MAURY USCG vessel records
← All vessels

ISLENO

ISLENO is a 2004 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in May 2022, along with 61 deficiencies — 4 with no resolution recorded —, 6 operational controls and 8 casualty investigations between 2009 and 2014.

Records from 2009 to 2022. Most recent: inspection, 3 May 2022.

Built
2004
Last inspected
3 May 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 May 2022
…past their stated due date3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9341201
WDH4396
690471
Flag
UNITED STATES
Maury page id
psix-690471

Documentation record

Tonnage as PSIX records it164 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
528 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

29 inspections, each with its date, unit and type; 61 deficiencies with the resolution recorded against each; 6 operational controls with the dates imposed and removed; 8 casualty investigations, with date and classification; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

3 May 2022 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7442994
28 December 2021 Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7373244
26 December 2021 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7372666
11 June 2021 MTSA Verification · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7222180
19 March 2021 Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7159378
27 February 2021 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7147480
29 June 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6986270
4 May 2020 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6948999
27 April 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6944628
27 January 2020 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6897046
26 December 2019 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6879181
25 July 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6762201
9 April 2019 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6656368
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512616
15 August 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6513863
27 April 2018 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6400873
20 March 2018 Deficiency Check · Damage Survey · Plan Review (Other than "T") · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6375501
17 January 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6341288
12 January 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6337266
6 December 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6320788
28 September 2017 Deficiency Check · Special
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6284222
15 June 2017 Annual Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6176970
19 May 2017 Examination of Repairs · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6152154
8 April 2017 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6120269
23 May 2016 Welding Related Inspections Qualification Testing · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5887752
19 May 2016 Annual Inspection · Deficiency Check · DAPI Audit · MTSA/ISPS Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5885692
13 April 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5853738
11 April 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5885310
12 February 2016 Examination of Repairs · Drydock Exam · Welding Related Inspections Qualification Testing · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5815479

