Records from 2004 to 2019. Most recent: inspection, 8 October 2019.
Inspection history · 21
8 October 2019
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6826486
27 December 2018
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6603195
14 June 2018
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6443957
1 February 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6347855
6 October 2017
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6282140
5 April 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6362444
4 April 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6117671
4 April 2017
COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6117681
28 March 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6113349
11 June 2016
Ballast Water Examination · Deficiency Check · COC-TVE Renew · ISPS II Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5902086
21 December 2011
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4209730
14 December 2010
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3910304
27 November 2010
COC-TVE Renew · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3893846
25 January 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3669294
15 January 2010
MARPOL Annex I Examination · ISPS II Exam · COC-TVE Annual · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3655256
23 November 2008
PII Safety Exam · COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3367828
20 February 2008
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3142078
4 January 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2850263
24 June 2004
NPV Safety Exam · COC-TVE Renew · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2109511
23 June 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2111233
21 June 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2106338
Fire Fighting › Fire Main › Valves
Issued 11 June 2016
Resolved
0740-Pumps-Fire Main supply isolation valve from E/R labeled WD-64 is not operational. Thus limiting the output of the fire fighting apparatus. SMS indicates monthly checks conducted 04 May 2016. Testing of fire monitors using pumps 1 & 2 independently provided insufficient deck coverage. SOLAS (04 Con) II-2 / 10.2.1.4 17A,C
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2016
Resolved 14 June 2016
Resolution: RECEIVED CLASS REPORT ATTESTING TO SATISFACTORY REPAIRS. DEFICIENCY CLEARED.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 27 November 2010
Resolved
2199- MARPOL Operational Def- The oil discharge monitoring and control system shall be designed, installed in compliance with the guidelines and specifications for oil discharge monitoring and control systems for oil tankers. The ODME was operationally tested, it reported back a fault in its line communication system with its remote sensors. MARPOL 73/78 Annex I/Reg31
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 21 December 2011
Resolution: Vessel provided class report attesting to the repair of the ODME. PSCO tested equipment and test was satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 27 November 2010
Resolved
1400- Propulsion Auxiliary- The machinery, boilers, and others pressure vessels associated piping systems and fittings shall be designed and constructed of adequate service. The #1 SSDG jacket feed water line has a non class approved temporary soft patch installed. SOLAS 74am II/I-26
Action required: 705 - Other - as specified
Due 4 December 2010
Resolved 14 December 2010
Resolution: Received class report from American Bureau of Shipping satisfying requirement.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 25 January 2010
Resolved
Vessel Missing Anchor. 33 CFR 164.11(o)
Due 16 April 2010
Resolved 26 January 2010
Resolution: Received Class report requiring vessel to replace anchor by 16APR10.