Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named MV WHALING CITY EXPRESS
MV WHALING CITY EXPRESS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2014, most recently in April 2025, along with 41 deficiencies, 1 operational control and 5 casualty investigations between 2005 and 2022.
Records from 2005 to 2025. Most recent: inspection, 30 April 2025.
- Built
- 2004
- Last inspected
- 30 April 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 41 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2005–2022
Identity
1156934
9329370 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH9965
684970
Flag
UNITED STATES
367673370
Maury page id
psix-684970
Inspections, by type
…with no type recorded4
Years with a record
11 calendar years (2014–2025)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)82.6 ft × 28.0 ft × 11.0 ft
Registered tonnagegross 77 / net 52
ITC dimensions (L × B × D)82.6 ft × 28.0 ft × 11.0 ft
ITC tonnagegross 232 / net 76
BuilderKVICHAK MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 2004
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portATLANTIC HIGHLANDS, NJ
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Convention (Subpart B), Net Ton
52 - Regulatory (Subpart C or D), Net Ton
232 - Convention (Subpart B), Gross Ton
77 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
232 - Convention (Subpart B), Gross Ton
77 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH9965MMSI 367673370 · active · compulsorily equipped · granted 7 May 2025, expires 20 May 2035
WDB8159MMSI 366953970 · expired · compulsorily equipped · granted 4 June 2004, cancelled 9 August 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 25
30 April 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8124210
25 November 2024
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8039484
25 October 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8023926
2 April 2024
COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7862916
5 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7703428
22 November 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7596682
20 June 2022
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7485677
20 June 2022
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7491010
24 May 2022
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7457893
8 June 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7219792
12 November 2020
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7093228
14 May 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955150
18 April 2019
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6665389
11 October 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6563344
2 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6553249
28 September 2018
In-Service Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6552412
4 June 2018
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6417883
18 January 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6339679
5 June 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6148692
16 May 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6201126
30 March 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6114346
24 March 2017
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6110743
10 May 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5873381
12 August 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4952566
12 August 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4952649
Deficiency record · 41
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 April 2025
Resolved
Each vessel must be marked as required by part 67. Vsl name on Stbd bow did not match the vessels documentation.
46 CFR 185.602
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 June 2023
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Vessel's fire hatch IWO engine room entrance would not close as designed due to spring hinges being seized, must fix to new condition and prove operation.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 June 2023
Resolved
At each inspection the hull exterior and interior will be inspected for watertightness and integrity, vessel stern shell plate IWO port exhaust at the bottom is cracked, must submit repair plan and conduct proper repairs back to original design.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 June 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, vessels hatches were not marked properly must mark as per regulation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 June 2023
Resolved
Abandon-ship, man overboard, and fire drills shall be logged or otherwise documented for review by the CGMI, vessel had not logged drills in vessel log book however Captain had his own drills log book not for current vsl
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 June 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. On board kit does not meet the regulation, must get complete kit as per the regulation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; under bridge counsel a battery wired to a UPS which was using extension cords for hard wire situation, must only use proper wire (boat cable) and return to original approved drawings for this area or submit a plan for approval.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 5 June 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries; port MDE exhaust is missing insulation, must replace.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2023
Resolved
During man over board drill & fire drill the crew had no way to communicate with the Captain, as an alternative to the required rescue boat SPV's are allowed by the OCMI to have arrangements to recover a person in a timely manner (15 min ), & fire drills conducted sufficient to ensure crew is familiar with their duties;crew would need to leave the scene of the emergency and not have control of crowd during incident. Vessel must come up with a method for crew to communicate with Captain during drills.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 June 2022
Resolved
Fire main piping has a hole causing a water leak. Make effective permanent repairs to the satisfaction of CG marine inspector prior to movement.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 June 2021
Resolved
The float-free link must be secured to the painter at one end and to the vessel at the other. The float free link was found attached to the vessel at both ends.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 June 2021
Resolved
Each distribution panel or switch onboard must be totally enclosed and of the dead front type. Power panel was found with open slot.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 9 June 2021
Resolved
Rails and equivalent protection must be installed near the periphery of all decks accessible to passengers or crew. Front bow found missing railing.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 June 2021
Resolved
A storage cylinder must be installed to provide a space of at least 2 inches between the deck and the bottom of the storage cylinder. No space is provided between the deck and the storage bottom.
