Behind this panel: 11 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
12 January 2026
Administrative Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8269531
18 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8190463
26 November 2024
Administrative Inspection · ISPS Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8027782
30 May 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7938438
8 December 2023
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7822181
24 May 2023
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7690571
15 November 2022
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7594784
23 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7418422
3 May 2018
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6403857
20 July 2016
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5946724
4 January 2016
DAPI Audit · ISPS II Exam · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5788480
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 November 2022
Resolved
Provide lifesaving equipment servicing report for inflatable buoyant apparatus (IBA). US Passenger count is reduce to 100 persons utilizing the installed IBA (100 person)when any one of the IBA's being serviced. Attending MI's noted that the due date on the IBA's was December 2022.
Action required: 705 - Other - as specified
Due 2 January 2023
Resolved 20 December 2022
Resolution: IBAs serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2022
Resolved
Cable and wiring requirements, wires should be installed with metal supports spaced not more than 610 millimeters (24") apart in such a manner as to avoid chafing and other damage. Attending MI's noted all wire runs were managed with plastic zip ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Supports installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 November 2022
Resolved
Vessel must carry either a first aid kit approved under approval series 160.041 table or with equivalent contents and instructions. Attending CG MI's noted that the first aid kid was incomplete and missing aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Aspirin added to the first aid kit.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 November 2022
Resolved
Emergency Systems Public address system shall be operable. Attending MI's noted that the upper deck starboard speaker was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Public address system repaired. Upper deck speaker replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 November 2022
Resolved
Guards and fencing should be installed around dangerous machinery parts. Guard was missing from the the starboard generator alternator pullies.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Guards installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 November 2022
Resolved
Remote Means of control ventilation, etc and Machinery. Attending MI's noted missing ventilation e stop handles and missing labels for spaces vent closures controlled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Ventilation handles replaced and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 November 2022
Resolved
Provide lifesaving equipment servicing report for inflatable buoyant apparatus (IBA). US Passenger count is reduce to 100 persons utilizing the installed IBA (100 person)when any one of the IBA's being serviced. Attending MI's noted that the due date on the IBA's was December 2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: IBAs serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2022
Resolved
Provide permanently attached mounting bracket for portable fire extinguisher located in starboard engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 1 December 2022
Resolution: Fire extinguisher mount installed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 November 2022
Resolved
Marine inspectors observed (04) four watertight doors that are permanently welded/ blanked off. Upon discussion with owner/operator with attending marine inspectors, Owner stated the doors were blanked off at the direction of the U.S. Coast Guard. Provide historical correspondence to USCG marine inspectors for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Owner provided documentation of prior approval from former resident marine inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 November 2022
Resolved
10 Provide NOAA registration documentation for 406 MHz EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2023
Resolved 20 December 2022
Resolution: Epirb registered and document provided. Epirb decal affixed to Epirb.
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 July 2016
Resolved
renew the wasted handle on valve in the port side fuel tank space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: replaced valve handle
Electrical › Lighting (service) › Lighting Fixture
Issued 20 July 2016
Resolved
make permanent installation of light fixtue in stbd water tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: light fixture installed propperly
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 July 2016
Resolved
install cover on junction box in stbd water tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: Cover installed
Communications › Radio Communications › EPIRB
Issued 4 January 2016
Resolved
PROVIDE PRINTOUT OF EPIRB SHOWING THE UNIT IDENTIFICATION NUMBER (UIN) AND LABEL THE EPIRB WITH THE SAME.
Condition: Improper/Lack of Maintenance
Due 31 January 2016
Resolved 22 July 2016