Records from 2004 to 2023. Most recent: inspection, 6 July 2023.
Inspection history · 36
6 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7734617
10 February 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7632158
6 September 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7553113
29 August 2022
MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7546408
17 May 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7452976
15 September 2021
PSC B · COC-CHEM Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7312715
25 May 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6959815
26 January 2019
Ballast Water Examination · COE-Administrative · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6612655
25 January 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6615190
22 January 2018
Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6341718
17 January 2017
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6070652
18 October 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6024653
26 February 2016
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5822443
9 February 2016
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5809233
3 February 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5809083
16 October 2015
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5744225
11 June 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4886367
18 June 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4348143
5 June 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4335069
23 February 2012
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4246838
5 February 2011
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3939742
15 January 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3925187
25 March 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3702742
1 February 2010
MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-CHEM Annual · MARPOL Annex VI Survey · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3671297
25 January 2010
NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3669332
28 December 2009
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3655823
22 December 2009
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3653989
20 December 2009
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3653186
21 April 2009
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3457314
3 February 2009
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3411475
25 February 2008
Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3153095
20 January 2006
MARPOL Annex I Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2569934
17 January 2006
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2567824
3 January 2006
MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2559514
26 November 2004
ISPS II Exam · COC-TVE Annual
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2248609
26 November 2004
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2276712
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 January 2018
Resolved
0520- electrical lighting installations shall be such as to minimize the risk of fire and explosion from flammable products. 90% of deck lighting are not gastight and show either condensation and/or debris inside the casing. forward port light is cracked. 74SOLAS(14)VII/10.1 IBC Code 10.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2018
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 22 January 2018
Resolved
2515- the company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company...the company should ensure that appropriate corrective action is taken. Ship ordered lighting fixtures on 12/27/2017 and intended to be delivered on 01/16/2018 (ref form no. 3837-0026). Parts have not been delivered as of this date. 74SOLAS(14)IX/3.1 ISM Code 10.2.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2018
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement.
Construction/Loadline › Markings › Load Line Mark
Issued 17 January 2017
Resolved
The rings, lines and letters shall be painted in white or yellow on a dark ground or black on a light ground. The portside loadline is not visible. ICLL 1966 Annex I, Reg 8. 10c
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Def cleared on site, crew repainted loadline.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 23 February 2012
Resolved
1099- Vessel's visual signal for cargo tanks overfill alarm on deck does not operate. The vessel's audible and visual overfill alarm must be heard and seen where cargo transfer is controlled and in the cargo deck area. Vessel is restricted to not load cargo tanks past 95% 46CFR 39.20-7(d)(2)
Action required: 705 - Other - as specified
Due 8 March 2012
Resolved 8 March 2012
Resolution: Received repair orders and photographs from Captain of proper operation of overfill and high level lights.
Lifesaving › Launching Appliances › Release Mechanism
Issued 1 February 2010
Resolved
0610- Lifeboats- The remote control releasing line did not properly unspool from winch drum. Excessive tension was placed on fixed davit arm and mid-point pulley support. Lifeboat cannot be launched from inside the boat as designed. SOLAS 74(a) 2004 cons. III/20
Action required: 705 - Other - as specified
Due 8 February 2010
Resolved 5 February 2010
Resolution: Received, reviewed and approved class report from Lloyd''s Register clearing deficiency. Class report stated: pulley support frames, remote control pulley''s guide bar and aft/outboard A-frame repaired. Launching appliances tested and found in good order.
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 December 2009
Resolved
X-Band Radar onboard is malfunctioning due to inoperative screen connection to radio scanner.
Action required: 705 - Other - as specified
Due 6 January 2010
Resolved 31 December 2009
Resolution: Attended vessel and cleared deficiency.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 February 2009
Resolved
Vessel is required to have 04 chemical safety suits onboard the vessel. Vessel currently has 01 chemical suit onboard and 03 have been on order, since 31 OCT 08. Provide 03 additional chemical suits for a total of 04 suits onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2009
Resolved 21 April 2009
Resolution: Sector San Juan received confirmation via Vsl agent [name withheld] of Inchcape Shipping Services showing proof of Vsl compliance
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 January 2006
Resolved
Control panel for Oily Water Separator not in proper working order.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2006
Resolution: Rep. from SIMTECH LTD. was onboard to repair Oily Water Separator, re-programmed control panel, conducted satisfactory operational test of Oily Water Separator (witnessed by Coast Guard inspectors). Copy of service report obtained by Coast Guard.