Records from 1987 to 1995. Most recent: inspection, 20 October 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 21 January 1995
Resolved
Properly install insulation in passenger elevator on promenade deck, forward starboard side.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly repair opening in bulkhead for new wires in way of frame 143 starboard side of vessel.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly seal holes in draft stop in way of frame 206, starboard side, Maile deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly install draft stop in way of frame 106, port corridor, Maile deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 21 January 1995
Resolved
Prove proper operation of fire damper S-32 (supply to crew galley).
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Remove all rope, strings, hooks, etc. that are being used to hold fire screen doors open.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1995
Resolved
Provide proper emergency lighting in stairtower leading to aft void.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1995
Resolved
Demonstrate that the two SOLAS rescue boats required by the Pasenger Ship Safety Certificate are in compliance with Chapter III, regulation 1 of SOLAS 74/83, or replace with boats which are in compliance.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly insulate radio room on boat deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly install insulation in way of frame 67 on boat deck, port side corridor near ships office.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Have muster station lists updated to reflect the present crew positions that are assigned to the S/S MONTEREY.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly install insulation in way of new pipe installation in theater on "C" deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Make repairs to insulation in way of frame 196 on "A" deck in center corrider.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Make repairs to insulation in way of frame 190, in 3 person crew cabin, starboard side "A" deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Reinstall proper insulation at wire penetrations in way of frame 135 in_x001C_ engineers office on "A" deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly insulate inboard bulkheads of both bunkering stations on "A" deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Privide documentation that painted over heat detectors on all decks continue to meet the intended heat sensing temperature as per manufacturersspecifications or repair/replace painted heat detectors.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly install draft stops in main dining area on aloha deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Place updated Fire Control Plan on board showing correct location of Fireman's outfit locker located near frame 192, port side, aft, on Aloha deck and correct designation of all spaces on board.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Conduct fire drill & abandon ship drill to the satisfaction of attending USCG Marine Inspector.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Lifesaving
Issued 21 January 1995
Resolved
Demonstrate adequate training in lowering of lifeboats by all crew members assigned to lifeboat lowering detail during abandon ship drill.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Documentation
Issued 21 January 1995
Resolved
Provide copies of the SOLAS training manuals on board written in all crew languages.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1995
Resolved
Stow all non-USCG approved life jackets in a separate space oustside any present life jacket storage location until documentation is provided proving compliance with SOLAS 74/83 chapter III regulation 32.1 or remove same from the vessel.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1995
Resolved
Ensure embarkation lights for survival craft properly & promptly operate under both normal or emergency power.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1995
Resolved
Review adaquacy of emergency lighting in all interior muster stations & modify lighting so as to comply with SOLAS 74/83 chapter III regulation 11.4.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1995
Resolved
Survey vessel with only emergency lighting energized to ensure all lights designated as emergency lights function properly.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1995
Resolved
Replace all missing and broken light globes and light bulbs in paint lockerand bosun stores.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1995
Resolved
Provide documentation that all life jackets on board are in compliance withSOLAS 74/83 Chapter III regulation 32. Existing life jackets are approved under U.S. regulations for domestic voyages.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1995
Resolved
Relocate paint stowed in engineering spaces to a designated paint locker, one that has installed fire protection.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Navigation
Issued 21 January 1995
Resolved
Prove proper operation of manual emergency steering system controlled by the wheel in the steering machinery room.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1995
Resolved
Install insulation on exhaust pipes from the emergency generator.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1995
Resolved
Install machinery guards on exhaust ventilation fans in emergency generatorroom overhead.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Recharge fire extiguisher #38, located in the forward starboard corner of emergency generator room.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1995
Resolved
Re-install missing globes and guards on incandesent light fixtures throughout the vessel. Fixtures which are no longer in service must be removed or have the electrical wiring disconnected from the electrical supply source and tagged accordingly.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Remove all wood and combustible construction materials from the disco area,on "C" deck. (Plastic/vinyl covering on particle board/plywood and wood framing)
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 21 January 1995
Resolved
Lable ladder into exhaust trunk in bow thruster room on "C" deck as "No Escape".
