MAURY USCG vessel records Sign in
← All vessels

PEACEMAKER

PEACEMAKER is a 2001 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2004, most recently in January 2026, along with 32 deficiencies.

Records from 2004 to 2026. Most recent: inspection, 12 January 2026.

Built
2001
Last inspected
12 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

ZJL6554
693624
Flag
VIRGIN ISLANDS, BRITISH
—
Maury page id
psix-693624

Inspections, by type

Years with a record 14 calendar years (2004–2026)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it99 - Simplified, Gross Ton
99 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

12 January 2026 Administrative Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8269531
18 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8190463
26 November 2024 Administrative Inspection · ISPS Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8027782
30 May 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7938438
8 December 2023 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7822181
24 May 2023 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7690571
15 November 2022 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7594784
23 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7418422
3 May 2018 Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6403857
20 July 2016 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5946724
4 January 2016 DAPI Audit · ISPS II Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5788480
27 July 2015 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5195928
27 February 2012 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4251912
11 January 2012 ISPS II Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4220356
11 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4226722
20 December 2010 ISPS II Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3913625
19 October 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3872615
11 December 2008 ISPS II Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3377993
22 August 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3305499
1 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3286005
22 October 2007 Initial Certification · ISPS I Exam · ISM Exam · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3084358
18 July 2007 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2999144
14 July 2006 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2715596
1 June 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2102759