Deficiency record · 61

11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 3 May 2022 No resolution recorded
Vessel's life raft serviciablity expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2022 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is outside their 3 month annual inspection window.
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 December 2021 Resolved
Elbow piping connection on #2 MDE was found excessively leaking
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 December 2021
Resolved 26 December 2021
Resolution: New pipe fittings where installed and avidence was provided of their leak-free condition.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 June 2021 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties that requires abandoning ship. The vessel crew was not aware and had not received training on their emergency duties and failed to perform satisfactorily during the abandon ship drill
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2021
Resolution: Conducted satisfactory abandon ship drill. All satisfactory
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 June 2021 Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The vessel does not have all the necessary charts f or the vessel 's area of operation- In addition, the other charts on board the vessel have not been corrected.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2021
Resolution: Verified all appropriate charts were on board and corrected.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 June 2021 Resolved
A door in a fire control boundary must meet the appropriate structural fire protection requirements as required by the vessel plans. The vessel replaced 6 doors in the last dry dock and the fire boundary specifications have not been provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2021
Resolution: Verified doors meet the appropriate fire boundary requirements.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 June 2021 Resolved
The hull and structural bulkheads and decks must be composed of steel or equivalent material and be properly insulated. In the machinery space, starboard side, between frames 3 and 4 (in the space) there was a section of about 1' x 1' of missing structural fire protection insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 June 2021 Resolved
Combustible insulation may be used for pipe and machinery covering or lagging within a machinery space, or used in an individual refrigerator box if the refrigerator box was purchased with the insulation already installed. Bridge penetration in way of the refigerating unit needs to be properly insulated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 June 2021 No resolution recorded
Repairs or alterations to equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The vessel owner/operator replaced 02 air conditioning units (not in kind) without the knowledge or approval of the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 11 June 2021 No resolution recorded
The owner of the vessel shall submit for approval to the Marine Safety Center copies of the fire protection and life saving equipment, on board the vessel (fire control plan). The vessel's fire control, life saving, and passenger evacuation plans (all encompassed into one) are out of date and does not correspond to the equipmetn on board the vesssel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2022 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2021 Resolved
All electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. The distribution panel in the number 2, FWD void had empty breaker slots that were not blanked off or in use.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 June 2021 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation must be to the satifisfaction of the [name withheld] the torn fire extinguisher signage in FWD main deck passenger area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2021
Resolution: Placard placed in required area.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 June 2021 Resolved
The marine empoyer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a serious marine incident. Existing alcohol detection swabs on board were found to be expired in 28FEB2021. Replace with current alcohol swabs or other DOT approved alcohol detection devices as appropiate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2021 Resolved
Propulsion machinery must be suitable for the propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Main diesel engine number 2 (port inboard) was found to have a check engine alarm displaying the problems with a sensor. Prove proper operation of Main Diesel Engine #2.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2021 Resolved
An EAP education program must include training. The training program must inlcude at least the following elemnets: the effects and consequences of drug and alcohol use in personal health, safety and work environment; the manifestation and behavioral cues that may indicatedrug and alcohol use and abuse; and documentation of training given to crew members and employer's supervisory personnel. Training records showed no evidence that the vessel captain has taken a recen DAPI training. Also, captain failed to answer correctly the testing required timeframe in accordance with the regulation to test for drug and alcohol after a serious marine incident.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2021
Resolution: Training was conducted, captain re-interviewed. All satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2021 Resolved
Master of a vessel shall have examined and tested the steering gear prior getting underwaysfor a voyage. Vessel steering ram was found to be leaking. Properly correct leak and prove proper operation of the steering apparatus.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 11 June 2021 Resolved
Each vessel inspected and certificated under the provision s of 46 CFR 144 Subchapter K must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the Certificate of Inspection (COI). Vessle was fund not having an updated Senior Deckhand and Engineer designations letters, showig the recent changes in personnel in operations of the vessels as required by the current Certificate of Inspection. Update the Senoir Deckhand and engineer designation letter with current personnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2021 Resolved
At least one ring buoy must be fitted with a floating waterlight, unless the vessel is limited to daytime operation, in that case no floating waterlight is required. Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The life bouy waterlight lanyar was metal and rigid.
Action required: 10 - Deficiency Rectified
Resolved 1 July 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 June 2020 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Vessel's Steering gear seals on both PORT and STBD, bolts need to be tightened, and new bolts provided on broken bolts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 9 October 2020
Resolution: All 8 bolts were found to be secure, some by the installation of another nut to secure the first nut in place.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. In forward space below the main deck there is a hole in the deck on the STBD side near the overhead and side shell.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2020
Resolved 1 June 2021
Resolution: Verified repair completion during drydock period.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (i) Test of machinery alarms including bilge high level alarms. Bilge alarm was working but not attached to the bulkhead
