GULF BREEZE
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named GULF BREEZE
GULF BREEZE is a 2004 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2004, most recently in September 2025, along with 70 deficiencies and 1 casualty investigation in 2010.
Records from 2004 to 2025. Most recent: inspection, 3 September 2025.
- Built
- 2004
- Last inspected
- 3 September 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 70 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2010
Identity
1158541
WDI3017
694669
Flag
UNITED STATES
367684130
Maury page id
psix-694669
Inspections, by type
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.8 ft × 19.0 ft × 10.0 ft
Registered tonnagegross 82 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS · WETUMPKA, AL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Simplified, Gross Ton
65 - Simplified, Net Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI3017MMSI 367684130 · active · compulsorily equipped · granted 2 July 2025, expires 16 July 2035
WDB9757MMSI 366982150 · expired · compulsorily equipped · granted 7 October 2004, cancelled 13 December 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 33
3 September 2025
Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8254469
5 May 2025
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8121482
9 January 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8057171
29 April 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7903885
23 October 2023
Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7813061
19 July 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7746561
8 May 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7683478
3 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7680420
11 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7620539
11 October 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7575129
9 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7447614
26 October 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7340090
27 April 2021
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7183027
12 January 2021
Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7122979
14 May 2020
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6893288
16 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6835974
7 February 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620278
8 January 2019
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6609063
23 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570695
15 May 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6411907
7 February 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6081868
17 January 2017
Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6070510
19 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5880815
10 June 2014
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4890483
24 January 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4228722
20 January 2011
Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3930714
11 February 2010
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677987
7 January 2009
Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3387566
12 March 2008
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3158987
3 April 2007
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2900593
23 January 2007
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2898446
14 April 2005
Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2334811
3 August 2004
Internal Structural Exam · Hull Examination · Initial Certification · Construction Oversight · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2241959
Deficiency record · 70
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2024
Resolved
Inspect steering. Stbd rudder post top bearing was worn.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2023
Resolved
Each ring buoy on a vessel must: if on a vessel on an oceans or coastwise route, be orange in color. Coast Guard inspectors witnessed the ring buoy on the aft deck with discoloration. Repair or replace this life-saving device to be orange in color.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 3 May 2023
Resolved
The construction and arrangement of a vessel must allow for the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Coast Guard inspector witnessed the access/exit ladder located in the forepeak to be in substandard condition. Conduct the proper repair or replace the ladder to ensure its safety and proper usage.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 January 2021
Resolved
Repair and/or replace Main Cabin doors, frames, and securing devices to make doors weathertight.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 January 2021
Resolved
Add Fender washers as neded to railing mounts/bolts.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 January 2021
Resolved
Replace anchor line thimble.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2021
Resolved
Repair/replace 04 electrical sockets in the Main Cabin.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 January 2021
Resolved
Repair/replace strainer in Bilge system.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 12 January 2021
Resolved
Crew berthing does not have a bulb/guard. Order, obtain, and install to make operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2021
Resolved
Secure junction box to ensure proper enclosure.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019
Resolved
Vessel was not made available to conduct in-service inspection. Vessel is prohibited from carrying passengers overnight until vessel completes in-service inspection to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 January 2017
Resolved
Replace port and starboard cutlass bearing
Engineering › Steering Gear System › Rudder
Issued 13 June 2014
Resolved
Vessel is required to visual inspect steering gear compartment, rudder assembly, and bilge alarm prior to getting underway and every hour after leaving dock. Visual inspection shall be logged in official log book and any abnormal condition or leaking immediately reported to MSD Panama City.
Engineering › Steering Gear System › Rudder
Issued 12 June 2014
Resolved
Repair port rudder foot leak and satisfactory conduct underway vessel operation.
Engineering › Bilge Water Management System › Pump
Issued 10 June 2014
Resolved
Repair / Replace fwd bilge pump
Engineering › Bilge Water Management System › Hose
Issued 10 June 2014
Resolved
Replace / repair aft bilge pump discharge hose
Engineering › Steering Gear System › Rudder
Issued 10 June 2014
Resolved
Troubleshoot stbd rudder foot leak at aft base and provide repair proposal.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 June 2014
Resolved
Provide fixed system service report attesting to the overpressure condition.
Lifesaving › Lifefloat › Float-free Link
Issued 10 June 2014
Resolved
Replace lifefloat weak link with proper size.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 10 June 2014
Resolved
Demonstrate proper operation of stbd engine.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 June 2014
Resolved
Post COI and stability letter.
Communications › Radio Communications › EPIRB
Issued 11 February 2010
Resolved
Replace expired EPIRB battery as required by manufacturer's expiration date.
Lifesaving › Buoyant Apparatus › Painter
Issued 11 February 2010
Resolved
Renew the painter line and pendant lines to the top lifefloat and the painter line to the bottom life float as required by 46CFR180.175(f) to the satisfaction of the attending marine inspector.
Engineering › Steering Gear System › Linkage
Issued 11 February 2010
Resolved
Tighten the connection from the port tiller arm to the jockey bar to the satisfaction of the attending marine inspector.
Engineering › Steering Gear System › Rudder Stock
Issued 11 February 2010
Resolved
Tighten face plate underneath the tillar arm connection on the port and starboard tillar to the satisfaction of the attending marine inspector.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 February 2010
Resolved
Free up dogs on both the lazarette and fuel tank compartment hatch covers as required by 46CFR176.800 to the satisfaction of the attending marine inspector.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 11 February 2010
Resolved
Tighten the connection to the overboard valve on the vent line on top of the fuel tank and double hose clamp the connection to the overboard valve on the vent line as required by 46CFR182.720.
Engineering › Fuel Oil Service System › Piping
Issued 11 February 2010
Resolved
Renew bonding straps on both port and starboard fuel fill lines as required by 46 CFR 182.445(g).
