Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Documentation record
Registered dimensions (L × B × D)64.8 ft × 18.8 ft × 10.0 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS INC · WETUMPKA, AL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
27 April 2026
Vessel Attendance · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8356478
19 December 2025
Internal Structural Exam · Administrative Inspection · Vessel Attendance · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285584
3 September 2025
Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226495
2 June 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8150884
4 February 2025
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8116475
24 April 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7901301
13 March 2024
Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7878907
30 January 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7852548
13 September 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7790924
10 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7667082
4 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7424747
27 January 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7386483
19 July 2021
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7257876
8 March 2021
Type not recorded
No type recorded · USCGC NORTHLAND (WMEC 904) · Activity 7152526
13 October 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7075905
30 January 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6900263
26 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6823002
13 August 2019
DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6783267
28 March 2019
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6651788
8 September 2018
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6536215
30 August 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6526764
23 January 2018
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340443
14 September 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6265849
2 June 2017
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6164180
7 July 2016
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5929955
21 January 2016
Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5800654
08 - Alarms › N/A - No Subsystem › General alarm
Issued 11 May 2026
No resolution recorded
Vessel's installed watchman device did not operate as required. Alarm can be silenced from operation station and accommodation space device timer cannot be reset when watch stander presses button. Vessel is prohibited from carrying overnight passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 11 May 2026
No resolution recorded
Vessel must have a means to recover a person from the water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2025
Resolved
Vessel's installed watchman device does not operate as intended. The alarm and interval set point can both be silenced/reset from the operating station. Vessel is prohibited from carrying more than 06 overnight passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2026
Resolution: 2026 Annual Inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 April 2024
Resolved
Generator fuel filter missing metallic heat shield.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 June 2025
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 April 2024
Resolved
Hatch to lazarette needs to made watertight. Hatch was missing gasket and was not secured to deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 2 June 2025
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 24 April 2024
Resolved
Vessel Master did not have medical certificate onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 24 April 2024
Resolved
Watchman device in main accommodation space was inoperable. Vessel restricted to no more that 6 overnight passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 May 2024
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 24 April 2024
Resolved
Vessel did not have a Drug and Alcohol policy onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 1 May 2024
Resolution: Corrected
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 April 2023
Resolved
Test high water alarm. Engine compartment high water alarm float was blocked by grounding strap.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 13 September 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2023
Resolved
Test emergency fuel valves. Emergency fuel valves did not fully close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 13 September 2023
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2019
Resolved
Vessel required to have waterlight attached to the life float by a 18" line 3/8" wide that is resistant to ultraviolet deterioration.
46 CFR 180.175 (f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 26 September 2019
Resolution: Vessel crew provided and installed a line of correct length and width to the life float.