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Reinstall insulation on bulkhead of shore excursion office on aloha deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Reinstall missing A-60 door over pursers desk at boundary of aft main stairtower on Aloha deck in accordance with approved fire safety plans.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Replace glass doors to Beauty shop, Library, Liquor store and Souvenir shopwith doors with the same fire rating as the bulkhead.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 21 January 1995
Resolved
Remove supplies and permanently close storage locker in aft main stair- tower on Aloha deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Remove all wood/combustible construction from gym area on "A"-deck space designated as a void on the fire safety plan. If space is to be used as a gym update fire safety plan accordingly and install approved bulkhead structure.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Replace glass door to gym on "A" deck with door of same fire rating as bulkhead.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Properly insulate bulkhead in way of frame 35 on Aloha deck.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 21 January 1995
Resolved
Review fire safety plan and correct to reflect current use/designation of spaces.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 21 January 1995
Resolved
PROVIDE SAFE MANNING DOCUMENT WHICH REQUIRES ADEQUATE MANNING FOR LIFE BOATS AND LIFE RAFTS.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1995
Resolved
Survey and repair the public address system to ensure adequate coverage of all accommodations spaces.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1995
Resolved
Remove combustible paneling construction from forward stairtower leading togym.
Condition: Unknown
Due 21 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1995
Resolved
Remove paint and combustibles from aft void to a designated paint locker orstore room as appropriate.
Condition: Unknown
Due 23 January 1995
Resolved 23 January 1995
Fire Fighting
Issued 18 February 1989
Resolved
ADJUST THE FIRE SCREEN DOOR AFT OF THE GALLEY TO ALLOW PROPER CLOSING.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Engineering
Issued 18 February 1989
Resolved
REINSULATE THE LOWER PORTIONS OF THE PORT BOILER STEAM DRUM ON BOTH THE FORWARD AND AFT ENDS WHERE THE INSULATION IS PRESENTLY MISSING.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Electrical
Issued 18 February 1989
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF THE EMERGENCY POWER MOTOR- GENERATOR SETS.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Engineering
Issued 18 February 1989
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF THE OILY WATER SEPARATOR.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Engineering
Issued 18 February 1989
Resolved
MAKE REPAIRS AND PROVE OPERATION OF THE SUBMERSIBLE BILGE PUMP FOR ALL COMPARTMENTS COMMON TO THE SUCTION MANIFOLD.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Fire Fighting
Issued 18 February 1989
Resolved
INSTALL MAGNETIC HOLD BACK DEVICE ON FIRE SCREEN DOOR 11 AND PROVE OPERATION TO A COAST GUARD INSPECTOR BY LOCAL AND REMOTE CONTROLS.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Fire Fighting
Issued 18 February 1989
Resolved
ADJUST FIRE SCREEN DOOR 77 TO ALLOW PROPER CLOSING.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Fire Fighting
Issued 18 February 1989
Resolved
PROVIDE DOCUMENTATION FOR THE APPROVED FIRE SAFETY PLAN WHICH WILL INDICATE WHY THE 3 HEAT SENSORS SHOWN ON THE APPROVED DRAWING IN THE "A" DECK HANDLING SPACE ARE NOT INSTALLED OR INSTALL AND DEMONSTRATE PROPER OPERATION OF THE 3 SENSORS.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 February 1989
Resolved
ADJUST AND PROVE PROPER OPERATION OF FIRE SCREEN DOOR 74.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Fire Fighting
Issued 18 February 1989
Resolved
INSTALL "Y" GATE HANDLE AT FIRE STATION 49 WHICH IS PRESENTLY MISSING.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Fire Fighting
Issued 18 February 1989
Resolved
REPLACE THE NON-APPROVED OR WRONG LENGTH HOSES ON FIRE STATIONS 21, 112 & 100 WITH UL APPROVED TO STANDARD 19 FIRE HOSES.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Fire Fighting
Issued 18 February 1989
Resolved
REPAIR AND PROVE OPERATION OF THE FIRE DAMPER CABLE FOR FIRE DAMPER 98.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Electrical
Issued 18 February 1989
Resolved
READJUST AND PROVE OPERATION OF THE OVERSPEED TRIPS ON SS GENERATORS 2-4, FOR A TRIP BETWEEN 1320 AND 1380 RPM.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Electrical
Issued 18 February 1989
Resolved
SUBMIT PLANS FOR APPROVAL OF THE EMERGENCY GENERATOR VENTILATION INTAKE DAMPER MODIFICATIONS.
