DEMO BABY is a 1953 towing vessel. The Coast Guard has recorded 12 inspections since 1994, most recently in October 2025, along with 15 deficiencies.
Records from 1994 to 2025. Most recent: inspection, 20 October 2025.
- Built
- 1953
- Last inspected
- 20 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
266460
WDA3417
69691
Flag
UNITED STATES
366798220
Maury page id
psix-69691
Inspections, by type
…with no type recorded2
Years with a record
10 calendar years (1994–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)59.1 ft × 21.2 ft × 6.1 ft
Registered tonnagegross 68 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFABRI - STEEL CO · OAKLAND, CA, UNITED STATES · built 1953
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSOUTH NAKNEK, AK
Trade endorsementsRecreational, Registry
DocumentationValid · issued 23 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDA3417MMSI 366798220 · active · compulsorily equipped · granted 13 November 2020, expires 23 January 2031 · licensed under a name not among this hull’s recorded names (not shown)
WCP7763MMSI not assigned · expired · compulsorily equipped · granted 25 January 1995, cancelled 2 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 12
20 October 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8251868
24 September 2025
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8204038
13 September 2024
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8000715
16 May 2024
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7913273
14 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7778863
12 September 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7557510
27 May 2021
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7208720
27 January 2010
Industry Initiated Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3678125
15 November 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2821431
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1958097
12 November 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 9624
9 June 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 118062
Deficiency record · 15
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2025
Resolved
Provide 1 life jacket and immersion at watch station on Bridge.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 September 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The aft stern void hatch is inoperable and the forward hatch gasket material is dry-rotted. Make aft hatch operable and replace gasket on forward hatch.
46 CFR 140.610(b)
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 14 September 2023
Resolved
Decks and bulkheads designed to be watertight must be maintained in that condition. Severe wastage at the base of the STBD stack, approx 2'x1', and at the base of the port WTD, approx 1' x 6", was discovered. Provide plan to crop and renew back to good metal for the aforementioned areas prior to next operating season.
46 CFR 140.610(f)
24OCT2023: The vessel has been hauled out of the water for the winter season. The vessel rep will be assessing scope of repair work during this haul out period and submitting repair proposal. Repair work will be conducted in spring 2024 after review and approval of the proposal. Vessel rep will request attendance for verification of repair work prior to placing the vessel back into the water around the beginning of June.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 September 2023
Resolved
High bilge level alarms must be visible and audible at each operating station. The bilge high level alarm did not provide adequate audible notification at the operating station. Install adequate audible alarm at operating station.
46 CFR 143.230(b)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 September 2023
Resolved
Each towing vessel must be equipped with navigation lights in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84. The port side running LED light is partially obstructed and not providing the required horizontal arc of visibility, install proper navigational light.
46 CFR 140.720
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 14 September 2023
Resolved
The master or officer in charge of a navigational watch must determine whether the vessel complies with all stability requirements in the vessel's stability letter. Bilges were found with several inches of standing oily water, pump bilges and provide documentation of removal in TVR.
46 CFR 140.605(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2023
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” The machinery space and forward storage space were Carbon Dioxide is stored were not marked, properly mark entrances to spaces.
46 CFR 136.110
46 CFR 78.47-11(b)-(c)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 September 2023
Resolved
All piping, valves, and fittings shall be securely supported, and where necessary, protected against injury. The CO2 branch line in the centerline overhead of the engine room had a broken support bracket and not properly supported. Repair support bracket.
46 CFR 136.110
46 CFR 76.15-15(f)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2023
Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. The emergency exit from forward engine room was not marked, mark emergency exit.
46 CFR 144.160(f)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2023
Resolved
Each watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. The watertight hatches and doors to the lazerette, machinery space, house, and forward storage space were not marked. Properly mark watertight hatches and doors.
46 CFR 140.160(e)
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 September 2023
Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Fire drills have not been conducted since and recorded since June 30, 2023.
46 CFR 142.245(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2021
Resolved
Vessel must have a type I Lifejacket for every person onboard. Vessel currently only has 02 lifejackets.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 May 2021
Resolved
Fire pump must deliver 50psi and be energized remotely from a safe place outside the engine room. Fire pump does not deliver 50 psi to hydrant and cannot be energized from outside the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 May 2021
Resolved
The design and installation of the fire detection system must be certified by a professional engineer or NICET Level 4 alarm engineering technician. Installation is not certified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2021
Resolved
All installed bilge piping must have check valves installed to prevent backflooding.