MAURY USCG vessel records
← All vessels

DELFINO

DELFINO is a 2004 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in January 2026, along with 34 deficiencies and 1 casualty investigation in 2017.

Records from 2016 to 2026. Most recent: inspection, 7 January 2026.

Built
2004
Last inspected
7 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN6581
688360
Flag
UNITED STATES
Maury page id
psix-688360

Documentation record

Registered dimensions (L × B × D)63.2 ft × 23.9 ft × 7.5 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOOPER MARINE INC · ST PETERSBURG, FL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 16 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Net Ton
44 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 34 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

7 January 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8291670
5 January 2026 Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8290161
13 March 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8093135
16 January 2024 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7850109
5 January 2024 Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7845799
26 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7670805
22 March 2022 Deficiency Check · Annual Inspection · Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7427267
10 December 2021 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7366112
26 March 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7164625
5 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968935
14 April 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6938867
11 February 2020 Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6906739
23 May 2019 Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6733950
6 December 2018 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6593080
8 February 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351794
14 November 2017 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6313872
25 September 2017 Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6274901
9 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6142810
8 May 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6141711
11 April 2017 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6122335
25 April 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5863240
19 January 2016 DAPI Audit · Examination of Repairs · Annual Inspection · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5799967

Deficiency record · 34

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 January 2026 Resolved
Only one pre-engineered fixed gas fire extinguishing system is allowed to be installed in each space protected by such a system. the engine rooms have a cross connected space just forward of the engine rooms. 46 CFR 181.420(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2026
Resolved 2 February 2026
Resolution: Observed cross connect properly installed to isolate protected spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2026 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. MI observed vessel's placard for the port fuel shutoff valve was faded. 46 CFR 185.608
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2026
Resolution: Vessel placed new label for the fuel shut off.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 7 January 2026 Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. MI observed no method to prevent the discharge of sewage. 33 CFR 159.7(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2026
Resolution: Vessel placed a lock around seweage discharge valve.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 March 2025 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. System was not installed. Cite: 46 CFR 181.405(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2025
Resolution: System was installed and tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here. One 2-A portable fire extinguisher was not serviced annually. Cite: 46 CFR 176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2025
Resolution: Portable fire extinguisher was serviced by third party, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 March 2025 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Vent from machinery space missing cap. 46 CFR 182.460(i)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 1 April 2025
Resolution: New ventilation cap acquired, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2025 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Fire station missing spanner wrench. 46 CFR 181.310(d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 1 April 2025
Resolution: New Spanner wrench acquired, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 January 2024 Resolved
Fire pump is down due to PORT main engine being inoperable. A fire pump may be driven by a propulsion engine. A fire pump must be permanently connected to the fire main and may be connected to the bilge system to meet the requirements of § 182.520 of this chapter.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2024
Resolved 8 July 2024
Resolution: Starboard engine was lit off as well as the fire pump, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 January 2024 Resolved
Bilge pumps are not able to be tested due to PORT main engine being inoperable. A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2024
Resolved 8 July 2024
Resolution: Satisfactory test of the bilge system was conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 January 2024 Resolved
Each life jacket must be marked with Type 1 retroreflective material. Marine Inspector found 02 children life jackets and 19 adult life jackets with retro material in disrepair. Replace retro material.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2024
Resolved 8 July 2024
Resolution: Retroreflective material was added to lifejackets, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 January 2024 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. Radio telephony certificate expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2024
Resolved 8 July 2024
Resolution: Radiotelephony certificate received.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 January 2024 Resolved
Vessel MMSI# is incorrect. A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2024
Resolved 8 July 2024
Resolution: MMSI installed in both radios.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 25 January 2024 Resolved