Condition: Unknown
Due 18 May 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 18 February 1989
Resolved
REBRICK THE FRONT WALL OF THE STBD BOILER IN WAY OF THE BURNERS.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Engineering
Issued 18 February 1989
Resolved
CROP AND RENEW THE WASTED SECTION OF THE SOOT EJECTOR LINE LOCATED IN THE STACK SPACE STBD SIDE.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Engineering
Issued 18 February 1989
Resolved
MAKE PERMANENT REPAIRS TO THE CASING LEAKS ON THE STBD BOILER UPTAKE ON THEAFT SIDE EXPANSION JOINT & ON PORT BOILER AT CASING PENETRATION #8 SOOT BLWOUTBD SIDE EXPANSION JOINT, BOTTOM CASING IN WAY OF DRUM & UPTAKE EXPANSIONJOINT ON THE OUTBD AND AFT SIDE.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Fire Fighting
Issued 18 February 1989
Resolved
INSTALL FIRE DAMPER 103 IN GALLEY AREA IN ACCORDANCE WITH THE APPROVED PLANS OR PROVIDE DOCUMENTATION WHICH WILL INDICATE A VENTILATION DUCTING MODIFICATION WHICH WOULD ELIMINATE THE NEED FOR ITS INSTALLATION.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Engineering
Issued 18 February 1989
Resolved
PROVIDE INSULATION ON ALL PIPING, VALVES AND FITTINGS FOR SYSTEMS WHICH CONVEY GASES, VAPORS OR LIQUIDS WITH A SURFACE TEMPERATURE OF 150 DEGREES F. OR GREATER IN THE MACHINERY SPACES.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Electrical
Issued 18 February 1989
Resolved
RECALIBRATE THE FREQUENCY METERS ON THE MAIN SWITCHBOARD.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Engineering
Issued 18 February 1989
Resolved
PROVIDE REMOTE SUPERHEATER PRESSURE GAGES AT THE THROTTLE BOARD.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Electrical
Issued 31 December 1988
Resolved
PROVE PROPER OPERATION OF THE GROUP CONTROL MAIN BOARD FEEDER CIRCUIT BREAKER P-35 (500 AMP).
Condition: Unknown
Due 31 December 1988
Resolved 31 December 1988
Fire Fighting
Issued 17 December 1988
Resolved
MODIFY THE EMERGENCY GENERATOR RADIATOR AIR INLET DAMPERS TO REMAIN OPEN UNDER ANY POWER FAILURE SITUATION AND TO CLOSE ONLY WHEN FIRE OCCURES IN THE GENERATOR ROOM.
Condition: Unknown
Due 17 December 1988
Resolved 17 December 1988
Electrical
Issued 17 December 1988
Resolved
RENEW OR REPAIR THE INSTANTANEOUS TRIPS TO THE MAIN DISTRIBUTION BUS BREAKER E (1600 AMP BREAKER) AND THE GROUP CONTROL MAIN BOARD FEEDER CIRCUIT BREAKER P-35.
