MAURY USCG vessel records Sign in
← All vessels

CHEMTRANS SUN

CHEMTRANS SUN is a 2000 tank ship. The Coast Guard has recorded 55 inspections since 2000, most recently in January 2012, along with 12 deficiencies and 21 operational controls.

Records from 2000 to 2012. Most recent: inspection, 11 January 2012.

Built
2000
Last inspected
11 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9182655 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SINGAPORE
—
Maury page id
psix-6864

Inspections, by type

…with no type recorded35
Years with a record 13 calendar years (2000–2012)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it83744 - Displacement, Ton
69999 - Dead Weight, Ton
40516 - Convention (Subpart B), Gross Ton
20305 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BUNGE 14008 Freight Barge · MISLE 725218 · 28 February 2004 · activity 2018154

Inspection history · 55

11 January 2012 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4223143
9 December 2011 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4198195
3 February 2011 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3936324
4 January 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3919926
4 January 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3921686
15 November 2010 Deficiency Check · COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3889156
20 October 2010 COC-TVE Renew · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3873946
16 January 2010 MARPOL Annex VI Survey · NPV Safety Exam · ISPS I Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3659490
6 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3659491
21 March 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3437531
10 February 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3415474
25 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3399737
18 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3396242
8 January 2009 Ballast Water Examination · ISPS I Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3388650
6 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3389566
5 January 2009 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3390144
30 December 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3386537
20 October 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3347164
8 January 2008 Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 3127913
9 November 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3123556
10 October 2007 COC-TVE Annual · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3074323
27 July 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3008911
27 March 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2895906
26 March 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2891309
5 February 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2867374
31 January 2007 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2864728
26 January 2007 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2862090
20 January 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2858949
2 September 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2766521
2 September 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2860430
19 August 2006 COC-TVE Renew · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2752940
27 June 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2693530
23 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2591096
27 November 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2574240
8 August 2005 Ballast Water Examination · MARPOL Annex I Examination · Deficiency Check · MARPOL Annex V Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2455511
13 March 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2309044
13 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2309060
15 August 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2177138
17 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2136272
16 July 2004 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2135709
18 April 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2046621
28 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2015400
28 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2018154
6 May 2003 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1792631
8 February 2003 MARPOL Annex I Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1743992
13 January 2003 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1727982
6 May 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1613386
29 April 2002 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1608295
11 October 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 294658
8 May 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1464375
7 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 289830
11 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 52701
11 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 278920
8 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 278747
10 January 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 285939

Deficiency record · 12

Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 9 December 2011 Resolved
1835-Cargo vent system-The condition of the ship and its equipment shall be maintained to ensure that the ship in all repects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO discovered temporary epoxy repair on the mast head riser water drain line. Provide documentation from certifificate issuing authority attesting to acceptability of patch. SOLAS 74a, I/11.
Action required: 705 - Other - as specified
Due 9 January 2012
Resolved 11 January 2012
Resolution: Received class report attesting to satisfactory repairs made to the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 January 2011 Resolved
The vessel lost propulsion due to suspected stuck exhaust valve. Operational control issued. Vessel required to submit documentation from Class (ABS) verifying repair and satisfactory operation of propulsion system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2011
Resolution: ABS conducted a damage survey on the vessel and verified that the deficiency had been rectified. The chief engineer renewed the no. 3 exhaust valve with a spare. A dock trial of the main engine was conducted for dead slow ahead and astern. All sat.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 20 October 2010 Resolved
As per 46CFR32.59-10, IGS Instruction Manual must include procedures relating to vapor collection operations if connected to the vapor collection system. Vapor collection operations procedures are omitted from the IG manual.
Action required: 705 - Other - as specified
Due 19 November 2010
Resolved 15 November 2010
Resolution: PSCO Reviewed IGS Instruction Manual. Manual was found to include procedures relating to vapor collection operations as per 46 CFR 32.59-10.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 October 2010 Resolved
Electrical equipment fitted in enclosed cargo spaces shall be of a safe type for use in dangerous environments. Explosion proof lighting cover has a crack that will potentially eliminate its explosion proof capability. - SOLAS II-2/Reg. 19.3.2
Action required: 705 - Other - as specified
Due 19 November 2010
Resolved 1 December 2010
Resolution: TECH REPORT RECEIVED VIA EMAIL.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 20 October 2010 Resolved
Incinerators shall meet MARPOL requirements refraction incinerator fire door is worn and in need of replacement. - MARPOL ANNEX VI; Reg. 16.2(a)
Due 20 October 2010
Resolved 20 October 2010
Resolution: Refractory replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 20 October 2010 Resolved
Oil tankers of 150 gross tonnage and above shall be equipped with an oil discharge monitoring and control system approved by admin. Vessel's ODME overboard discharge valve hydraulic line fitting broke, rendering the valve inop. - MARPOL ANNEX I, Reg. 31.1
Due 20 October 2010
Resolved 20 October 2010
Resolution: Repaired while onboard. Valve operates.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Camshaft
Issued 16 January 2010 Resolved
1430- Auxiliary Engines- All 3 ship's service generators were not capable of operating at rated capacity. The #2 generator was found leaking a significant amount of lube oil at the rear main seal; cardboard boxes were placed up against the #2 generator to avoid lube oil from being thrown onto adjacent generator; collecting on the cardboard and deck. SOLAS II-1/41.
Action required: 705 - Other - as specified
Due 16 January 2010
Resolved 11 February 2010
Resolution: Received, reviewed and approved class report from ABS rectifying deficiency. Class report stated: all 3 auxiliary engines were completely overhauled; all worn parts were replaced; each generator ran at over 540kw and parameters checked. See narrative.
Engineering › Diesel Engine (propulsion-electric) › Cylinder
Issued 9 November 2007 Resolved
Received a report that the vessel's main engine started to run unevenly and didn't pick-up rpm from "slow ahead" to "half ahead".
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2007
Resolution: Received a class report attesting to the proper operation of the main engine
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 10 October 2007 Resolved
One of the fireman's outfit's fire retardant material is peeling, causing the effectiveness to fight fires to be compromised. Solas 2001 Reg 17/1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2007
Resolution: Conducted deficiency follow up on board vessel and examined 01 satisfactory fireman''s outfit.
Lifesaving › Launching Appliances › Winch Brake
Issued 10 October 2007 Resolved
During the lowering of the starboard lifeboat the block and tackle for the remote release became detached from the dead man’s brake, making the lowering from inside the lifeboat impossible. The lifeboat is still capable of being lowered to serve its purpose. Solas (2004 Consolidated Ed. ) Reg 20/2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2007
Resolution: Conducted deficency follow up on board and examined a permanent repair to the block and tackle for the remote release.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 8 August 2005 Resolved
Ascertain why IGS piping just aft of scrubber, is being supported by a wire cable. To satisfaction on class surveyor.
Due 8 September 2005
Resolved 8 August 2005
Resolution: Received ABS class report (#NY631485) that cable was removed and a clamp was built to configure the piping and secure to the overhead angle.
Electrical › Electric Generation Source (emergency)
Issued 6 May 2003 Resolved
Repair starter solenoid on emergency generator and prove proper operation of starter during automatic start/change over to the satisfaction of the flag administration. One crewmember is to be assigned the duty to manually start emergency generator until repaired.
Action required: 15 - Rectify deficiencies by next port
Due 9 May 2003
Resolved 17 May 2003
Resolution: Rcvd ABS report. Cleared requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.