was painted yellow. 46 CFR 39.2001(h)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 21 July 2016
Resolved
1499- Other (Prop. & Aux. Machinery)-Where automatic starting is not required, manual starting is permissible, such as manually charged hydraulic accumulators, where they can be demonstrated as being effective. PSCO observed manual hydraulic start did not function on first 6 attempts. 74 SOLAS (04) II-1/44.4.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: After running the generator using battery start several times they hydraulic starat worked on the 7th attempt. PSCO returned 2 hours later and satisfactorily tested hydraulic starting system.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 21 July 2016
Resolved
2120- Garbage- Every ship shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for minimizing, collecting, storing, and disposing of garbage including the use of equipment on board. PSCO observed that plan did not include any ship specific information. MARPOL ANNEX V/10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: C/O added missing information to the satisfaction of PSCO.