Records from 1997 to 2024. Most recent: inspection, 7 October 2024.
Inspection history · 18
7 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7990431
26 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7790879
21 November 2022
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7597645
20 September 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7536144
18 August 2021
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7290114
13 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7232502
9 July 2020
Deficiency Check · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6971949
2 August 2019
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6788402
26 October 2017
Industry Initiated Exam · Administration · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6298205
8 January 2015
Industry Initiated Exam · Administration
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5052011
4 November 2014
DAPI Audit · Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5018304
11 November 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4188080
2 June 2011
Industry Initiated Exam · Administration · DAPI Audit
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4031935
9 June 2010
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3800625
23 February 2010
Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3687680
21 April 2000
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 182506
1 May 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 49829
1 May 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 404241
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 October 2024
Resolved
The following systems must be equipped with gauges at the machinery location:
(1) Main engine lubricating oil pressure and main engine RPM;
(2) Main engine cooling water temperature;
(3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM;Generator was missing Oil Pressure gauge and RPM read out.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 30 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 October 2024
Resolved
The portable fire pump must be self-priming and power-driven, with:
(1) A minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge. Portable pump would not self prime.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 30 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. Electrical outlet was missing its cover FWD bulkhead main deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 30 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 October 2024
Resolved
46 CFR 141.375 (a) A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 for specified areas where the vessel operates. Flares on board were expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2024
Resolved 30 October 2024
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 7 October 2024
Resolved
Fueling procedures were faded. Replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2024
Resolved
Vessels Ring Buoys luminant tape was faded. Replace with approved tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 30 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2023
Resolved
Each towing vessel must have a fire-detection system installed. The system is installed, tested, and maintained in accordance with the manufacturer’s design manual.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 16 October 2023
Resolution: Their fire-detection system as been properly installed.tested, and maintained in accordance with the manufacturer’s design manual.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 September 2023
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. The flanking rudder post had a broken weld around the post. When rudder was used the deck would flex.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2023
Resolved 16 October 2023
Resolution: The flanking rudder post was welded around the post.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 September 2022
Resolved
The fire detection system must draw power from two sources. Fire detection system not operating properly . Getting alarm under AC power. 46 cfr 142.330
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 27 October 2022
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 September 2022
Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. Emergency duty station not posted in pilot house. 46 cfr 140.405(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 September 2022
Resolved
Each towing vessel must be equipped with at least two portable, battery-powered lights. One must be located in the pilothouse and the other at the access to the engine room. No emergency flashlight in pilot house. 46 cfr 143.410(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Exposed wires in overhead of Starboard side aft engine room. 46 cfr 143.205
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Mid ship forward engine room battery post corroded and cable end frayed. 46 CFR 143.205
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 September 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. bilges were found to be full of oil and debris. 46 cfr 142.220
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 September 2022
Resolved
Mechanical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard main engine air compressor feeds horn is inoperable. 46cfr143.205
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 20 September 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217. Meet the requirement or remove berthing. 46 cfr 142.330
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 20 September 2022
Resolved
Each towing vessel must be fitted with a general alarm that: is capable of notifying persons in any accommodation, work space, and the engine room. The general alarm in the second deck berthing space is not operable. Meet the requirement or remove berthing. 46 cfr 143.235
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2022
Resolved
Maintenance records for readiness and testing of machinery alarms and pressure relief valves are missing. Owner must insure all applicable items listed in the 143.245(b) table are completed and logged. 46CFR143.245
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 21 November 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2021
Resolved
Each vessel must have either a self priming, power driven, fixed or portable fire pump. Vessels portable fire pump would not pull suction without manual priming.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 10 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2021
Resolved
Portable fire extinguishers are required to be inspected monthly. Owner/Operator shall conduct monthly inspections and log.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 10 August 2021
Navigation
Issued 1 May 1997
Resolved
M/V BMW DID NOT HAVE CURRENTLY CORRECTED MARINE CHARTS ON BOARD.
Condition: Unknown
Due 1 July 1997
Resolved 9 June 1997
Navigation
Issued 1 May 1997
Resolved
M/V BMW DID NOT HAVE ANY COAST GUARD LOCAL NOTICE TO MARINERS ON BOARD.
Condition: Unknown
Due 1 June 1997
Resolved 2 June 1997
Navigation
Issued 1 May 1997
Resolved
M/V BMW DID NOT HAVE A COPY OF A COAST GUARD LIGHT LIST ON BOARD.
Condition: Unknown
Due 1 July 1997
Resolved 9 June 1997
Lifesaving
Issued 1 May 1997
Resolved
M/V BMW DID NOT HAVE A PROHIBITED DISCHARGE WARNING PLACARD.
Condition: Unknown
Due 1 June 1997
Resolved 2 June 1997
Lifesaving
Issued 1 May 1997
Resolved
M/V BMW DID NOT HAVE REQUIRED MARPOL PLACARD.
Condition: Unknown
Due 1 June 1997
Resolved 2 June 1997