MAURY USCG vessel records
← All vessels

DAVID E

DAVID E is a 1952 towing vessel. The Coast Guard has recorded 9 inspections since 1994, most recently in July 2018, along with 21 deficiencies.

Records from 1994 to 2018. Most recent: inspection, 20 July 2018.

Built
1952
Last inspected
20 July 2018
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH7570
Flag
UNITED STATES
Maury page id
psix-68735

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded4
Years with a record 5 calendar years (1994–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)95.1 ft × 30.0 ft × 8.6 ft
Registered tonnagegross 271 / net 184
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING · STURGEON BAY, WI, UNITED STATES · built 1952
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLEMONT, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it271 - Regulatory (Subpart C or D), Gross Ton
184 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 9

20 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6561475
2 February 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2578182
30 January 2006 Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2576154
18 May 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2361711
12 May 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2360668
28 October 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2230391
22 October 2004 Deficiency Check · MTSA Verification · Uninspected Other
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2229858
22 August 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 644059
12 August 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 28955

Deficiency record · 21

Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 October 2004 Resolved
Provide proof of required tests and inspections IAW 33 CFR 164.78(b) and 33 CFR 165.80(a).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Master created log.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 22 October 2004 Resolved
Properly display EAP material IAW 46 CFr `6.401(a)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: EAP Posted
Documentation › Logs/Records › Drug Test Records
Issued 22 October 2004 Resolved
Properly post EAP information IAW 46 CFR 16.401(a).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2004
Resolved 28 October 2004
Resolution: EAP Posted
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 October 2004 Resolved
Obtain Local notice to mariners for area of operations IAW 33 CFR 164.72(b)(2).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: NTM on file
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 22 October 2004 Resolved
Provide current copy of Navigation Rules (Inland) IAW 33 CFR 88.05
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Current copy onboard
Communications › Audible Communications › Bell
Issued 22 October 2004 Resolved
Provide Bell with clapper, or install clapper on existing ships bell IAW Rule 33.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 October 2004 Resolved
Properly mark hailing port on stern of vessel IAW 46 CFR 67.123
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Name and hailing port on stern
Documentation › Markings/Placards › Official Number (US)
Issued 22 October 2004 Resolved
Properly affix Offical number of vessel IAW 46 CFR 67.121.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: O.N. Welded on main beam in engineroom.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 October 2004 Resolved
Post required MSD placard at device IAW 33 CFR 159.59 min 1/8" letters.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Placard posted on MSD.
Stability › Unintentional Flooding › General
Issued 22 October 2004 Resolved
Remove 2 feet of Fuel/Oil mixture from engineroom bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Fuel/Oil pumped out via vac truck.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 October 2004 Resolved
Prove proper testing of all employees and proof of enrolement in random program IAW 46 CFR 16.201
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Program sat record of pre-employment needed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 22 October 2004 Resolved
Produce fuel/oil transfer proceedures in compliance with 33 CFr 155.740 including PIC designations, and DOI's as required by 33 CFR 156.150
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Proceedures developed for vessel and reviewed.
Operations/Management › Drills/Instruction › Fire
Issued 22 October 2004 Resolved
Prove proper fire training of crew IAW 46 CFR 27.209
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Record of training dated 26OCT2004 produced.
Communications › Alarms/Indicators › General Alarm
Issued 22 October 2004 Resolved
Prove proper operation of general alarm and install required lights and placards in high noise areas IAW 46 CFR 27.205, 27.205(a)(3).
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Tested General alarm, operator installed strobes and placards in all high noise areas.
Communications › Alarms/Indicators › Fire Alarm
Issued 22 October 2004 Resolved
Obtain PE or Class review of fire detection system IAW 46 CFR 27.210
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 28 October 2004
Resolution: Owner of vessel obtained letter from ABS.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 22 October 2004 Resolved
Renew starboard forward flame screen.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 22 October 2004 Resolved
Remove trash from all crew berths.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: Trash cleared from all berths.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 October 2004 Resolved
Prove proper operation of remote fuel shut off valves, and properly label IAW 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2004
Resolved 28 October 2004
Resolution: All valves tested sat, proper labels installed
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 October 2004 Resolved
Provide guards and covers on all light fixures, distrubution panels and ensure globes are installed on all lights throughout the vessel.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2004
Resolution: All panel dead covers installed, globes on fixures, mats on deck areas.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 22 October 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 October 2004
Resolved 22 October 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses › Certificate, Radar Observer
Issued 22 October 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 October 2004
Resolved 22 October 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.