KWAI is a 1950 freight ship. The Coast Guard has recorded 20 inspections since 2004, most recently in June 2020, along with 13 deficiencies and 1 operational control.
Records from 2004 to 2020. Most recent: inspection, 19 June 2020.
- Built
- 1950
- Last inspected
- 19 June 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
5038404 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
E5WB
696795
Flag
COOK ISLANDS
—
Maury page id
psix-696795
Inspections, by type
…with no type recorded2
Years with a record
13 calendar years (2004–2020)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it179 - Simplified, Gross Ton
74 - Simplified, Net Ton
74 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
19 June 2020
PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6980448
7 January 2020
PI Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6881258
2 October 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6826912
26 June 2019
ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6725789
2 November 2018
Loadline Exam · ISPS II Exam · In-Service Inspection · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6572181
24 January 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6343264
22 June 2017
Loadline Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6176046
20 May 2016
Loadline Exam · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5882245
23 June 2014
PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4877814
26 May 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4328681
4 May 2009
Loadline Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3467319
14 May 2008
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3206457
2 April 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3174944
4 April 2007
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2901968
7 February 2007
ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2798633
28 August 2006
ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2772395
23 November 2005
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2539810
20 July 2004
ISPS II Exam
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2133038
30 June 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2116756
28 June 2004
Deficiency Check
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 2113757
Deficiency record · 13
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 26 June 2019
Resolved
Deficiencies which may be deemed to pose a danger to persons, property or the environment include the following; Failure of seafarers to hold a certificate, to have a valid dispensation or to provide documentary proof that an application for endorsement has been submitted to the administration. Vessel has been in port for 6 days without licensed mate as required by minimum safe manning document.
STCW I/4.2.1
Navigation › Piloting/Steering › Marine Charts
Issued 23 June 2014
Resolved
1560-Charts-All vessels must carry adequate and up-to-date charts. Vessel does not have updated charts on board.-46 CFR 97.05-5(a).
Navigation › Piloting/Steering › US Coast Pilot
Issued 23 June 2014
Resolved
1570-Nautical Publications-All vessels must carry adequate and up-to-date U.S. Coast Pilots. Vessel does not have U.S. Coast Pilots available onboard.-46 CFR 97.05-5(c)
Construction/Loadline › Structures › Deck Plating
Issued 4 May 2009
Resolved
The ceiling of the port aft cabin which is also structural wood for the main deck, is damaged from an earlier fire. The deck is made watertight with a marine plywood overlay. (Temperary Repair)
ICLL Reg. 16/4
Construction/Loadline › Structures › Superstructure
Issued 4 May 2009
Resolved
The portlight assembly over the accomodatioin is wasted and holed near the bottom at main deck.
ICLL Reg. 16/4
Construction/Loadline › Markings › Load Line Mark
Issued 4 May 2009
Resolved
The hull is not marked in accordance with Load Line Certificate. There is no Plimsoll Mark.
ICLL Reg. 5
Construction/Loadline › Structures › Door
Issued 2 April 2008
Resolved
Main deck doors leading to the galley, engineroom and foc'sle have rotted, ill-fitting, or incomplete gaskets. ICLL Reg 16.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 April 2008
Resolved
The Chief Mate has no evidence of applying for a Cook Islands endorsement of his (Netherlands) license. STCW 1995.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 April 2008
Resolved
The fanbelt assembly on the aft end of the generator lacks a protective guard. Ports and Waterways Safety Act.
Construction/Loadline › Penetrations › Weld
Issued 7 February 2007
Resolved
Hatch cover to forward stores is comprised at the inner lip in corners.
Construction/Loadline › Markings › Load Line Mark
Issued 7 February 2007
Resolved
The port deck line and load line marks are rusted and/or faded.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 February 2007
Resolved
Lifejackets are not all provided with lights and whistles.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 7 February 2007
Resolved
The officer's licenses are not endorsed by the flag state.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.