APL GUAM

APL GUAM is a 2000 freight ship. The Coast Guard has recorded 42 inspections since 2016, most recently in April 2021, along with 41 deficiencies, 2 operational controls and 6 casualty investigations between 2016 and 2021.

Records from 2016 to 2021. Most recent: inspection, 7 April 2021.

Built
2000
Last inspected
7 April 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2021
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9229609
695929
Flag
UNITED STATES
Maury page id
psix-695929

Documentation record

Tonnage as PSIX records it13764 - Convention (Subpart B), Gross Ton
5157 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SHINSEIMARU Tank Ship · MISLE 1547701 · 21 March 2019 · activity 6650969

Inspection history · 42

7 April 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7170794
1 April 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7166659
25 January 2021 In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7130736
25 January 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7135514
13 October 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7075810
4 October 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7070858
24 September 2020 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7064661
23 September 2020 MTSA/ISPS Verification
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7070831
9 July 2020 MSP COI Oversight · Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7001330
29 June 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139742
19 June 2020 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6980773
15 June 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7139731
5 April 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6935504
25 March 2020 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6931635
19 February 2020 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6911283
17 December 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6861801
6 December 2019 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6869062
8 November 2019 Annual Inspection · Administrative Inspection · MSP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6859635
31 July 2019 Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6769133
25 July 2019 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6761255
22 March 2019 In-Service Inspection · Annual Inspection · ISM SMC Audit · Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6647118
21 March 2019 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6650969
8 December 2018 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6594007
14 November 2018 Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6575197
17 May 2018 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6685318
9 April 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6390836
12 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6336711
13 November 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6305452
24 August 2017 Deficiency Check · Security Breach · MTSA/ISPS Verification
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6250882
9 June 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6175420
2 February 2017 Deficiency Check · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6075752
11 October 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6019700
19 September 2016 Administrative Inspection · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6029003
26 June 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5937422
12 June 2016 ISM Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5909733
12 June 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5909796
24 May 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5884996
2 May 2016 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5866893
1 April 2016 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5844932
6 February 2016 Deficiency Check · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5811805
9 January 2016 Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5794252
8 January 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5808562

