Records from 2004 to 2022. Most recent: inspection, 3 November 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
3 November 2022
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7589085
2 November 2021
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7345838
10 June 2021
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7221303
6 June 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6707032
20 March 2019
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6646287
1 May 2018
Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6410477
12 April 2017
Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6123153
15 April 2016
COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5855235
20 June 2012
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4350272
29 April 2008
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3194593
19 June 2007
Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2966980
29 March 2007
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2897987
27 July 2006
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2726615
27 June 2006
Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2693503
4 April 2006
Hull Examination
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2617288
21 July 2005
Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2434793
3 June 2004
Initial Certification · Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2088664
20 February 2004
Construction Oversight · Simplified Stability Test
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2073367
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 August 2021
Resolved
No floating waterlight. One floating waterlight shall be attached with a corrosion resistant clip to a three(min) to six(max) foot lanyard secured around the body of the ring life buoy.
Vessel is limited to daytime operation until rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 2 November 2021
Resolution: To the satisfaction of the USCG.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2019
Resolved
At least one ring life buoy must be fitted with a lifeline. Vessel's ring life buoy did not have the required line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 18 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019
Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessel's submersible bilge did not operate properly in that it would not turn off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2019
Resolved 18 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2019
Resolved
The vessel must have a flammable vapor detection system in the gasoline fuel tank space. Detection sensor is no longer functioning as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2019
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2019
Resolved
The vessel is required to have on board the required number of portable fire extinguisher IAW the issued COI. Vessel did not have the required number of portable fire extinguishers. The vessel needs a BII portable fire extinguisher placed on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2019
Resolved 18 June 2019
Communications › Radio Communications › VHF Radiotelephone
Issued 15 April 2016
Resolved
Renew vessel's Radio Safety Certificate
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 1 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 27 June 2006
Resolved
Provide proof of FCC marine radio operators permit.
Due 1 August 2006
Resolved 29 March 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 27 June 2006
Resolved
Provide proof of FCC radio telephony safety certificate.
Due 1 August 2006
Resolved 27 June 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 June 2006
Resolved
Provide portable lighting IAW 46CFR 183.430
Due 7 July 2006
Resolved 27 July 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2005
Resolved
Renew expired items in first aid kit.
Due 7 August 2005
Resolved 21 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2005
Resolved
Label location of first aid kit and distress locations.
Due 7 August 2005
Resolved 21 July 2005
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 3 June 2004
Resolved
In accordance with § 182.455 (b)(6) install drip pan fitted with flame screen in way of strainer.
Action required: 705 - Other - as specified
Due 3 June 2004
Resolved 12 July 2004