MAURY USCG vessel records
← All vessels

RELENTLESS

RELENTLESS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in April 2026, along with 11 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 27 April 2026.

Built
2004
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
…with no type recorded4
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI3686
695011
Flag
UNITED STATES
Maury page id
psix-695011

Documentation record

Registered dimensions (L × B × D)64.8 ft × 18.8 ft × 10.0 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS INC · WETUMPKA, AL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 26

27 April 2026 Vessel Attendance · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8356478
19 December 2025 Internal Structural Exam · Administrative Inspection · Vessel Attendance · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285584
3 September 2025 Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226495
2 June 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8150884
4 February 2025 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8116475
24 April 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7901301
13 March 2024 Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7878907
30 January 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7852548
13 September 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7790924
10 April 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7667082
4 April 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7424747
27 January 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7386483
19 July 2021 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7257876
8 March 2021 Type not recorded
No type recorded · USCGC NORTHLAND (WMEC 904) · Activity 7152526
13 October 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7075905
30 January 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6900263
26 September 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6823002
13 August 2019 DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6783267
28 March 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6651788
8 September 2018 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6536215
30 August 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6526764
23 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340443
14 September 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6265849
2 June 2017 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6164180
7 July 2016 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5929955
21 January 2016 Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5800654

Deficiency record · 11

08 - Alarms › N/A - No Subsystem › General alarm
Issued 11 May 2026 No resolution recorded
Vessel's installed watchman device did not operate as required. Alarm can be silenced from operation station and accommodation space device timer cannot be reset when watch stander presses button. Vessel is prohibited from carrying overnight passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 11 May 2026 No resolution recorded
Vessel must have a means to recover a person from the water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2025 Resolved
Vessel's installed watchman device does not operate as intended. The alarm and interval set point can both be silenced/reset from the operating station. Vessel is prohibited from carrying more than 06 overnight passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2026
Resolution: 2026 Annual Inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2024 Resolved
Generator fuel filter missing metallic heat shield.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 June 2025
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 April 2024 Resolved
Hatch to lazarette needs to made watertight. Hatch was missing gasket and was not secured to deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 June 2025
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 24 April 2024 Resolved
Vessel Master did not have medical certificate onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 24 April 2024 Resolved
Watchman device in main accommodation space was inoperable. Vessel restricted to no more that 6 overnight passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 May 2024
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 24 April 2024 Resolved
Vessel did not have a Drug and Alcohol policy onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 1 May 2024
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 April 2023 Resolved
Test high water alarm. Engine compartment high water alarm float was blocked by grounding strap.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 13 September 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2023 Resolved
Test emergency fuel valves. Emergency fuel valves did not fully close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 13 September 2023
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2019 Resolved
Vessel required to have waterlight attached to the life float by a 18" line 3/8" wide that is resistant to ultraviolet deterioration. 46 CFR 180.175 (f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 26 September 2019
Resolution: Vessel crew provided and installed a line of correct length and width to the life float.

Ownership record