Records from 2016 to 2017. Most recent: inspection, 30 November 2017.
Inspection history · 4
30 November 2017
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6311795
6 June 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5898707
27 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5804159
27 January 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5804702
Deck/Cargo › Inert Gas System › IGS Blower
Issued 30 November 2017
Resolved
1830; 74SOLAS(14)II-2/4.5.5.1 FSS CODE 15.2.3.1.2.1; 60ac; PROTECTION OF THE CARGO TANKS SHALL BE ACHIEVED BY A FIX IGS IN ACCORDANCE WITH THE REQUIREMENTS OF THE FSS CODE: SPECIAL CONSIDERATION GIVEN IN ORDER TO PREVENT FLUE GAS LEAKAGES INTO ENCLOSED SPACES. FOUND IGS TO BE LEAKING CO2 INTO IG SPACE.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 December 2017
Resolved 1 December 2017
Resolution: See attached survey report.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 November 2017
Resolved
1899; 46CFR39.2001(j); 40ac; EACH VESSEL VAPOR CONNECTION FLANGE MUST HAVE A PERMANENT STUD PROJECTING OUTWARD LOCATED AT THE TOP OF THE FLANGE FACE. BOTH PORT SIDE VAPOR CONNECTION FLANGES WERE WASTED ENTIRELY REQUIRING PERMANENT REPLACEMENT OF STUDS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 December 2017
Resolved 1 December 2017
Resolution: See attached survey report.
Construction/Loadline › Structures › Door
Issued 30 November 2017
Resolved
1270; ICLL 12.1; 10c; OPENINGS AT ENDS OF ENCLOSED SUPERSTRUCTURES SHALL BE FITTED WITH DOORS WITH MEANS FOR SECURING THE DOORS WEATHERTIGHT WITH CLAMPING DEVICES OR OTHER EQUIVALENT MEANS. STARBOARD SIDE PAINT LOCKER DOOR CLAMPING DEVICE WAS BROKEN AND INOPERABLE MAKING THE OPENING NOT WEATHERTIGHT.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 1 December 2017
Resolution: THE DOOR CLAMPING DEVICE WAS REPAIRED BY VESSEL CREW AND PROPER OPERATION WAS VERIFIED.
Deck/Cargo › Cargo Heating › General
Issued 6 June 2016
Resolved
Cargo Heating steamline, located in engine room storeroom, was found leaking significantly. 74SOLAS(04 cons.)CH.II-1/Reg.33.1
Action required: 705 - Other - as specified
Resolved 6 June 2016
Construction/Loadline › Structures › Deck Plating
Issued 6 June 2016
Resolved
Top step landing on the starboard ladder well between the poop deck and lifeboat deck was found wasted. ICLL Annex I/Reg.25
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 9 June 2016
Resolution: Class Report provided
Construction/Loadline › Hull › Side Shell
Issued 28 January 2016
Resolved
0981: Condition of the ship and its equipment shall be maintained to conform with provisions of the regulations to ensure the ship will remain fit to proceed to sea. Vsl was involved in a marine casualty, collision, with a towing vsl. Damage to port qtr hull plating was sustained. Five frames were observed damaged as well.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 January 2016
Resolved 29 January 2016
Resolution: Received class report attesting to hull damage. No fractures were found, frames found attached to hull. Currently no repairs necessary.