Deficiency record · 41

09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 July 2020 Resolved
74 SOLAS (2001) Chapter II-1, Regulation 26.1: The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which it they are intended and shall be so installed and protected as to reduce to a minimum danger to persons on board. The number 1, 2, and 3 generator is leaking fuel and oil that’s pooled underneath the engine and leaking down to the lower level of the engine room. The excessive leaks causes an unsafe condition and a fire hazard. Prior to vessel’s departure from COTP Guam, remove fuel and oil pooled underneath the generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2020
Resolution: Attended vessel and inspected no oily waste underneath generators. All satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 July 2020 Resolved
74 SOLAS (2014) Chapter III, Regulation 20: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Repair and prove operation of Rescue Boat hydraulic steering prior to departure from COTP Guam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2020
Resolution: Repair made to leaking hydraulic steering ram; new seal was replaced. Witnessed satisfactory tests of hydraulic steering.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 July 2020 Resolved
74 SOLAS (2001) Chapter II-1, Regulation 26.1: The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which it they are intended and shall be so installed and protected as to reduce to a minimum danger to persons on board. The number 1, 2, and 3 generator is leaking fuel and leaking down to the lower level of the engine room. The bilges shall be deep cleaned, degreased, and free of oil prior to return to U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 July 2020 Resolved
74 SOLAS (2014) Chapter III, Regulation 20.10: Containers, brackets, racks and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with recommendations of the Organization, indication the devices stowed in that location for that purpose. Replace weathered photo-luminescent placards for life saving equipment on port and starboard main deck and on exterior of house with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 13 July 2020 Resolved
74 SOLAS (2014) Chapter III, Regulation 20: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Large plastic container used to store first aid kit, flash light with extra batteries and other equipment required per LSA Code was inspected with water inside. Rescue boat must be fitted with contents per LSA Code Chapter 5/5.1.2.1 and 5.1.2.2 and shall be as small and of as little mass as possible and shall be packed in suitable and compact form. Replace large plastic non-watertight container with a smaller watertight container to prevent contents and equipment from water damage or store in rescue boat storage locker or compartments.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2020 Resolved
74 SOLAS (2014) Chapter II-2, Regulation 14.2.2.1: Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner due regard to ensuring the reliability of fire-fighting systems and appliances. Replace broken bracket on starboard main deck for CO2 portable fire extinguisher forward of paint locker with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2020
Resolution: New bracket installed to the satisfaction of MI.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 13 July 2020 Resolved
MARPOL Annex 1/17.2: The Oil Record Book Part 1 shall be completed on each occasion, on a tank-tank basis if appropriate, whenever any of the following machinery space operations takes place in the ship. The Oil Record Book contains multiple entries for oily waste transfers from engine room bilges to bilge holding tank using the incorrect code (D-15.5) during the period of January 03, 2020 to July 2020. Correct to the satisfaction of Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 3 August 2020
Resolution: See Class report attached under Deficiencies Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 July 2020 Resolved
74 SOLAS (2001) Chapter II-1, Regulation 26.1: The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which it they are intended and shall be so installed and protected as to reduce to a minimum danger to persons on board. The number 1, 2, and 3 generators are continuously leaking oil. Repair leaks from generators to the satisfaction of attending Class surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2020
Resolution: See Class report attached under Deficiencies Documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 July 2020 Resolved
74 SOLAS (2001) Chapter II-2, Regulation 13.1.13: The function of the detection system shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with incipient fires to which the detector is designed to respond. All detectors shall be of a type such that they can be tested for correct operation and restored to normal surveillance without the renewal of any component. The vessel does not have onboard the approved type of testing equipment for flame detectors. The testing has been conducted with an open flame which is not as per the manufacture's instruction and hazardous in a machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2020
Resolution: See Preliminary Class Report saved under Deficiencies Documents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 July 2020 Resolved
74 SOLAS (2001) Chapter I, Regulation 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to sea. Camlock fitting used as a temporary cap for port side fresh water fill line on main deck is loose and does not secure onto the top of the fill line. Replace missing cap for port side fresh water fill line on main deck with new to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 July 2020 Resolved
74 SOLAS (2001) Chapter I, Regulation 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to sea. Replace port side metal box with substantial wastage for port crane provision controls with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 December 2019 Resolved
The general alarm system shall be audible throughout all the accommodation and normal crew working spaces. The general alarm in the forward bow thruster room was not working, repair as original.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2019
Resolved 23 December 2019
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 17 December 2019 Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall comply with the following: in the event of a failure of a electrical power supply to the control system, an audible and visual alarm shall be given on the navigation bridge. During the test, the steering gear pump failure audible alarm discovered on the bridge failed to activate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 23 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 December 2019 Resolved
Cables and wirings shall be installed and supported in such a manner as to avoid chafing or other damage. The purifier exhaust fan connection box on main deck has loose wiring connections and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 23 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 17 December 2019 Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. The starboard bridge wing's rudder angle indicator is reading steering angles erratically.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 13 February 2020
Resolution: Both P/S bridge wing angle indicators were replaced with IP56 rated indicators. Steering gear was operated and tested in relation to helm indicator and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 December 2019 Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls. The launching instructions are missing in the vicinity of the rescue boat.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 23 December 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 December 2019 Resolved
Emergency Switchboard BUS-TIE (TERASAKI, P/N: XS225NS) failed to operate when in automatic mode. Emergency power source from Emergency generator can only be supply to Emergency Switchboard manually. Replace the malfunction BUS-TIE with in-kind BUS-TIE and conduct operational test to the satisfaction of the attending C.G Marine Inspector.
Action required: 705 - Other - as specified
Due 5 January 2020
Resolved 5 January 2020
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 23 March 2019 Resolved
The location of the controls of any valve serving a sea inlet, a discharge below the waterline or a bilge injection system shall be so sited as to allow adequate time for operation in case of influx of water to the space, having regard to the time likely to be required in order to reach and operate such controls. The main fire, bilge, and ballast pumps #1 and #2 were found to isolated due to excessive leaking seals, resulting in ingress of water into the bilge. The crew did not communicate to the company that isolation valves were closed, requiring additional time to align in case of emergencies.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 2 April 2019
Resolution: Vessels crew replaces the seals for #1 and #2 Fire, Bilge, and Ballast pumps located in the engineroom. Also, vessels internal audit identified a non-conformity by not following required reporting procedures. External audit schedled to take place 09APR19
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 March 2019 Resolved
