Records from 1996 to 2010. Most recent: inspection, 10 August 2010.
Inspection history · 14
10 August 2010
Administration
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3820424
23 April 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 768873
12 April 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 178768
12 April 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 210025
28 October 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 726687
26 October 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 422188
22 October 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 421836
23 August 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 138032
17 February 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 723550
2 October 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 66583
6 August 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 443270
7 June 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 676294
6 June 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 676295
8 May 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 64991
Lifesaving
Issued 22 October 1998
No resolution recorded
Missing Main deck stanchion on starboard side.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Engineering
Issued 22 October 1998
No resolution recorded
Many of the vessel's fuel/oil vents did not have flame screens installed and some were torn.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Lifesaving
Issued 22 October 1998
No resolution recorded
Mates room has evidence of smoking in bed. Their was burn holes on the blanket and the ash tray was full next to the bed.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Navigation
Issued 22 October 1998
No resolution recorded
33 U.S.C. 2023(a) (RULE 23) Navigational lights mast, sidelights, stern, tow lights have household bulbs installed.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Documentation
Issued 22 October 1998
No resolution recorded
46 C.F.R. 67.313 Marine documentation on board expired on Aug 98.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Documentation
Issued 22 October 1998
No resolution recorded
33 C.F.R. 164.72 No Local Notice to Mariners on board.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Documentation
Issued 22 October 1998
No resolution recorded
33 C.F.R. 164.72 Vessel does not have a Coast Guard lights lists on board.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 22 October 1998
No resolution recorded
33 C.F.R. 159.7 MSD had no evidence of chemical use.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Navigation
Issued 22 October 1998
No resolution recorded
Hydraulic leaks on the steering system
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Engineering
Issued 22 October 1998
No resolution recorded
Excessive amount of slop oil in the bilges.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Fire Fighting
Issued 22 October 1998
No resolution recorded
46 C.F.R. 25.30-20(b)(1) All portable Fire fighting equipment o/b expired on June 1996.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Fire Fighting
Issued 22 October 1998
No resolution recorded
46 C.F.R. 25.30-20(b)(2) Fixed fire extinguishing system in engine room empty.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Navigation
Issued 22 October 1998
No resolution recorded
Guards missing on electrical outlet boxes, missing guards around moving machinery in the engine room, guards missing around light socket.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded
Electrical
Issued 22 October 1998
No resolution recorded
Exposed wiring throughout the vessel.
Condition: Unknown
Due 1 December 1998 — due date passed with no resolution recorded