Deficiency record · 32

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 November 2022 Resolved
Provide lifesaving equipment servicing report for inflatable buoyant apparatus (IBA). US Passenger count is reduce to 100 persons utilizing the installed IBA (100 person)when any one of the IBA's being serviced. Attending MI's noted that the due date on the IBA's was December 2022.
Action required: 705 - Other - as specified
Due 2 January 2023
Resolved 20 December 2022
Resolution: IBAs serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2022 Resolved
Cable and wiring requirements, wires should be installed with metal supports spaced not more than 610 millimeters (24") apart in such a manner as to avoid chafing and other damage. Attending MI's noted all wire runs were managed with plastic zip ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Supports installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 November 2022 Resolved
Vessel must carry either a first aid kit approved under approval series 160.041 table or with equivalent contents and instructions. Attending CG MI's noted that the first aid kid was incomplete and missing aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Aspirin added to the first aid kit.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 November 2022 Resolved
Emergency Systems Public address system shall be operable. Attending MI's noted that the upper deck starboard speaker was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Public address system repaired. Upper deck speaker replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 November 2022 Resolved
Guards and fencing should be installed around dangerous machinery parts. Guard was missing from the the starboard generator alternator pullies.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Guards installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 November 2022 Resolved
Remote Means of control ventilation, etc and Machinery. Attending MI's noted missing ventilation e stop handles and missing labels for spaces vent closures controlled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Ventilation handles replaced and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 November 2022 Resolved
Provide lifesaving equipment servicing report for inflatable buoyant apparatus (IBA). US Passenger count is reduce to 100 persons utilizing the installed IBA (100 person)when any one of the IBA's being serviced. Attending MI's noted that the due date on the IBA's was December 2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: IBAs serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2022 Resolved
Provide permanently attached mounting bracket for portable fire extinguisher located in starboard engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 1 December 2022
Resolution: Fire extinguisher mount installed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 November 2022 Resolved
Marine inspectors observed (04) four watertight doors that are permanently welded/ blanked off. Upon discussion with owner/operator with attending marine inspectors, Owner stated the doors were blanked off at the direction of the U.S. Coast Guard. Provide historical correspondence to USCG marine inspectors for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Owner provided documentation of prior approval from former resident marine inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 November 2022 Resolved
10 Provide NOAA registration documentation for 406 MHz EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Epirb registered and document provided. Epirb decal affixed to Epirb.
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 July 2016 Resolved
renew the wasted handle on valve in the port side fuel tank space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: replaced valve handle
Electrical › Lighting (service) › Lighting Fixture
Issued 20 July 2016 Resolved
make permanent installation of light fixtue in stbd water tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: light fixture installed propperly
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 July 2016 Resolved
install cover on junction box in stbd water tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: Cover installed
Communications › Radio Communications › EPIRB
Issued 4 January 2016 Resolved
PROVIDE PRINTOUT OF EPIRB SHOWING THE UNIT IDENTIFICATION NUMBER (UIN) AND LABEL THE EPIRB WITH THE SAME.
Condition: Improper/Lack of Maintenance
Due 31 January 2016
Resolved 22 July 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 27 July 2015 Resolved
Make permanent repairs, and prove proper operation of, stbd Engine Room Emergency Escape deck scuttle located in Luggage Space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2015
Resolved 4 January 2016
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 27 July 2015 Resolved
Make permanent repairs, or replace, port and stbd IBA mounting cradle to prevent damage to the container.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2015
Resolved 4 January 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 July 2015 Resolved
Make permanent repairs to all fractured welds found at exhaust piping penetration, aft side of port and stbd engine room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2015
Resolved 4 January 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 July 2015 Resolved
Renew both exhaust pipe flexible hoses found stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2015
Resolved 4 January 2016
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 11 January 2012 Resolved
Provide and submit a Search and Rescue Cooperative Plan (SAR CO-OP Plan) to USCG Sector San Juan for review and approval.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 14 March 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 January 2012 Resolved
Prior to carrying passengers in U.S. waters, make permanent repairs to portable fire extinguisher (PFE) mounting bracket for PFE located across from main deck passenger salon concession stand and aft door.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 29 November 2012
Fire Fighting › Ventilation Systems › Operating Controls
Issued 9 January 2012 Resolved
Prior to carrying passengers in U.S. waters, make permanent repairs to starboard ventilation emergency air shut-off.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 29 November 2012
Documentation › Certificates/Documents › FCC SSL
Issued 9 January 2012 Resolved
Prior to carrying passengers in U.S. waters, provide valid Ship Radio Station Authorization Certificate.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 14 March 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 December 2010 Resolved
Provide a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions, as per 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 9 January 2012
Documentation › Certificates/Documents › Exemption Certificate (SOLAS)
Issued 11 December 2008 Resolved
PRIOR TO CARRYING PASSENGERS IN USVI WATERS, PROVIDE VALID AIS AND VDR EXEMPTION LETTER FROM FLAG STATE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2008
Resolved 11 December 2008
Engineering › Bilge Water Management System › Not Operational
Issued 22 August 2008 Resolved
PROVE PROPER OPERATION OF ALL HIGH BILGE WATER ALARMS AT FIRST U.S. PORT CALL.
Action required: 705 - Other - as specified
Due 12 December 2008
Resolved 11 December 2008
Engineering › Fuel Oil Service System › Filter
Issued 22 August 2008 Resolved
PROVIDE AND INSTALL CG APPROVED METAL HEAT DEFLECTOR SHIELD FOR RACOR FUEL FILTER/SEPERATOR UNIT LOCATED WITHIN PORT AND STARBOARD FUEL TANK COMPARTMENT AT FIRST U.S. PORT CALL.
Action required: 705 - Other - as specified
Due 12 December 2008
Resolved 11 December 2008
Stability › Unintentional Flooding › General
Issued 22 August 2008 Resolved
PROVIDE AND INSTALL ONE ADDITIONAL STEEL CLAMP FOR PORT AND STARBOARD MAIN ENGINE SEA SUCTION HOSE AT FIRST U.S. PORT CALL.
Action required: 705 - Other - as specified
Due 12 December 2008
Resolved 11 December 2008
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 22 October 2007 Resolved
PROVIDE PROOF OF SAFETY MANAGEMENT SYSTEM (SMS) ANNUAL AUDITS.
Action required: 705 - Other - as specified
Due 23 October 2007
Resolved 12 December 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 October 2007 Resolved
PROVIDE AUTOMATIC SHUTDOWN FOR PROPULSION ENGINES, GENERATORS AND VENTILATION BLOWERS UPON CO2 ACTIVATION.
Action required: 705 - Other - as specified
Due 23 October 2007
Resolved 12 December 2007
Fire Fighting › Fire Main › Pressure
Issued 22 October 2007 Resolved
PROVIDE AND INSTALL 0-100 PSI GAUGE FOR STARBOARD FIRE MAIN, AFT MAIN DECK.
Due 23 October 2007
Resolved 20 November 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 October 2007 Resolved
SUBMIT PLANS AND DETAILS FOR BOLTED-IN TRANSVERSE BULKHEAD PLATES TO USCG MARINE SAFETY CENTER FOR REVIEW/APPROVAL.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 16 July 2010
Resolution: As per MSC Letter H1-1001869 dated 16JUL10.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 22 October 2007 Resolved
AMEND COMPANY'S SAFETY MANAGEMENT SYSTEM TO INCLUDE COMPANY POLICY FOR MEETING THE TWO (2) HOUR RULE AND INCORPORATE ASSOCIATED FORM(S).
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 12 December 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.