Records from 2004 to 2025. Most recent: inspection, 24 October 2025.
Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 September 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Net Ton
735 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
24 October 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8258146
11 October 2024
Cargo Tank Internal · MTSA Verification · Internal Structural Exam · COI Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8006337
18 September 2023
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7793681
10 January 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6887245
5 August 2019
COI Inspection · Internal Structural Exam · Examination of Repairs · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6773587
21 August 2017
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6247560
15 August 2016
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5973314
11 May 2016
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5880533
21 July 2015
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5187888
11 July 2014
COI Inspection · MTSA Verification · Drydock Exam · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4913933
26 April 2012
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4295745
2 December 2011
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4200458
21 November 2011
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4192756
17 November 2011
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4190910
6 December 2010
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3905264
11 May 2010
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3733425
29 May 2009
COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3489301
19 May 2009
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3487882
19 September 2008
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3327998
28 September 2007
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3066506
20 June 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2685659
3 October 2005
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2507280
5 November 2004
Administrative Inspection
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2235291
29 July 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2149287
14 July 2004
Internal Structural Exam · Hull Examination · MTSA Verification · Initial Certification · Cargo Tank Internal
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2132557
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 17 November 2011
Resolved
make permanent repairs to suspected cargo tank leak IWO #2 wing void. You must obtain permission from this office prior to moving the barge from the Baton Rouge zone. Submit lightering plan to this office for approval prior to movement of the barge
Action required: 705 - Other - as specified
Resolved 2 December 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 11 May 2010
Resolved
Properly replace flame screen to teh #3 cargo tank hatch prior to cargo operation and by 17 May 2010.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2010
Resolved 11 May 2010
Resolution: Flame screen replaced.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 June 2006
Resolved
Provide satisfactory documentation to [name withheld]/Galveston that this vessel has operated in fresh water service at least 6 of the last 12 months. If the vessel has not been operated in fresh water service at least 6 of the last 12 months or satisfactory documentation cannot be provided, the vessel will be required to be inspected IAW the salt water intervals prescribed in 46 CFR 31.10-21(a)(1)
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 11 December 2006
Resolution: Statement of fresh water service and previous 6-12 month trip history provided.