ROLL

ROLL is a 1978 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in August 2026, along with 8 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 20 August 2026.

Built
1978
Last inspected
20 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 August 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

693538
Flag
UNITED STATES
Maury page id
psix-693538

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

20 August 2026 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8469515
14 April 2026 In-Service Inspection · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8349495
13 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090960
12 June 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088658
13 June 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7874317
23 April 2024 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7900345
16 November 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7624406
9 June 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7641363
21 June 2022 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411347
5 November 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161162
21 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161323
2 June 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6965165
5 November 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6849828
9 April 2019 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637764
12 July 2018 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375176
30 November 2017 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307558
13 July 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105924
16 June 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830704
14 April 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829290

Deficiency record · 8

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2022 Resolved
Gauges to indicate lubricating oil pressure must be provided for all propulsion engines. Vessel's oil pressure gauge was inoperable, prove proper operation of oil pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 June 2022
Resolved 21 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2022 Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct inspections, maintenance procedures, and hydrostatic pressure tests as required by NFPA 10. The portable fire extinguisher was manufactured in 2004 and beyond it's replacement date of 12yrs.
Action required: 10 - Deficiency Rectified
Due 21 June 2022
Resolved 21 June 2022
Resolution: Vessel rep replaced extinguisher with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least one inch high. Fuel shutoff valves access not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: Marked the remote fuel shutoff valve location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021 Resolved
Found hole in intake exhaust system. Repair to the satisfaction of the CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: exhaust intake repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 June 2021 Resolved
Install lifelines no more than 12 inches apart. No lifelines at the embarkation point.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: Lifelines installed at the embarkation point.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 June 2021 Resolved
Gauges to indicate cooling water discharge temp and lube oil pressure shall be provided and located in view of the operator station. Both gauges are not on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: Water temp and oil pressure gages installed at the operating station.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 9 April 2019 Resolved
Vessel missing emergency instructions. Provide emergency instructions and post.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 July 2018 Resolved
Provide emergency instruction for vessel.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2018
Resolved 20 July 2018
Resolution: Provided emergency instruction for vessel.

Ownership record