Compass is not illuminated. Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Except on a vessel limited to daytime operations, the compass must be illuminated.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2024
Resolved 8 July 2024
Resolution: Illuminated compass installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 January 2024 Resolved
04 areas of rotting wood. 01 area found STBD FWD corner area with rotted wood w/ mold growing. 2) 01 area found with rotted wood mid PORT. 3) 01 area found FWD Port side with rotted wood. 4) 01 area on PORT side of operation station with rotted wood. The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2024
Resolved 8 July 2024
Resolution: All rotten wood has been cropped and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2023 Resolved
At least one ring buoy must be fitted with a lifeline. Missing lifeline on ring buoy. 46CFR180.70(c)
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 26 April 2023
Resolution: Added life line to ring buoy while onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 April 2022 Resolved
Vessel is restricted from operating with passengers until annual inspection is fully complete and damage repairs are completed on hull and machinery and cleared by CG Marine Inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2022
Resolution: Vessel completed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 March 2021 Resolved
Vessels fire pump failed to work. Fire pump is required if under 65' AND more than 49 passengers are carried. Vessel is limited to 49 passengers and (3) fire buckets required onboard until satisfactory operation of pump is witnessed by USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 March 2021
Resolution: Conducted virtual inspection, all sat
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 March 2021 Resolved
Vessel did not have a magnetic compass onboard as required. Provide proof of a sutiable magnetic compass for marine use being onboard and permanently mounted at the primary operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 7 April 2021
Resolution: Recieved picture of sutiable compass for marine use mounted at the primary operating station. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2019 Resolved
Lagging on both exhausts were not satisfactory and need to be replaced with new lagging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2019
Resolved 16 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 January 2019 Resolved
Water-light casing attached to the ring life buoy has a crack and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2019
Resolved 16 February 2019
Construction/Loadline › Structures › Scuttle
Issued 2 May 2017 Resolved
Hatches on weatherdeck are only weathertight. Due to Lake, Bays and Sounds plus Limited Coastwise route permitted on COI, hatches need to be watertight. Install watertight hatches, install a 12" trunk around weathertight hatches, or have route changed to Lakes, Bays and Sounds. Securing devices need to be installed on hatches.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 29 March 2018
Resolution: Hatch made watertight.
Communications › Alarms/Indicators › High Water Alarm
Issued 1 May 2017 Resolved
Label all high water visaul alarms and make operational.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 9 May 2017
Resolution: All high water visual and audible alarms operational.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2017 Resolved
Make fist aid kit box watertight or replace.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 May 2017
Resolution: Replaced watertight box.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 May 2017 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 9 May 2017
Resolution: Emergency Instructions posted at ops station.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 April 2016 Resolved
Masthead light blocked by radar. Raise stand light is attached to at least to where it is visible from required arc of visibility.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Raised mast head light.
Stability › Watertight Integrity › General
Issued 7 April 2016 Resolved
Forward hatch where mooring lines are stowed is not secured closed allowing water ingress. Repair or replace hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Replaced fwd hatch cover with new.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 April 2016 Resolved
Ring buoy light battery is expired. Replace battery.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Battery replaced and tested.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 April 2016 Resolved
Aft deck box is not secured in place. Secure deck box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Aft deck box secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2016 Resolved
Wiring in both engine spaces not properly supported. Install metal supports at least every 24 inches where needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Supports added every 24 inches.
Fire Fighting › Fire Pumps › Arrangement
Issued 7 April 2016 Resolved
Hose on the intake side of the fire pump is deteriorated. Replace hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Hose was replaced with new.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2016 Resolved
One dead ended wire in aft of starboard engine compartment. Remove, reattach to missing light, or cap and enclose wire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Removed wiring.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 April 2016 Resolved
Covers over the belts on both engines were missing. Cover all rotating/moving machinery parts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Covers repaired and installed.
Engineering › Pressure Vessel › Relief Valve
Issued 7 April 2016 Resolved
Water heater relief valve is set to 150PSI. Replace with a relief valve set at 100PSI as discussed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Replaced valve with 100 psi safety relief valve.
Lifesaving › Hand Flares › Quantity
Issued 7 April 2016 Resolved
Vessel was missing two orange smoke flares. Get two new orange smoke or red hand flares.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 25 April 2016
Resolution: Purchased new orange flares.

Casualty record · 1

8 May 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6141711
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PORTOFINO I (2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.