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 June 2020
Resolved 29 June 2020
Resolution: Cleared on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following:(a) Operation of the main propulsion machinery both ahead and astern. #2 MDE port side more inboard engine has a leak fracture overboard discharge piping.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 June 2020
Resolved 29 June 2020
Resolution: Cleared on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following:(a) Inspection of all cable "as far as practicable, without undue disturbance of the cable or electrical apparatus. Loose ground wire on STBD Generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 June 2020
Resolved 29 June 2020
Resolution: Cleared on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 29 June 2020 Resolved
(a) At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Fishhooks and substantial deterioration was found on stern ramp port side on wire rope.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 June 2020
Resolved 29 June 2020
Resolution: Cleared on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 29 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (g) Operational test of all overboard discharge and intake valves and watertight bulkhead pipe penetration valves. Brackets for reach rod in steering room are not attached to the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 June 2020
Resolved 29 June 2020
Resolution: Cleared on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 29 June 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. On #1 MDE, replace, deteriorated coolant flexible hose flexible rubber hose for coolant.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 June 2020
Resolved 29 June 2020
Resolution: Cleared on the spot.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 27 April 2020 Resolved
46 CFR 176.306. When, in accordance with §178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessels' Stability Letter must be on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2020
Resolved 27 April 2020
Resolution: Cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 December 2019 Resolved
Repairs or alterations to the hull,that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to the replacement, repair, or plating, and structural members; repair of plate or frame cracks. During the damage survey inspectors found an indent of approx. 4-5 inches along a 4-5 foot section in the #2 void (pump room void) along the starboard side. The fourth frame back from fwd WTBH was crushed approx. 15-20% and some bending was also noted. A small fracture in the frame is seen where the #1 side stiffener runs through the frame. #1 side stiffener is warped between the fourth frame and the aft WTB. Provide repair proposal to [name withheld] and effect repairs once proposal has been approved within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2020
Resolved 1 June 2021
Resolution: Verified repair completion during drydock period.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 March 2019 Resolved
Fire control plan does not reflect current egress routes/emergency exits/life jacket stowage locations/portable extinguisher locations. Revise fire control plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 17 April 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 March 2019 Resolved
Emergency exits not properly marked. Properly mark all emergency exits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 17 April 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 March 2019 Resolved
Fire damper indicator lights non-operational. Repair and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 17 April 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 March 2019 Resolved
Fire damper pull port side not permanently mounted. Permanently mount.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 17 April 2019
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 29 March 2019 Resolved
Overspeed alarms and shutdowns unable to be demonstrated . Jacket water temperature shutdowns unable to be demonstrated. Demonstrate shutdowns and alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 18 April 2019
Resolution: Alarms and shutdowns have been completed. The MTU on this vessel is not equipped with and overspeed shutdown.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
IMO: Vsl is broadcasting no IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2019
Resolved 22 February 2019
Resolution: vessel operator acknowledged the AIS discrepensy and provided proof from the AIS website.
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2018 Resolved
02106-Hull damage impairing seaworthiness. Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of the vessel is discovered or suspected, the Cognizant OCMI may conduct an internal structure examination in any affected space and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. A Marine Inspector observed a centralized area of advanced corrosion approximately 1/4 inch in diameter. When the area was struck with a hammer, water began to enter the ship. A permanent repair proposal must be submitted, which must include gauging to determine hull periphery thickness.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 April 2019
Resolution: Dry-Dock was completed and all issues were addressed.
Construction/Loadline › Hull › Transverse Frame
Issued 27 April 2018 Resolved
20111-Beams, frames, floor corrosion. Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of the vessel is discovered or suspected, the Cognizant OCMI may conduct an internal structure examination in any affected space and may require the vessel to be dry-docked or taken out of service to assess the extent of the damage, and to effect permanent repairs. A Marine Inspector observed wide-spread wastage in the frames located in the steering room and deterioration of hull plating located in the pump room, collision bulkhead and engine room. A permanent repair proposal must be submitted, which must include gauging to determine hull periphery thickness and to conduct permanent repairs at next dry-dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 April 2019
Resolution: Dry-Dock was completed and all issues were addressed.
Electrical › Electric Generation Source (service) › Generator
Issued 23 March 2018 Resolved
Each vessel that relies on electricity to power the vital systems listed in 119.710, interior lighting, communications, navigation equipment, must be arranged so that the loads can be energized from two sources of electricity. In addition to emergency power sources required under 46CFR112, each self propelled vessel must have at least two electric generation sources. Vessel stbdside generator had a sever malfunction on 03/23/18, on which the connecting rod for piston #1 ruptured the engine block. Properly repair or replace generator with an in-kind and as approved by original plans, and in compliance with 46CFR120.320. (46CFR111.10-03, & 120.310, & 120.320)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: A new generator as in-kind was installed and tested under load.
Engineering › Fuel Oil Service System › Piping
Issued 20 March 2018 Resolved
Correct diesel fuel leak located on all four main diesel engines at the inlet fitting by the cooling plates. It was noted in the vessel logbook that captains have reported the vessel to have fule leaks on several dates without being corrected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2018
Resolution: All four main diesel engines were tested under load, no signs of diesel fuel leaks were detected.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 17 January 2018 Resolved
