RELENTLESS

RELENTLESS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2003, most recently in April 2026, along with 42 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records from 2003 to 2026. Most recent: inspection, 27 April 2026.

Built
2004
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI3686
695011
Flag
UNITED STATES
366973160, 367690870 (licence lapsed)
Maury page id
psix-695011

Inspections, by type

…with no type recorded7
…past their stated due date1
Years with a record 17 calendar years (2003–2026)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 18.8 ft × 10.0 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS INC · WETUMPKA, AL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI3686MMSI 367690870 · expired · compulsorily equipped · granted 1 September 2015, cancelled 7 March 2026
WDB9291MMSI 366973160 · expired · compulsorily equipped · granted 21 August 2004, cancelled 25 October 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 39

27 April 2026 Vessel Attendance · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8356478
19 December 2025 Internal Structural Exam · Administrative Inspection · Vessel Attendance · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285584
3 September 2025 Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226495
2 June 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8150884
4 February 2025 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8116475
24 April 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7901301
13 March 2024 Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7878907
30 January 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7852548
13 September 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7790924
10 April 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7667082
4 April 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7424747
27 January 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7386483
19 July 2021 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7257876
8 March 2021 Type not recorded
No type recorded · USCGC NORTHLAND (WMEC 904) · Activity 7152526
13 October 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7075905
30 January 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6900263
26 September 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6823002
13 August 2019 DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6783267
28 March 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6651788
8 September 2018 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6536215
30 August 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6526764
23 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340443
14 September 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6265849
2 June 2017 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6164180
7 July 2016 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5929955
21 January 2016 Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5800654
6 October 2015 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 5737201
6 October 2015 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5748079
1 September 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5231936
28 August 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4980498
19 July 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4383108
5 May 2012 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 4303711
1 February 2012 Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4234761
14 October 2010 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3867074
9 March 2010 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3859355
2 February 2010 Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3673698
16 September 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3323420
29 January 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3138585
9 January 2003 Hull Examination · Simplified Stability Test · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Internal Structural Exam · Initial Certification
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2619023