Condition: Unknown
Due 17 December 1988
Resolved 17 December 1988
Engineering
Issued 25 October 1988
Resolved
CLEAN UP ALL OIL FROM BOTH FUEL PORTS, POST OIL TRANSFER PROCEDURES WITH A ONE LINE PIPING DIAGRAM IN THE STBD FUEL PORT AND REPAIR THE LIGHT SWITCH AND CAP THE 4 INCH VENT IN THE STBD FUEL PORT.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Engineering
Issued 25 October 1988
Resolved
PROVIDE HAND RELEASING DEVICE FOR THE LP STEAM GENERATOR RELIEF VALVE.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Engineering
Issued 25 October 1988
Resolved
REPAIR AND PROVE OPERATION OF THE REACH ROD VALVE FOR #5 DEEP TANK INBOARD STBD.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
PROVIDE ADDITIONAL PERMANENT STORAGE RACKS FOR FREON BOTTLES.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Engineering
Issued 25 October 1988
Resolved
RECALIBRATE AND PROVE OPERATION OF ALL FUEL OIL SYSTEM KING GAGES.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Engineering
Issued 25 October 1988
Resolved
RECALIBRATE AND PROVE OPERATION OF THE REMOTE WATER LEVEL GAGES ON THE BOILER CONTROL BOARD.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988
Resolved
REPAIR AND PROVE OPERATION OF THE FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
REMOVE ALL NON-STANDARD LOCKS FROM VARIOUS COMPARTMENT DOORS AND INSTALL LOCKS ON THE MASTER KEY SYSTEM.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988
Resolved
PROVIDE KEEPER FOR FIRE DAMPER #503.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Electrical
Issued 25 October 1988
Resolved
PROVIDE CIRCUIT DIRECTORY FOR POWER PANEL 21-P24.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988
Resolved
REINSTALL PULL CABLE FOR FIRE DAMPER 196.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Construction/Loadline
Issued 25 October 1988
Resolved
INSTALL ADDITIONAL INSULATION OVER THE BOILER UPTAKES IN STACK SPACE IN WAYOF THE CAT WALK.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
BALANCE FAN ASSEMBLE FOR THE PORT GALLEY SUPPLY FAN.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
PROVIDE PERMANENT FOUNDATION AND PROVIDE UL APPROVED CONTROLLER FOR THE COMPRESSOR UNIT FOR THE GALLEY CHILL BOXES AND MOUNT CONTROLLER ON BULKHEAD
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Navigation
Issued 25 October 1988
Resolved
TIGHTEN ALL LEAKY COMPRESSION FITTINGS ON STEERING GEAR UNIT, PROVIDE SOUND POWERED PHONE OUTLET AT EMERGENCY STEERING STATION, AND REMOVE ALL HYDRAULIC OIL FROM STEERING ROOM DECK AND MAINTAIN FREE OF OIL AT ALL TIMES.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
PROVIDE SAFETY GUARD OVER THE TURBINE/COMPRESSOR COUPLINGS IN THE AUX. MACHINERY SPACE.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
PROVIDE PIPE SUPPORT FOR GRAY WATER LINE LOCATED IN VOID SPACE STBD SIDE B DECK.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
