DEMO BABY

DEMO BABY is a 1953 towing vessel. The Coast Guard has recorded 12 inspections since 1994, most recently in October 2025, along with 15 deficiencies.

Records from 1994 to 2025. Most recent: inspection, 20 October 2025.

Built
1953
Last inspected
20 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA3417
Flag
UNITED STATES
366798220
Maury page id
psix-69691

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (1994–2025)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)59.1 ft × 21.2 ft × 6.1 ft
Registered tonnagegross 68 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFABRI - STEEL CO · OAKLAND, CA, UNITED STATES · built 1953
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSOUTH NAKNEK, AK
Trade endorsementsRecreational, Registry
DocumentationValid · issued 23 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA3417MMSI 366798220 · active · compulsorily equipped · granted 13 November 2020, expires 23 January 2031 · licensed under a name not among this hull’s recorded names (not shown)
WCP7763MMSI not assigned · expired · compulsorily equipped · granted 25 January 1995, cancelled 2 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 12

20 October 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8251868
24 September 2025 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8204038
13 September 2024 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8000715
16 May 2024 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7913273
14 September 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7778863
12 September 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7557510
27 May 2021 Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7208720
27 January 2010 Industry Initiated Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3678125
15 November 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2821431
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1958097
12 November 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 9624
9 June 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 118062

Deficiency record · 15

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2025 Resolved
Provide 1 life jacket and immersion at watch station on Bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2025
Resolved 8 June 2026
Resolution: Vsl sold and COI deactivated.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 September 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The aft stern void hatch is inoperable and the forward hatch gasket material is dry-rotted. Make aft hatch operable and replace gasket on forward hatch. 46 CFR 140.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: The aft hatch was serviced and the forward hatch gasket replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 14 September 2023 Resolved
Decks and bulkheads designed to be watertight must be maintained in that condition. Severe wastage at the base of the STBD stack, approx 2'x1', and at the base of the port WTD, approx 1' x 6", was discovered. Provide plan to crop and renew back to good metal for the aforementioned areas prior to next operating season. 46 CFR 140.610(f) 24OCT2023: The vessel has been hauled out of the water for the winter season. The vessel rep will be assessing scope of repair work during this haul out period and submitting repair proposal. Repair work will be conducted in spring 2024 after review and approval of the proposal. Vessel rep will request attendance for verification of repair work prior to placing the vessel back into the water around the beginning of June.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 18 May 2024
Resolution: Wasted areas were cut back to good metal and new inserts were placed on the starboard stack and WTD.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 September 2023 Resolved
High bilge level alarms must be visible and audible at each operating station. The bilge high level alarm did not provide adequate audible notification at the operating station. Install adequate audible alarm at operating station. 46 CFR 143.230(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: An additional audible alarm was installed to provide notification to the bridge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 September 2023 Resolved
Each towing vessel must be equipped with navigation lights in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84. The port side running LED light is partially obstructed and not providing the required horizontal arc of visibility, install proper navigational light. 46 CFR 140.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: A new port side navigation light was installed.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 14 September 2023 Resolved
The master or officer in charge of a navigational watch must determine whether the vessel complies with all stability requirements in the vessel's stability letter. Bilges were found with several inches of standing oily water, pump bilges and provide documentation of removal in TVR. 46 CFR 140.605(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: The oily water from machinery space was removed and the bilges were cleaned.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2023 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” The machinery space and forward storage space were Carbon Dioxide is stored were not marked, properly mark entrances to spaces. 46 CFR 136.110 46 CFR 78.47-11(b)-(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: The machinery space and forward storage space were properly marked.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 September 2023 Resolved
All piping, valves, and fittings shall be securely supported, and where necessary, protected against injury. The CO2 branch line in the centerline overhead of the engine room had a broken support bracket and not properly supported. Repair support bracket. 46 CFR 136.110 46 CFR 76.15-15(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: The support bracket was repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2023 Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. The emergency exit from forward engine room was not marked, mark emergency exit. 46 CFR 144.160(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: The emergency exit was properly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2023 Resolved
Each watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. The watertight hatches and doors to the lazerette, machinery space, house, and forward storage space were not marked. Properly mark watertight hatches and doors. 46 CFR 140.160(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 24 October 2023
Resolution: The watertight hatches and doors to the lazerette, machinery space, house, and forward storage space were properly marked.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 September 2023 Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Fire drills have not been conducted since and recorded since June 30, 2023. 46 CFR 142.245(a)
Action required: 10 - Deficiency Rectified
Resolved 14 September 2023
Resolution: Fire drill was conducted and recorded in TVR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2021 Resolved
Vessel must have a type I Lifejacket for every person onboard. Vessel currently only has 02 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 2 August 2021
Resolution: 4 PFDs now onboard.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 May 2021 Resolved
Fire pump must deliver 50psi and be energized remotely from a safe place outside the engine room. Fire pump does not deliver 50 psi to hydrant and cannot be energized from outside the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 16 July 2021
Resolution: Vessel excepted from regulation as it only operates as a harbor assist tug in the vacinity of another inspected towing vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 May 2021 Resolved
The design and installation of the fire detection system must be certified by a professional engineer or NICET Level 4 alarm engineering technician. Installation is not certified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 16 July 2021
Resolution: Vessel excepted from regulation as it only operates as a harbor assist tug in the vacinity of another inspected towing vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2021 Resolved
All installed bilge piping must have check valves installed to prevent backflooding.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 14 September 2023
Resolution: check valves installed on bilge piping.