Correct minor transmission oil leak located at the gasket on the tranmission pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2018
Resolution: New gasket an pump were replaced and corrected by vessel O/O on the spot on 17JAN2018, but deficiency as cleared on 18JAN2018.
Engineering › Lubricating Oil Service System › Gauge
Issued 12 January 2018 Resolved
Lube oil pressure gauge inoperable on the port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 18 January 2018
Resolution: A new pressure gauge was installed and tested, found it operational.
Engineering › Sea-water System (primary cooling) › Pump
Issued 12 December 2017 Resolved
Prove proper operation of main diesel engine number 4 (outer stbdside) including cooling system. 46CFR 119.420.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2017
Resolution: Salt water pump replaced along with a section of raw water piping. The gasket for the oil cooler was changed. Multiple oil Changes conducted. Conducted successful Sea Trials.
Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2017 Resolved
Complete portside generator maintenance of the cooling system. 46CFR420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2017
Resolution: Repaired leaking coolant parts
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 12 December 2017 Resolved
Empty the excessive amount of bilge oily water in central bildge, engine room (about 3 feet high). 46CFR 119.500.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2017
Resolution: Rinsed bilges and removed the oily waste from the bilge.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 12 December 2017 Resolved
Connect the anchor to make it ready for deployment. 46CFR121.300
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2017
Resolution: Reconnected anchor to chain by way of shackle.
Engineering › Lubricating Oil Service System › Piping
Issued 6 December 2017 Resolved
Properly repair and prove operation of #4 MDE (stbd outboard) to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2017
Resolved 12 December 2017
Resolution: Deficiency has been re-issued on a new CG-835.
Construction/Loadline › Structures › Door
Issued 9 October 2017 Resolved
A weathertight door must have means for closing to make it weather tight. Found the following. a) Port and starboard doors for the dek house, main deck, did not have latching devices. b) Second deck portside door leading to the main deck would not closse due to door fraime and hingies being bent. c) Both six (06) dog doors to the engine room would not close and be secured by the dogs. 46 CFR 116.1160
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 20 October 2017
Resolution: All doors were fixed.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 16 June 2017 Resolved
Prove proper operation of fire/bilge alarm panel on bridge.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 12 January 2018
Resolution: Tested multiple bilge alarms to confirm functionality of the panel on the bridge
Accommodation/Occupational Safety › Ventilation › General
Issued 16 June 2017 Resolved
Replace machinery space port side blower guard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 January 2018
Resolution: New guard was is in place over the port blower.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 16 June 2017 Resolved
Provide medical card for Captain.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 12 January 2018
Resolution: Medical card was provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 16 June 2017 Resolved
Provide proper logs for drills, training, life saving and firefighting equipment maintenance.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 17 January 2018
Resolution: Performed Man Overboard, Fire, Security and Abandon ship drills and all were logged in.
Fire Fighting › Fire Pumps › Pressure
Issued 16 June 2017 Resolved
Prove starboard side fire pump provides 50 psi.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 12 January 2018
Resolution: STBD side fire pump provided required 50psi
Engineering › Bilge Water Management System › Not Operational
Issued 8 April 2017 Resolved
Bilge system unable to provide suction during 30 minutes of troubleshooting. Seal air leak from worn gasket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2017
Resolution: The vessel representative had a new gasket installed and was able to draw suction.
Fire Fighting › Fire Pumps › Pressure
Issued 8 April 2017 Resolved
Fire pump gauge does not show pressure. Replace gauge.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 21 April 2017
Resolution: Witnessed the operation of new instaled pressure gauge.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 8 April 2017 Resolved
Exhaust pipe lagging hanging loose from outer starboard main engine, exposing underside of pipe. Re-secure exhaust lagging.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2017
Resolution: The vessel representative re-secured the exhaust lagging.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 8 April 2017 Resolved
Secure power unit controls on inner starboard engine. Observed held in place with rope strings (shoe string size).
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 8 April 2017
Resolution: The vessel representative properly secured the power unit with bolts and nuts as designed.
Stability › Weathertight Integrity › General
Issued 8 April 2017 Resolved
Machinery space hatches cannot be closed weathertight. Prove ability to close hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2017
Resolution: The vessel representative serviced all of the hatches' dogs and was able to make a satisfactory weathertight seal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2016 Resolved
Wiring between both engines lacking metal support at least every 20 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 19 June 2016
Resolution: Metal support was installed IAW with regulation requirements.
Electrical › Electric Supply System (service) › Cable
Issued 19 May 2016 Resolved
Cover exposed wiring on battery cable connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 19 June 2016
Resolution: Wiring was covered and not found to be exposed.
Engineering › Bilge Water Management System › Interface Detector
Issued 19 May 2016 Resolved
High level bilge alarm on #15 activates the fire alarm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 19 June 2016
Resolution: Re-tested the fire & bilge alarms detection panel and was found properly programmed to identify properly and not activating the fire alarm.
Construction/Loadline › Hull › Side Shell
Issued 17 February 2016 Resolved
Crop and renew wasted and holed side shell plating IWO exhaust piping starboard side.
Action required: 705 - Other - as specified
Resolved 22 February 2016
Construction/Loadline › Structures › Cofferdam
Issued 17 February 2016 Resolved
Crop and renew wasted and holed cross flood pipe in center aft void.
Action required: 705 - Other - as specified
Resolved 22 February 2016

Casualty record · 8

23 October 2009Routine · role: Involved in a Marine Casualty · activity 3629698
4 April 2010Routine · role: Involved in a Marine Casualty · activity 3714390
13 September 2010Routine · role: Sighted in Area · activity 3850989
21 February 2012Routine · role: Involved in a Marine Casualty · activity 4251623
9 August 2013Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4693182
13 October 2013Routine · role: Involved in a Marine Casualty · activity 4734590
12 June 2014Routine · role: Involved in a Marine Casualty · activity 4908618
2 October 2014Routine · role: Involved in a Marine Casualty · activity 5061417
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.