CLEAN ALL JUNK AND TRASH FROM ENTRANCE TO THE ENGINEERS STORE ROOM.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Engineering
Issued 25 October 1988
Resolved
INSTALL SCREENS OVER THE BILGE WELLS FOR #1 ELEVATOR WELL, THE BOW THRUSTERCOMPARTMENT, AND #2 HOLD AND RECONNECT AND PROVE OPERATION OF ALL BILGE MANIFOLD REACH ROD VALVES.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Accommodation/Occupational Safety
Issued 25 October 1988
Resolved
CLEAN AND MAINTAIN IN A SANITARY CONDITION THE MAIN GALLEY.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988
Resolved
REPAIR AND PROVE OPERATION OF THE FIRE DETECTORS IN LOCKER AFT OF BRIDGE, STBD SIDE, ALARM SWITCH ON PROM DECK NEAR DOOR TO LB 4&6 MISSING GLASS, IONDETECTOR BROKEN ON MAILE DK FWD THWARTSHIP PASS., SENSOR IN LOCKER P-2 PROMDK, AND SENSORS IN A DECK VOID AND LOCAL ALARM IN C DK LAUNDRY RETEST.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988
Resolved
PROVIDE FIRE HOSE AND RACK FOR FS#112 AND HOSE RACK FOR FS#100. 24 HOUR FIRE WATCH TO BE MAINTAINED IN THESE AREAS UNTIL ITEMS ARE CORRECTED. ALSO REQUIRE 2 EXTRA B-II PORTABLE FIRE EXTINGUIHERS BE PROVIDED AT FS # 112 UNTIL FIRE HOSE IS INSTALLED.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988
Resolved
REPAIR AND PROVE OPERATION OF THE FOLLOWING FIRE SCREEN DOORS: 39, 41, 58 77 & 23. LABEL FSD # 71 & 72 AS PER FIRE CONTROL & SAFETY PLAN AND REMOVE LABELS FROM 2 DOORS PRESENTLY MARKED. 24 HOUR FIRE WATCH TO BE MAINTAINED IN THESE AREAS UNTIL ITEMS ARE CORRECTED.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 25 October 1988
Resolved
PROVIDE TEMPORARY DOOR IN TRANSVERSE PASSAGEWAY TO SIDE PORTS AND REPLACE WITH A FIRE SCREEN DOOR LABEL #75 WHICH WILL MEET THE REQUIREMENTS OF 46 CFR 72.05-25. 24 HOUR FIRE WATCH TO BE MAINTAINED UNTIL ITEM CORRECTED.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Lifesaving
Issued 25 October 1988
Resolved
PROVIDE 7 ADDITIONAL CANS OF WATER FOR LB # 2, AND LUBRICATE THE FAIR LEAD ROLLER SHAFTS.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Construction/Loadline
Issued 25 October 1988
Resolved
MAKE REPAIRS AND PROVE OPERATION OF THE BRIDGE PANEL LIGHTS FOR W.T.D. #8 AND THE WARNING HORN LOCATED IN THE VICINITY OF THE DOOR FOR W.T.D. #10.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Unknown
Issued 12 September 1988
Resolved
REPAIR SECURING LATCH ON SLIDING DOOR TO PORT SIDE IN THE PILOTHOUSE.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Fire Fighting
Issued 26 August 1988
Resolved
PRIOR TO SAILING ON AN INTERNATIONAL VOYAGE, PROVIDE THREE FLAME SAFETY LAMPS AND 1 QUART OF NAPTHA FOR EACH.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Lifesaving
Issued 26 August 1988
Resolved
INSTALL GUARDS (WIRE MESH) ON LIFEBOAT DAVIT TRACKS (DAVITS 1-6).
