ENERGY CENTURY

ENERGY CENTURY is a 2003 tank ship. The Coast Guard has recorded 13 inspections since 2004, most recently in July 2017, along with 8 deficiencies and 3 operational controls.

Records from 2004 to 2017. Most recent: inspection, 8 July 2017.

Built
2003
Last inspected
8 July 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9259329 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
684670
Flag
ISLE OF MAN
—
Maury page id
psix-684670

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2004–2017)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it19597 - Convention (Subpart B), Net Ton
83976 - Displacement, Metric Ton
70201 - Dead Weight, Metric Ton
41397 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

8 July 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6195896
10 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6068932
21 July 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5942313
27 June 2014 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4891320
12 July 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4377123
11 July 2012 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4375284
20 January 2012 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4228277
29 August 2011 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4129721
29 September 2007 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3065143
24 January 2006 Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2572093
4 February 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2287023
21 May 2004 MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2073425
20 May 2004 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2073046

Deficiency record · 8

Deck/Cargo › Inert Gas System › IGS Blower
Issued 11 July 2017 Resolved
1899; 74 SOLAS (2004 CONS.) II-2/4.5.5.3.2 FSS CODE 15.2.3.1.6.1 SPECIAL CONSIDERATION SHALL BE GIVEN TO THE DESIGN AND LOCATION OF SCRUBBER AND BLOWERS WITH RELEVANT PIPING AND FITTINGS IN ORDER TO PREVENT FLUE GAS LEAKAGES INTO ENCLOSE SPACES. NUMBER "A" BLOWER SHAFT SEAL IS WORN ALLOWING INERT GAS INTO THE SPACE.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2017
Resolved 12 July 2017
Resolution: SEE ATTACHED CLASS REPORT.
Deck/Cargo › Inert Gas System › Venting System
Issued 21 July 2016 Resolved
1899- Other (tankers)- Suitable means shall be provided for the zero and span calibration of both fixed gas concentration measurement instruments. PSCO observed crew was unable to conduct zero span calibration of IG system. Crew appeared unfamiliar with proper procedures and PSCO observed sensor screen displayed error stating, "Calibration Impossible." 74 SOLAS 04 II-2/4.5.3.2; FSS Ch. 15/2.4.2.5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 21 July 2016 Resolved
1899- Portable instruments for measuring oxygen and flamable vapour concentration shall be provided. PSCO observed that the battery was low and needed to be replaced on one O2 instrument. Additionally, one flammable vapour instrument was connected with incorrect quick connect interconnect. The pump on one flammable vapour instrument was not functioning. 74 SOLAS(04) II-2/4.5.3.2;FSS Ch. 15/2.4.2.4
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 July 2016 Resolved
1730- Oily Water Separating Equipment- Oil filtering equipment shall be such that an oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. PSCO observed that the OWS is not properly functioning. Crew stated malfunction in most likely with the internal power supply unit for the oil content meter. MARPOL ANNEX I CH. 3/14.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 21 July 2016 Resolved
1899- Other (tankers)- The vapor connection must be painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter and labeled with the word "VAPOR" painted in black letters at least 50.8mm (2in) high. PSCO observed the port aft vapor manifold was painted in a sequence of gray/yellow/red and the word "VAPOUR" was painted yellow. 46 CFR 39.2001(h)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 23 July 2016
Resolution: Recieved Class report satisfying the requirements to clear the deficiency.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 21 July 2016 Resolved
1499- Other (Prop. & Aux. Machinery)-Where automatic starting is not required, manual starting is permissible, such as manually charged hydraulic accumulators, where they can be demonstrated as being effective. PSCO observed manual hydraulic start did not function on first 6 attempts. 74 SOLAS (04) II-1/44.4.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: After running the generator using battery start several times they hydraulic starat worked on the 7th attempt. PSCO returned 2 hours later and satisfactorily tested hydraulic starting system.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 21 July 2016 Resolved
2120- Garbage- Every ship shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for minimizing, collecting, storing, and disposing of garbage including the use of equipment on board. PSCO observed that plan did not include any ship specific information. MARPOL ANNEX V/10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 21 July 2016
Resolution: C/O added missing information to the satisfaction of PSCO.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 11 July 2012 Resolved
1510: The AIS Pilot Plug on each vessel over 1600 GT on an international voyage, must be available for pilot use. Pilot reported AIS Pilot Plug inoperable. Provide USCG w/ tech report for repairs.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 September 2012
Resolved 28 September 2012
Resolution: Received Tech report attesting to the proper operation of the vessels AIS system. Vessel had new AIS system installed. All tests fully operational.

Ownership record