Records from 2004 to 2026. Most recent: inspection, 20 August 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
20 August 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8469515
14 April 2026
In-Service Inspection · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8349495
13 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090960
12 June 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088658
13 June 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7874317
23 April 2024
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7900345
16 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7624406
9 June 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7641363
21 June 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411347
5 November 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161162
21 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161323
2 June 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6965165
5 November 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6849828
9 April 2019
COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637764
12 July 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375176
30 November 2017
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307558
13 July 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105924
16 June 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830704
14 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829290
2 February 2011
Simplified Stability Test
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3937798
2 February 2011
DAPI Audit · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3937805
31 January 2011
Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3936491
29 April 2009
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3416265
5 May 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3184727
17 March 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3166122
14 March 2007
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2888002
24 May 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2628556
12 April 2006
Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2619268
18 May 2005
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2345095
18 May 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2102303
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2022
Resolved
Gauges to indicate lubricating oil pressure must be provided for all propulsion engines. Vessel's oil pressure gauge was inoperable, prove proper operation of oil pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 June 2022
Resolved 21 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2022
Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct inspections, maintenance procedures, and hydrostatic pressure tests as required by NFPA 10. The portable fire extinguisher was manufactured in 2004 and beyond it's replacement date of 12yrs.
Action required: 10 - Deficiency Rectified
Due 21 June 2022
Resolved 21 June 2022
Resolution: Vessel rep replaced extinguisher with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least one inch high. Fuel shutoff valves access not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: Marked the remote fuel shutoff valve location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2021
Resolved
Found hole in intake exhaust system. Repair to the satisfaction of the CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: exhaust intake repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 June 2021
Resolved
Install lifelines no more than 12 inches apart. No lifelines at the embarkation point.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: Lifelines installed at the embarkation point.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 June 2021
Resolved
Gauges to indicate cooling water discharge temp and lube oil pressure shall be provided and located in view of the operator station. Both gauges are not on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2021
Resolution: Water temp and oil pressure gages installed at the operating station.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 9 April 2019
Resolved
Vessel missing emergency instructions. Provide emergency instructions and post.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 April 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 July 2018
Resolved
Provide emergency instruction for vessel.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2018
Resolved 20 July 2018
Resolution: Provided emergency instruction for vessel.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2011
Resolved
Install fixed fire fighting system
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2011
Resolved 24 May 2011
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 10 May 2011
Resolved
Fix lead ballast to prevent shifting.
Action required: 705 - Other - as specified
Due 9 June 2011
Resolved 24 May 2011
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 May 2011
Resolved
Repair cracked seating.
Action required: 705 - Other - as specified
Due 9 June 2011
Resolved 24 May 2011
Stability › Incline Test › General
Issued 31 January 2011
Resolved
Complete a simplified stability test to 185 pounds per person in accordance with the current stability policy prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2011
Resolved 3 May 2011
Resolution: Completed simplified stability proof test.
Stability › Watertight Integrity › General
Issued 29 April 2009
Resolved
Make openings on WX deck IWO aft bench seat watertight.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 7 May 2009
Resolution: The openings on WX deck IWO aft bench seat were fitted with covers making them watertight.
Documentation › Markings/Placards › Garbage Placard
Issued 29 April 2009
Resolved
Post MARPOL V (garbage) placard
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 7 May 2009
Resolution: Placard was posted on board.
Accommodation/Occupational Safety › Ventilation › General
Issued 29 April 2009
Resolved
Repair damaged vent duct on FWD cowl
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 7 May 2009
Resolution: New vent duct was installed.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 24 May 2006
Resolved
Issued: 04 May 06 -- Provide pre-employment testing for all launch operators prior to operators carrying pax.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 30 June 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 24 May 2006
Resolved
Issued: 04 May 06 -- Provide FCC Operator's permit for all vsl operators prior to 03 June 2006 or provide alternative means of communication per launch equivalency letter.
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 22 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2005
Resolved
Replace 3 life jackets.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 May 2005
Resolution: Operator replaced PFD''s
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 May 2005
Resolved
Place child lifejackets in mesh bag
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 May 2005
Resolution: PFD''s placed in bag.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 May 2005
Resolved
Mark jacket ammounts on storage box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 May 2005
Resolution: Jacket locations marked.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 May 2005
Resolved
Replace wing nuts on battery terminals with permanent connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 May 2005
Resolution: Replaced
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 May 2005
Resolved
Re-attach 60' line correctly to lifebuoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 May 2005
Resolution: Line re-attached.