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Unknown
Issued 25 August 1988
Resolved
INSTALL PROPER PAINTERS ON ALL SIX LIFEBOATS WHICH MEET THE REQUIREMENTS OF46 CFR 75.20-15(Z). SHALL BE COMPLETED AND SATISFACTORILY DEMONSTRATED TO THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTING THE PORT OF NEWPORT NEWS, VA.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PROVIDE KEEPERS TO HOOKS ON BLOCKS TO BOWSING IN EACH LIFEBOAT.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PROVIDE CLEAT OR RING TO SECURE AFT BOWSING GEAR TO #4 LIFEBOAT TO VESSEL.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
SLUSH ALL LIFEBOAT FALLS AND FALLS FOR LIFERAFTS LAUNCHED BY DAVITS.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
INSTALL FAIR LEADS AND DEMONSTRATE SATISFACTORY OPERATION ON ALL BOAT DAV- ITS TO PREVENT TRICING PENDANTS FROM CATCHING ON BOAT BUMPERS. THE FIX IN-STALLED AT BETHLEHEM STEEL S/Y CURRENTLY ON THE DAVITS DID NOT SOLVE THIS PROBLEM ORIGINALLY DISCOVERED AT INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PROVIDE SIX FLAME SAFETY LAMPS.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PRIOR TO DEPARTING NORFOLK, VA, CONDUCT ABANDON SHIP DRILL IN THE PRESENCE OF A MARINE INSPECTOR TO HIS SATISFACTION.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
INVESTIGATE CAUSE OF FWD HAND PUMP ROTATION FOR SLIDING WATERTIGHT DOOR #17WHEN SYSTEM IS OPERATING BY POWER. OVERHAUL OR REPLACEMENT OF HYDRAULIC BLOCK VALVE AT DOOR MAY BE NECESSARY.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PROVIDE THE FOLLOWING REVISED PLANS APPROVED BY THE MSC TO THE [name withheld]: A. GENERAL ALARM SYSTEM AND SAFETY PLAN SHOWING THE ADDITIONAL 28 GENERAL ALARM BELLS; B. ELECTRICAL INSTALLATION DRAWING FOR THE NEW SHOP AREAS ON MAIN DECK FRAMES 86-106.
Condition: Unknown
Due 21 September 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 25 August 1988
Resolved
DEMONSTRATE PROPER OPERATION OF THE VESSELS MARINE SANITATION DEVICE. SYSTEM WOULD NOT OPERATE PROPERLY IN FRESH WATER. CERTIFICATION IN WRITINGBY THE VESSEL'S [name withheld] WORKS PROPERLY UNDERWAY WILL SATISFY THIS REQUIREMENT.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
MARK BUOYANT APPARATUS WITH VESSEL'S NAME AND PERSON CAPACITY.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
RELABEL ELEVATOR INDICATORS FOR ALL THREE ELEVATORS ON ALL DECKS WITH PERM-ANENT LABELS OR MARKINGS TO CORRESPOND WITH THE NEW DECK NAMES.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PROVIDE TECHNICIANS REPORTS FOR THE BOILERS COMBUSTION AND FEEDWATER CON- TROLS TO THE [name withheld] THIS SHOULD BE CERTIFICATION IN WRITINGBY THE VESSEL'S [name withheld] SYSTEM'S OPERATE PROPERLY.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
CONNECT AND PROVE PROPER OPERATION OF SIX DISHWASHERS LOCATED ON THE PROM- ENADE DECK, UPPER DECK, MAIN DECK, CONFERENCE CENTER, CREW MESS AND AFT UPPER DECK PANTRY.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
INSTALL LICENSE RACK.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PROVIDE PAINTER TO EACH BUOYANT APPARATUS WHICH IS THREE TIMES THE DISTANCEFROM THE DECK ON WHICH IT IS STORED TO THE LIGHTEST DRAFT WATERLINE IN LENGTH.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 25 August 1988
Resolved
PROVIDE PENDANTS TO INSIDE PERIMETER OF EACH BUOYANT APPARATUS. PENDANTS SHALL BE 12' LONG, SECURED IN THE MIDDLE, 1/4" IN DIAMETER AND 540 POUNDS BREAKING STRENGTH AND SPACED EVERY 18".
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Engineering
Issued 1 June 1987
Resolved
16" AUXILLIARY CIRCULATION OVERBOARD LINE HAS A TEMPORARY WELDED PATCH WHERE HOLED THROUGH INSIDE THE ADJACENT COFFERDAM. HULL PENETRATION AT THESIDESHELL HAS BEEN BALNKED OFF.
Condition: Unknown
Due 1 June 1987
Resolved 1 June 1987
Engineering
Issued 1 June 1987
Resolved
AFT PEAK BILGE SUCTION VALVE IS WASTED DUE TO CORROSION AND REQUIRES RENEWAL.
Condition: Unknown
Due 1 June 1987
Resolved 1 June 1987