Engineering › Fuel Oil Service System › Tank
Issued 11 February 2010
Resolved
Remove leaking drain line valve on the diesel fuel tank and prove tightness to the satisfaction of the attending marine inspector.
Engineering › Bilge Water Management System › Pump
Issued 11 February 2010
Resolved
Permanently mount all loose electric bilge pumps as required by 46CFR182.520(e) to the satisfaction of the attending marine inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 February 2010
Resolved
Renew diffuser on tube lighting above both port and starboard engines as required by 46CFR183.410(a).
Electrical › Lighting (service) › Lighting Fixture
Issued 11 February 2010
Resolved
Renew or remove lighting fixture mounted on the starboard aft engine room bulkhead as required by 46CFR183.410(a) to the satisfaction of the attending marine inspector.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 11 February 2010
Resolved
Remove debris and excessive amounts of oil in fuel tank compartment bilge and aft accommodations bilge as required by 46CFR183.350.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2010
Resolved
Clean up and tighten connections to all loose battery terminals and secure properly to protect against shifting with the roll and pitch of the vessel as required by 46CFR183.350.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 February 2010
Resolved
Tighten the protective guard over the flywheel on the generator as required by 46CFR176.830(b).
Engineering › Fuel Oil Service System › Hose
Issued 11 February 2010
Resolved
Remove fuel under generator and repair the leak as required by 46CFR179.360(b)(2) to the satisfaction of the attending marine inspector.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 February 2010
Resolved
Install captive device to all deck hatch covers as required by 46 CFR 179.360(b)(2).
Stability › Watertight Integrity › Coaming
Issued 11 February 2010
Resolved
Repair and maintain watertight coaming of a height of at least 6 inches in way of the aft weather tight door as required by 46 CFR 179.360(d)(1).
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 February 2010
Resolved
Re-label child life preservers locker to reflect "6" instead of 5.
Engineering › Bilge Water Management System › Pump
Issued 11 February 2010
Resolved
Re splice wiring for electric bilge pump in lazarette.
Lifesaving › Lifefloat › Markings
Issued 11 February 2010
Resolved
Properly mark each life float with vessel name and capacity.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 February 2010
Resolved
Renew holed hydraulic flexible non-metalic hose located in lazarette with a hose that meets SAE standard J-1942.
Lifesaving › Lifefloat › Netting
Issued 11 February 2010
Resolved
Renew deteriorated support cordage for life float netting.
Navigation › Piloting/Steering › Notices to Navigation
Issued 11 February 2010
Resolved
Update all nautical publications and charts to the latest notice to mariners.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 February 2010
Resolved
Provide Rules to the Road booklet.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2010
Resolved
Service starboard battery bank to ensure batteries are fully charged.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2010
Resolved
Install proper connections for electrical wires feeding two flotec pumps in engine room.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 February 2010
Resolved
Renew lanyard clip to ring buoy water light.
Stability › Weathertight Integrity › General
Issued 11 February 2010
Resolved
Repair and renew damaged door latch on starboard side.
Engineering › Steering Gear System › Ram
Issued 7 January 2009
Resolved
Replace thru bolt for port hydraulic ram, and double nut.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 January 2009
Resolved
Grind and fare gelcoat located in lazerette on the port side.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 January 2009
Resolved
Replace conduit box, and reconnect wires located in the tank room on the aft bulkhead.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 7 January 2009
Resolved
Remove excess fuel in tank room and remove debris in bunk room.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 January 2009
Resolved
Replace lanyard for forpeak hatch.
Documentation › Markings/Placards › Capacity Marking
Issued 7 January 2009
Resolved
Provide placard for maximum number of passengers per stability letter.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 7 January 2009
Resolved
Remount tank space bilge pump, and lazarette bilge pump.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 3 April 2007
Resolved
Service Fixed Fire Detection System and demonstrate proper operation (46 CFR 181.400)
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 April 2007
Resolved
Provide safety chains on 01 deck rail, forward of pilot house. (46 CFR 177.900)
Lifesaving › Lifefloat › Serviceable
Issued 3 April 2007
Resolved
Provide suitable spacers for life floats that are stowed in tiers forward of pilot house as required by 46 CFR 180.137.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 3 April 2007
Resolved
Relocate B II portable fire extinguisher inside machinery space to a location just outside machinery space entrance as required by 46 CFR 181.500
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 October 2005
Resolved
Replace breakers for bunk lights and cabin to match approved plans as required by 46CFR183.200
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 October 2005
Resolved
2. Replace main breaker in distribution panel to match plans as required by 46CFR183.200
Electrical › Electric Generation Source (service) › Generator
Issued 21 October 2005
Resolved
3. De-rate generator to 80 percent of full load as required by 46CFR183.320
Stability › Watertight Integrity › General
Issued 21 October 2005
Resolved
4. Make bulkhead between lazarette and fuel tank space watertight (pipe run outboard stbd side not watertight) in accordance with 46CFR179.320
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 21 October 2005
Resolved
6. Repair oil leak on port engine as required by 46CFR182.100
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 October 2005
Resolved
7. Mount shaft cooling hose as required by 46CFR182.720
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 21 October 2005
Resolved
8. Provide proof that bridge glass meets 46CFR177.1010
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 November 2004
Resolved
5. Repair leak in exhaust cooling pipe (@threaded fitting) port engine as required by 46CFR182.430
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 16 November 2004
Resolved
9. Provide proof that mattresses located in accommodation spaces meet IMO A.688 or 16CFR part 1632
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 November 2004
Resolved
10. Change amount of child life jackets from 5 to 6 on storage container. IAW 46CFR185.604
Casualty record · 1
23 July 2010Routine · role: Involved in a Marine Casualty · activity 3902893
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.