Rectify w/in 7 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2021
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned places. Port forward forepeak tank was not working at the operating station.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 November 2020
Resolved
#3 void under sea strainer, several isolated pits discovered on the keel plate. Deepest pit at 25% percent of ½ “plate thickness. Submit repair proposal/ arresting plan.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 12 November 2020
Resolved
Cracked Handrails, multiple locations on bow, 02 locations aft upper deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 November 2020
Resolved
Port side FWD engine room, repair fire block on cable run.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2020
Resolved
Port Forepeak, removed dead end wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 November 2020
Resolved
STBD Lazarrette, Bilge through hull valve seized.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 April 2019
Resolved
The EPIRB was not listed on the FCC Radiotelephony Certificate. EPIRB must be checked by FCC technician if carried onboard. (47 CFR 80.59)
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 April 2019
Resolved
Vessel position did not relay on VHF-DSC display. Since vessel is equipped with GPS, device should be connected to VHF for DSC capabilities. (47 CFR 80.905)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 April 2019
Resolved
CO2 pressure switch for engine shutdown did not operate for generator. A device must be provided to automatically shut down engines that draw intake air from the protected space prior to release of the extinguishing agent into the space.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 April 2019
Resolved
Remote pull for port engine room flap for ventilation does not actuate. Provisions must be made for closing all ventilation openings for a space protected by a fixed gas extinguishing system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 April 2019
Resolved
CO2 release instructions are missing. Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 April 2019
Resolved
STBD CO2 remote pull cable is deteriorated. Controls must be protected from damage & pull cable used to activate system controls must be enclosed in conduit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2019
Resolved
STBD Fire pump does not discharge at 60psi. The minimum capacity of the pump must be 50 gpm at a pressure of not less than 60 psi at pump outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2019
Resolved
Unable to test operation of port & stbd engine room and port & stbd laz space bilge pumps due to oil in bilge. At each inspection for certification, the operator shall be prepared to conduct operational test of the means provided for pumping bilges and have the vessel ready for inspection. Clean bilges to enable proper testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 April 2019
Resolved
Hydraulic hose fittings on stbd steering ram are deteriorated and need to be replaced.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 April 2019
Resolved
Rudder angle indicator arm joint is seized and unable to move freely.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 October 2018
Resolved
Clean, crop, and renew pitted hull platting in excess of 1/3 thickness of hull in first bay from forward bulkhead, first void space, starboard side.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 11 October 2018
Resolved
Repair cracked wet deck weld, starboard side, forward of collision bulkhead.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 11 October 2018
Resolved
Crop and renew hole in deck plating in port lazarette, 10 stiffeners from sideshell.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 October 2018
Resolved
Vsl is not broadcasting dimension information (AIS Antenna Position ABCD values equals 0)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 September 2018
Resolved
Vessel's three life-jacket storage units located on the aft upper deck are not properly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2018
Resolved
The port side bilge pump is inoperable, repair pump.
Construction/Loadline › Hull › Hull Plating
Issued 24 March 2017
Resolved
Vessel ran aground. Operators shall conduct a dry dock to assess potential damage to hull of vessel.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 24 March 2017
Resolved
Vessel ran aground and shall inspect port and starboard propellers for damage.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 24 March 2017
Resolved
Vessel must submit plan prior to getting underway for safe voyage to dry dock.
Engineering › Bilge Water Management System › Pump
Issued 24 March 2017
Resolved
Vessel must test bilge alarms and pumps prior to departure for dry dock.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 24 March 2017
Resolved
Bilges need to be cleaned of all oil and diesel.
Casualty record · 5
8 March 2005Routine · role: Involved in a Marine Casualty · activity 2318394
2 November 2009Routine · role: Involved in a Marine Casualty · activity 3890855
9 July 2013Routine · role: Involved in a Marine Casualty · activity 4656437
30 March 2017Routine · role: Involved in a Marine Casualty · activity 6114346
20 June 2022Routine · role: Involved in a Marine Casualty · activity 7491010
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.