Deficiency record · 42

08 - Alarms › N/A - No Subsystem › General alarm
Issued 11 May 2026 No resolution recorded
Vessel's installed watchman device did not operate as required. Alarm can be silenced from operation station and accommodation space device timer cannot be reset when watch stander presses button. Vessel is prohibited from carrying overnight passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 11 May 2026 No resolution recorded
Vessel must have a means to recover a person from the water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2025 Resolved
Vessel's installed watchman device does not operate as intended. The alarm and interval set point can both be silenced/reset from the operating station. Vessel is prohibited from carrying more than 06 overnight passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2026
Resolution: 2026 Annual Inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2024 Resolved
Generator fuel filter missing metallic heat shield.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 June 2025
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 April 2024 Resolved
Hatch to lazarette needs to made watertight. Hatch was missing gasket and was not secured to deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 June 2025
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 24 April 2024 Resolved
Vessel Master did not have medical certificate onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 24 April 2024 Resolved
Watchman device in main accommodation space was inoperable. Vessel restricted to no more that 6 overnight passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 May 2024
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 24 April 2024 Resolved
Vessel did not have a Drug and Alcohol policy onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 1 May 2024
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 April 2023 Resolved
Test high water alarm. Engine compartment high water alarm float was blocked by grounding strap.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 13 September 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2023 Resolved
Test emergency fuel valves. Emergency fuel valves did not fully close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 13 September 2023
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2019 Resolved
Vessel required to have waterlight attached to the life float by a 18" line 3/8" wide that is resistant to ultraviolet deterioration. 46 CFR 180.175 (f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 26 September 2019
Resolution: Vessel crew provided and installed a line of correct length and width to the life float.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 September 2015 Resolved
Provide valid mariner license.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2015
Resolved 15 October 2015
Resolution: Vessel Capt provided valid license.
Lifesaving › Lifefloat › Retroreflective Material
Issued 1 September 2015 Resolved
Install retro on lifefloat
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 7 October 2015
Resolution: Vessel installed retro.
Communications › Radio Communications › EPIRB
Issued 1 September 2015 Resolved
Replace expired EPRIB battery. (Vessel limited to NMT 3NM)
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 7 October 2015
Resolution: Vessel replaced EPRIB
Construction/Loadline › Structures › Deck Plating
Issued 2 February 2010 Resolved
Re-bed drainage pipe through deck fitting in lazarette and prove water tightness with 30 psi hose test as per 46 CFR 176.800 to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Due 2 March 2010
Resolved 9 March 2010
Resolution: Drainage pipe was resealed. A 30 psi hose test was conducted and the repair was found to be satisfactory.
Construction/Loadline › Structures › Superstructure
Issued 2 February 2010 Resolved
Re-Weld port stanchion of tuna tower as required by 46 CFR 176.800 to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 2 March 2010
Resolved 9 March 2010
Resolution: Port stanchion of the tuna tower was properly re-welded.
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 2 February 2010 Resolved
Seal through bulkhead piping and wiring penetrations in engine room to maintain vapor tightness as required by 46 CFR 177.4015(c) to ensure effectiveness of fixed fire protection system.
Condition: Improper Installation
Due 2 March 2010
Resolved 9 March 2010
Resolution: Identified bulkhead penetrations were properly sealed.
Communications › Public Address System › Loudspeaker
Issued 16 September 2008 Resolved
Provide speaker for intercom in cabin.
Due 16 October 2008
Resolved 30 September 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 April 2006 Resolved
Provide current navigation safety publications, or extracts from, for area of intended operations as required by 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Navigation › Piloting/Steering › Marine Charts
Issued 7 April 2006 Resolved
Provide currently corrected marine charts of sufficient detail as required by 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Lifesaving › Hand Flares › Storage
Issued 7 April 2006 Resolved
Provide a storage container for VDS that is properly marked as required by 46 CFR 185.614.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 April 2006 Resolved
Post Emergency Broadcast Instructions in Pilot house as required by 46 CFR 184.506.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Communications › Radio Communications › EPIRB
Issued 7 April 2006 Resolved
Properly stow 406 MHZ CAT 1 EPIRB in a suitable float free arrangement as required by 46 CFR 180.64.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 7 April 2006 Resolved
Provide documentation to prove light transmission of not less than 70 percent according to Test 2 and 15 of ANSI Z 26.1(Safety Glazing and Class I Optical Deviation) as required by 46 CFR 177.1030(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Resolution: Sighted specification sheet for Oldcastle Glass - FLOAT GLASS ASTM C1048 Type I Class II Q3 tempered glass Visible light transmittance of 88%. See list of permanent documents DOC [withheld]/001.
Stability › Watertight Integrity › General
Issued 7 April 2006 Resolved
Prove that hatch cover to machinery space, that is exposed to the weather, is watertight and provide suitable securing devices as required by 46 CFR 179.360..
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Stability › Watertight Integrity › General
Issued 7 April 2006 Resolved
Demonstrate watertight integrity of lazarette hatch cover as required by 46 CFR 402(d).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Stability › Weathertight Integrity › General
Issued 7 April 2006 Resolved
Demonstrate weather tight integrity of the main deck passenger accommodation (salon) access door as required by 46 CFR 1176.402(d)
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 April 2006 Resolved
Provide a fixed deck rail on bow and gunwale around periphery of cockpit deck that meets minimum height requirements (36 inches) as required by 46 CFR 177.900(d)(4).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Lifesaving › Lifefloat › Painter
Issued 7 April 2006 Resolved
Properly stow life float in accordance with 46 CFR 180.137.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 April 2006 Resolved
Provide 3 Adult size Type I PFDs in serviceable condition approved under 46 CFR 160.055 in accordance with 46 CFR 180.71 and marked in accordance with 46 CFR 185.604.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 7 April 2006 Resolved
Provide an approved fire detection in accommodation spaces, service spaces and storage lockers that contain an ignition source such as electrical equipment as required by 46 CFR 177.410(c)(3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Resolution: Verified installation and operation of ANSUL IQ 301M Coast Guard Approval Number: 161 .002/A0023/4
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 April 2006 Resolved
Provide proper insulation or lining on forward machinery space bulkhead and machinery space that is approved in accordance with 46 CFR 160.009 or other approved standard as required by 46 CFR 177.410(c)(4).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Resolution: Suitable material installed meeting USCG 164.112/62/0. Meets or exceeds 160.009. See DOC [withheld]/002 list of vessel permanent documents for installed material specification.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 April 2006 Resolved
Provide provisions for closing machinery space (protected by a fixed gas fire extinguishing system) to make it vapor tight as required by 46 CFR 182.465(h) and 46 CFR 176.800(a).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Fire Fighting › Fire Bucket › Capacity
Issued 7 April 2006 Resolved
Provide bucket that meets 2.5 gallon capacity requirements, with an attached lanyard marked with the words FIRE BUCKET and stowed in a readily accessible location as required by 46 CFR 181.610.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 April 2006 Resolved
Prove that port, starboard and center diesel fuel tanks are electrically bonded to a common ground as required by 46 CFR 182.440(b)(4).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 7 April 2006 Resolved
Provide suitable marine type strainers that are fitted with a opening on top for cleaning and are metallic in construction on main propulsion engines as required by 46 CFR 182.455(b)(6).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Engineering › Lubricating Oil Service System › Hose
Issued 7 April 2006 Resolved
Provide suitable flexible hose that meet the requirements SAE J1942-1 on main diesel engines lubrication filtration system for marine applications as required by 46 CFR 182.720(e).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 7 April 2006 Resolved
Provide proper penetrations for diesel fuel transfer system fitted with non-metallic flexible hose that penetrate the aft machinery space bulkhead as required by 46 CFR 182,455(b)(3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Resolution: Close fitting ferrels installed at bulkhead penetrations.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 April 2006 Resolved
Provide proper non-metallic flexible hose installed on the propulsion engine primary sea water cooling systems that is marked with SAE J-1942-1 and as required by 46 CFR 182.720(e).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Engineering › Bilge Water Management System › Pump
Issued 7 April 2006 Resolved
Provide an electric submersible bilge pumps that is listed by Underwriter Laboratories or another USCG accepted independent laboratory as required by 46 CFR 182.520(e).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 April 2006 Resolved
Provide a properly installed visual indicator to indicate when any automatic bilge pump is in operation to be located behind heavily tinted glass panel at the operating station at the operating station that satisfies the requirements of 46 CFR 182.530(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 April 2006 Resolved
Provide a properly installed emergency lighting system in passenger accommodations below the main deck as required by 46 CFR 183.432.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 26 May 2006
Resolution: Installed and tested satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.