Records from 2006 to 2026. Most recent: inspection, 1 April 2026.
Inspection history · 29
1 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8340343
11 March 2026
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8324772
17 February 2026
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8311441
6 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8129252
22 April 2024
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7899788
13 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7878572
1 November 2023
Appeal
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818855
17 April 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670135
23 January 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7625971
6 December 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7605216
21 April 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7438118
14 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7403220
24 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7205778
22 February 2021
Examination of Repairs · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7144758
22 May 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6958022
3 February 2020
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6902351
27 January 2020
Hull Examination · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6877213
16 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6835380
15 May 2019
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6684273
9 April 2019
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6672944
8 April 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6671084
24 July 2018
Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6489425
17 May 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6416863
22 April 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6398839
22 February 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359560
25 May 2017
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6143370
9 October 2016
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6020447
10 May 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5873901
24 February 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5820931
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 April 2026
No resolution recorded
Vessel failed to log monthly EPIRB test and drills in log book.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 April 2026
Resolved
Light attached to life ring inoperable, needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 12 May 2026
Resolution: Marine inspector verified light attached to lifering is now operable.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 April 2026
Resolved
Inflatable life rafts not onboard due to servicing maintenance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2026
Resolved 12 May 2026
Resolution: Inflatable liferafts are now properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 April 2026
Resolved
Band on exhaust piping from main diesel engine not secure, water leaking from connection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 12 May 2026
Resolution: Marine inspector verified two bands on exhaust piping properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 April 2026
Resolved
Missing interlock bar on generator circuit breaker, install interlock bar.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2026
Resolved 18 August 2026
Resolution: Marine inspector verified deficiency was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Interconnected fire detection system not operational. Provide operational interconnected fire detection.
46 CFR 181.405(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2026
Resolution: Received video of fire detection fully operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of more than 65 feet in length must: (1) Be of a type approved in accordance with approval series 162.027; or (2) Be of a type recognized by the Commandant as being equivalent in performance. Current nozzle onboard vessel is plastic and does not meet 162.027. Provide nozzle that meets 162.027.
46 CFR 181.320(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2025
Resolved 6 May 2025
Resolution: New brass nozzle provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Fire hose damaged during testing. Provide new fire hose.
46 CFR 181.320
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2025
Resolution: New fire hose provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2024
Resolved
Found Breaker #35 taped in the open position in galley panel #1; vessel brought electrician in and terminated the connection in a junction box. Previously used for food warmer that is no longer present or utilized.
Action required: 10 - Deficiency Rectified
Resolved 23 April 2024
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 December 2023
Resolved
Several emergency escape signs were found worn. Emergency escape signage must be replaced
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2024
Resolved 23 April 2024
Resolution: Observed Signage, all SAT
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 December 2023
Resolved
Emergency escape did not have adequate instructions posted including how to bring down the ladder and that the hatch had to be pushed up.
Ensure adequate instructions are posted to aid passengers in using the emergency escapes and replaced emergency escape signage.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2024
Resolution: Vessel emailed images of instructions, all SAT
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 December 2023
Resolved
Emergency escape lighting was inadequate in the vicinity of the secondary emergency escape in bunk room I of aft berthing.
Install emergency lighting to light up secondary emergency escape and provide extra instruction to passengers of the escape at orientation until such time as this is completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2024
Resolved 23 April 2024
Resolution: Oserved emergency lighting, all SAT
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 23 December 2023
Resolved
During the egress drill, the secondary emergency escape from the aft berthing was found leading below a table in the salon.
By DDX 01MAY24, submit repair proposal and once approved remove table as an obstruction IWO hinge, leaf, etc.
Action required: 705 - Other - as specified
Due 23 January 2024
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021
Resolved
REPLACE 01 LINED COMMERCIAL FIRE HOSE (50'/UL 19).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 25 May 2021
Resolution: Picture of receipt and new fire hose received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2021
Resolved
PROVIDE UPDATED DRUG & ALCOHOL CONSORTIUM (ASTS) LIST WITH ALL EMPLOYEES WITH DESIGNATED SAFETY DUTIES.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 2 June 2021
Resolution: Received complete ASTS crew list.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 May 2021
Resolved
REMOTE FUEL SHUT-OFF VALVE ENCLOSURES FOUND SEIZED CLOSED.
Action required: 10 - Deficiency Rectified
Resolved 24 May 2021
Resolution: Crew were able to open caps and properly grease threads. POC stated they will start monthly maintenance on caps.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 May 2020
Resolved
Provide NOAA EPIRB registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 5 June 2020
Resolution: EPIRB registration provided via e-mail.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2020
Resolved
Provide child life jacket marking what is legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 28 May 2020
Resolution: Lifejacket marking provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2020
Resolved
Remove flammables from vessel specifically lazz and engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: Flammables removed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 May 2020
Resolved
Provide DSC capabilities on VFH radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: DSC provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 22 May 2020
Resolved
Provide MMC medical card for Brian.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: Medical card provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2020
Resolved
Remove hard wired surge protector under helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2020
Resolution: Surge protector removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2020
Resolved
Mount J-box at pump room entrance on bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: J-box mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2020
Resolved
Remove or hard wire blowers in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: Blowers removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 May 2019
Resolved
Submit the 2018 Drug and alcohol MIS report
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 16 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2019
Resolved
Renew all expired medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 22 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 May 2019
Resolved
Vessel is a Zone-3 vessel and is required to carry 12 parachute flares per SSD OCMI policies. Procure required flares prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 16 May 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 May 2019
Resolved
Renew port fire hose. Prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 16 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2019
Resolved
Provide deck hatch capture devices (lanyards/chains)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2019
Resolved
Renew deteriorated/worn Retro-reflective tape on AFT life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 May 2017
Resolved
Prove proper operation of emergency lighting prior to carrying overnight passengers or using lower accommodation spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2017
Engineering › Pressure Vessel › Relief Valve
Issued 25 May 2017
Resolved
Prove operation of air receiver relife valve prior to using the system.
Action required: 705 - Other - as specified
Due 2 October 2017
Resolved 2 October 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 9 October 2016
Resolved
STBD Engine #1 head experienced a scucked valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2016
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 10 May 2016
Resolved
Make ready Air reciever for inspection at next availability in San Diego.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2017
Resolution: Internal inspection completed.