Records from 2010 to 2025. Most recent: inspection, 29 September 2025.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 16.0 ft × 7.0 ft
Registered tonnagegross 31 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
29 September 2025
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8230340
30 September 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8013803
30 May 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7923222
2 October 2023
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7802229
17 July 2023
Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7741586
6 October 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7577139
21 July 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7512517
5 April 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7424739
18 August 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7290020
5 August 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7024964
25 September 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6820407
15 July 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6750364
1 May 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6674013
26 June 2018
Initial Certification · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6456332
12 March 2018
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370699
3 October 2014
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4998450
22 April 2014
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4847182
1 August 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4409635
10 February 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3946477
17 February 2010
Administration
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3682247
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 29 September 2025
Resolved
Fixed fire-extinguishing system means: (1) A carbon dioxide system that meets the requirements of... 46 CFR 78.47-11. Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems...must be conspicuously marked as follows:
(a) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”
(b)Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” Entrance to engine room must be labeled.
46 CFR 136.110
46 CFR 78.47-11(a) & (b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 5 December 2025
Resolution: Received satisfactory photos of CO2 warning labels.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 September 2025
Resolved
Marine Employer must submit an MIS report by March 15th every year, and have records to prove submittal. A consortium or other employer representative may submit data for a marine employer. Reports may contain data for more than one marine employer. Each report, however, must list the marine employers included in the report. Company could not provide a copy of the latest MIS report.
46 CFR 16.500
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 31 October 2025
Resolution: Received satisfactory copy of MIS report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 September 2025
Resolved
Extension cords must not be used as a permanent connection to a source of electrical power. Power strip in accommodation space must be removed.
46 CFR 143.575(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 31 October 2025
Resolution: Operator submitted satisfactory photo showing removal of power strip.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 30 September 2024
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States:(c) Every towing vessel of 7.8 meters (26 feet) or over in length, measured from end to end over the deck excluding sheer. The vessel's FCC Bridge-to-Bridge Act Safety Certificate is expired. Submit a valid FCC Bridge-to-Bridge Act Safety Certificate to the CG Marine Inspector.
47CFR80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 October 2024
Resolution: The vessel's FCC Bridge-to-Bridge Act Safety Certificate is no longer expired. Submitted a valid FCC Bridge-to-Bridge Act Safety Certificate to the CG Marine Inspector. Issued on 05OCT2024, certificate will remain in force until 05OCT2029.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 October 2023
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Attending Marine Inspector identified an accumulation of oily mixture in the bilges. Properly remove oily mixture to the satisfaction of attending marine inspector from this office prior to operating.
46 CFR 142.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 October 2023
Resolution: The oily water substance was removed from the bilge. The condition of the bilge was clean and dry. The bilge pump was renewed and the condition of the bilge pump overboard discharge hose was clean. OP tested new bilge pump, verified bilge alarm. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 July 2023
Resolved
Fire-detection systems must be inspected or tested at least once every 12 months and must be recorded in the TVR or official logbook.
Fire detection system has not been tested in the last 12 months.
46 CFR 142.240
Action required: 60 - Rectify deficiencies prior to movement
Due 17 July 2023
Resolved 20 July 2023
Resolution: Received objective evidence from the O/O that fire detection system was inspected and tested satisfactory.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 17 July 2023
Resolved
Alarm setpoints for the propulsion engines and generator must be tested IAW MFR instructions twice in 5 years, with no more than 3 years elapsing since last test.
No records for alarm setpoint testing for propulsion engines were available for over the past 3 years.
46 CFR 143.245
Action required: 60 - Rectify deficiencies prior to movement
Due 17 July 2023
Resolved 19 July 2023
Resolution: Received objective evidence from the O/O that alarm set points for the propulsion engines and generator was tested satisfactory IAW MFR instructions.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 17 July 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attn.
Missing visual and audible alarms at operating station for low hydraulic steering fluid level, and generator low lube oil pressure.
46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 17 August 2023
Resolution: Verified installation and witnessed satisfactory operational testing of visual and audible alarms at operating station for low hydraulic steering fluid level, and generator low lube oil pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 July 2023
Resolved
The following systems must be equipped with gauges at the machinery location; Aux Generator lube oil, RPM, cooling water temp, and steering hydraulic pressure.
Missing the following gauges at the machinery location: generator lube oil pressure, generator jacket water temperature, generator RPM, and steering fluid pressure.
46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 17 August 2023
Resolution: Verified installation and witnessed satisfactory operation of gauges at the machinery location: generator lube oil pressure, generator jacket water temperature, generator RPM, and steering fluid pressure.