The location of the controls of any valve serving a sea inlet, a discharge below the waterline or a bilge injection system shall be so sited as to allow adequate time for operation in case of influx of water to the space, having regard to the time likely to be required in order to reach and operate such controls. The starboard low suction sea valve is missing working parts and is arranged in a way that will not allow the valve to seat.
Action required: 30 - Ship detained
Resolved 2 April 2019
Resolution: Re issued this 835 to allow the vessel to transit to China for replacement in kind.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 March 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Sea water supply piping for the ships evaporator located before the skin isolation valve was found to be heavily pitted and in a substandard condition.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 2 April 2019
Resolution: HFO transfer piping was replaced in kind. This item remains a code 30C due to breakdown in required notifications to ABS and USCG.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Sea water supply piping for the ships evaporator located before the skin isolation valve was found to be heavily pitted and in a substandard condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2019
Resolution: Sea water piping was replaced in kind, downgraged the code from a 30C to a 17C due to evidence presented by the DPA and Port Engineer.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 23 March 2019 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. Complete an SMS external audit to be carried out by the RO prior to this ship being released from detention.
Action required: 30 - Ship detained
Resolved 2 April 2019
Resolution: Changed the code of the outstanding external audit to allow the vessel to transit to China to conduct the audit and complete permanent repairs to the bow damage.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 March 2019 Resolved
The location of the controls of any valve serving a sea inlet, a discharge below the waterline of a bilge injection system shall be so sited as to allow adequate time for operation in case of influx of water to the space, having regard to the time likely to be required in order to reach and operate such controls. The starboard low suction strainer isolation valve is missing working parts and is arranged with a temporary valve control.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 22 April 2019
Resolution: Received satisfactory report from ABS surveyor stating that both port and starboard strainer suction valves were replaced in kind serving both low and high suctions.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 22 March 2019 Resolved
The company and the ship shall comply with the requirements of the international safety management code. Complete an SMS external audit to be carried out by the RO, prior to departing Cosco Shipyard, Zhoushan, PRC.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 22 April 2019
Resolution: A satisfactory additional ISM external audit was conducted on 08APR19 at Zhoushan COSCO Shipyard by [name withheld] remained open until 21APR19 and report reviewed on 22APR19 by local OCMI. Report is attached to vessel documents. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 14 November 2018 Resolved
Put in Place permanent guard near aft shaft alley.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2018
Resolved 19 November 2018
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 November 2018 Resolved
Replace in kind mechanical seal on the #3 F/O booster pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2018
Resolved 19 December 2018
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 14 November 2018 Resolved
Install adequate insulation to the #3 DG Turbo.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2018
Resolved 19 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 November 2018 Resolved
Replace retro-reflective(Type II) on free fall lifeboat and rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2018
Resolved 19 December 2018
Engineering › Steam Boiler (auxiliary/waste heat) › Handhole
Issued 27 January 2018 Resolved
Handhole leaking past gasket on 2 handholes. To be corrected prior to departure from Guam.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 February 2018
Resolution: ABS Surveyor confirmed that gasket material was improper for the installation. Proper material replaced, boiler operationally tested SAT.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 27 January 2018 Resolved
Areas noted for repair in Forepeak and Fire Control Room, due to abrasion from traffic.
Action required: 705 - Other - as specified
Due 18 February 2018
Resolved 28 February 2018
Resolution: Received confirmation from ABS via Class Report that SFP covering was repaired to the satisfaction of the attending surveyor.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 January 2018 Resolved
1 Light broken on fo'c'sle and another with improper battery installed, causing it to sink below waterline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2018
Resolved 27 January 2018
Resolution: Both lights were fixed on the spot when found to be deficient.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 February 2017 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routing tests to ensure continuous reliable operation. The vessel’s Periodic Safety Test Procedures (PSTP’s) approval letter referenced by MSC Letter E2-1602896 dtd 08AUG16 is not available.
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: Service Report received. Deficiency cleared.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 2 February 2017 Resolved
The engineroom telegraph unit located at the operating station at the main diesel engine experienced intermittent faults. Troubleshoot and repair.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 16 February 2017
Resolution: Corrected and attested by ABS.
Engineering › Fuel Oil Service System › Valve
Issued 2 February 2017 Resolved
Multiple sounding tubes to tanks located below the freeboard deck that are fitted with gate valves do not have their handles attached. Reattach all handles.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 1 March 2017
Resolution: Corrected and attested by ABS.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 2 February 2017 Resolved
Lagging on the main diesel engine is oil-soaked and poses a fire hazard. Remove and replace all oil-soaked lagging.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 1 March 2017
Resolution: Corrected and attested by ABS.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 2 February 2017 Resolved
The safety relief valve located on the #1 start-air receiver did not reseat properly. Service relief valve or replace in kind.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 16 February 2017
Resolution: Corrected and attested by ABS.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 February 2017 Resolved
Emergency generator test equipment for automation testing was inoperable. Provide calibrated operable equipment.
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 16 February 2017
Resolution: Corrected and attested bt ABS.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 September 2016 Resolved
Crew member received injury to hand from rotating machinery on reefer compresser.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 12 October 2016
Resolution: ABS verified install of machinery guards over reefer compressor.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 14 June 2016 Resolved
Vsl is issued a Short Term IIAP certificate pending full term. Operator has been given 30-45 day extensions that must be valid prior to entering U.S. waters. See "Special Notes" for futher details regarding IAPP.
Action required: 705 - Other - as specified
Resolved 11 October 2016
Resolution: Vessel received required IAPP certs.
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 6 February 2016 Resolved
Vessel is not yet in receipt of valid Engine International Air Pollution Prevention Certificate following Re-Flag to U.S. FEACT authorizes issuance of a ST IAPP Certificate for 60 days from today or until its associated EIAPP Certificates have been processed and issued to the vessel by the EPA.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 15 June 2016
Resolution: CANCELED: No Update from EPA. Vessel received approved extension. Sector Guam to issue new CG835 for completion of new certificates by next US Port.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 9 January 2016 Resolved
Mechanical seal failure for No. 2 fire, bilge and ballast pump.
Action required: 705 - Other - as specified
Due 9 February 2016
Resolved 6 February 2016
Resolution: Class Society attended vessel in [name withheld] and witnessed satisfactory operational test of No. 2 fire, bilge and ballast pump.

Casualty record · 6

8 January 2016Routine · role: Involved in a Marine Casualty · activity 5808562
9 June 2017Routine · role: Involved in a Marine Casualty · activity 6175420
17 May 2018Routine · role: Involved in a Marine Casualty · activity 6685318
21 March 2019Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6650969
13 October 2020Routine · role: Involved in a Marine Casualty · activity 7075810
25 January 2021Routine · role: Involved in a Marine Casualty · activity 7135514
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.