J. S. ST. JOHN

J. S. ST. JOHN is a 1945 freight ship. The Coast Guard has recorded 26 inspections since 2016, most recently in December 2025, along with 39 deficiencies and 4 casualty investigations between 2010 and 2021.

Records from 2010 to 2025. Most recent: inspection, 29 December 2025.

Built
1945
Last inspected
29 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 December 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

5202524
WDE4111
Flag
UNITED STATES
Maury page id
psix-69793

Documentation record

Registered dimensions (L × B × D)165.8 ft × 31.9 ft × 15.0 ft
Registered tonnagegross 415 / net 282
ITC dimensions (L × B × D)165.8 ft × 31.9 ft × 15.0 ft
ITC tonnageNot recorded
BuilderSMITH SHIPYARDS INC · PENSACOLA, FL, UNITED STATES · built 1945
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portERIE, PA
Trade endorsementsCoastwise, Bowaters
DocumentationValid · issued 20 January 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it415 - Regulatory (Subpart C or D), Gross Ton
282 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

26 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each; 4 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

29 December 2025 Examination of Repairs · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8290226
5 June 2025 Periodic Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8153529
13 March 2025 Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8095592
8 January 2025 Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8060132
4 June 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7929929
17 April 2024 In-Service Inspection · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7897474
17 April 2023 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7671012
14 December 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7610066
19 July 2022 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7511145
25 January 2022 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7385536
13 December 2021 Administrative Inspection · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7369674
15 May 2021 Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7197459
15 May 2021 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7225926
5 May 2021 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7195795
26 April 2021 Damage Survey · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7182920
24 May 2020 Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6963177
24 May 2020 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6968646
30 April 2020 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6948128
3 May 2019 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6678668
29 April 2019 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6673782
17 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6542281
7 June 2018 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6437304
3 April 2017 Deficiency Check · COI Inspection · MTSA Verification · Security Plan Review - VSP · VRP Review · DAPI Audit · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6116892
16 November 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6042352
22 August 2016 In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6001544
10 June 2016 In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5914497

Deficiency record · 39

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 March 2025 Resolved
Submit repair proposal to complete repair of fracture/inset of port side side shell prior to operating.
Action required: 705 - Other - as specified
Resolved 31 March 2025
Resolution: Attended Vessel to conduct NDT of inserted plate. No Discrepancies found.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 January 2025 Resolved
OCMI was not notified of vessel repairs until repairs had already been made to the vessels deck plating. No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the OCMI.
Action required: 705 - Other - as specified
Due 8 January 2025
Resolved 8 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2024 Resolved
Bridge lifering floating wsaterlight had a damaged battery. Ships crew replaced battery immediatly. Deficiency cleared on the spot.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 April 2023 Resolved
Electric installations on vessels must ensure protection of passengers and crew from electrical hazards. Vessel Owner/Operator shall install blank covers and remove breakers no longer in serviceable condition in the vessel's breaker panels to protect passengers and crew from potential electrical hazards.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2023
Resolved 21 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2023 Resolved
Piping whose temperature exceeds 150 degrees shall be suitably insulated to preclude injury to personnel. Vessel owner/operator shall install guards/lagging on the vessels #2 generator to ensure safety of the crew.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 26 April 2023
Resolution: Received objective evidence
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 April 2023 Resolved
Electric equipment must be arranged to prevent damage from dripping liquids. Vessel owner operator shall secure the deck opening located above the distribution panel to ensure protection from wet and corrosive environments.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 May 2023
Resolved 21 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2023 Resolved
Main propulsion machinery must be provided with automatic shut-off controls in the event of a failure that could lead rapidly to complete breakdown, serious damage or explosion. Vessel owner shall ensure proper operation of the MDE over speed alarm circuitry.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 26 April 2023
Resolution: received objective evidence
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 17 April 2023 Resolved
No person may operate a U.S. non-oceangoing ship in the navigable waters of the United States, unless it has the capacity to retain on board all oily mixtures and is equipped to discharge these oily mixtures to a reception facility. Shaft packing was leaking excessively, adjust packing to manufacturer recommendations.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2023
Resolved 18 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 May 2022 Resolved
Low lube oil shut down was inoperable
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2022
Resolved 27 May 2022
Resolution: Vessel provided objective evidence of operating LO shutdown.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 May 2022 Resolved
Forward cargo deck watertight door was not closing properly
Action required: 10 - Deficiency Rectified
Resolved 26 May 2022
Resolution: Door was adjusted. Corrected on spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 May 2022 Resolved
Spanner wrench was missing from forward fire hose station.
Action required: 10 - Deficiency Rectified
Resolved 26 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2022 Resolved
Floating waterlight batteries were expired.
Action required: 10 - Deficiency Rectified
Resolved 26 May 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 May 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel's air compressor (general air) motor caught on fire and was placed out of commission. Due to vessel utilizing this equipment for engine start air, vessel must repair prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2021 Resolved
Vessel suffered a loss of propulsion marine casualty due to a failure of the jacket water pump. Make repairs to pump and ensure proper operation of propulsion system to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Civil Liability for Oil Pollution Damage Cert.
Issued 26 April 2021 Resolved
Vessel does not have a valid Certificate of Financial Responsibility. A vessel over 300 gross tons is required to maintain a valid Certificate of Financial Responsibility. Establish and prove proper Certificate of Financial Responsibility to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 May 2020 Resolved
Bulkheads at ends of enclosed superstructures must have sufficient strength to withstand impact of boarding seas. Vessel reported wasted bulkhead in way of #2 stbd ballast tank. Dredge spoils from suction hopper breaching bulkhead. Require report from load line assigning authority stating condition of damage, cause of damage and accepted repair to the satisfaction of Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 May 2020
Resolution: Class report received. See (J.S. ST. JOHN Class Report.pdf)attached to this activities documents section.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2020 Resolved
Hull repair proposal within the #2 ballast tank port side shell plating found fractured/leaking with a 1” crack in length located between frames #17 & 18 @ 12’ below main deck. Authorized temp repair, cement box patch, to be monitor & repaired at next haul out.
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 2 June 2022
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 29 April 2019 Resolved
Remove oil and water from engine room bilge.
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Bilges pumped to holding tank for shoreside discharge prior to MI's departure.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 April 2019 Resolved
Provide current EPIRB Registration prior to operation outside of three miles.
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Registration provided prior to MI's departure however to clear requirement provide photo of sticker on EPIRB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2019 Resolved
Complete adjustment of emergency bilge pump valve found leaking.
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Adjustment completed prior to MI's departure with sat results.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 April 2019 Resolved
Remove bubbler lines passing through starboard side engine room forward bulkhead flanged fitting. Provide and install blank prior to getting underway.
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Engineer removed hose and secured access cover prior to MI's departure.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2019 Resolved
Provide wire supports and wire protection through vessel; engine room, fiddly overhead and ivo battery installation, bow thruster room.
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 6 May 2019
Resolution: Received email from Master attesting to sat installation with additional areas identified and corrected. MI to verify during next visit to Erie, PA.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2019 Resolved
Plug holes in electrical junctions boxes throughout vessel; 2 in engine room, fiddly, bow thruster room.
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 6 May 2019
Resolution: Received email from Master attesting to the satisfactory repairs. MI to verify during next visit to Erie, PA.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2019 Resolved
Bow thruster room; provide bilge pickup line screen.
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
Resolution: Corrected prior to MI's departure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 April 2019 Resolved
Bow thruster room; provide status of replacement solenoid actuator. System inoperative at time of inspection - installation deemed aux machinery for operations.
Action required: 705 - Other - as specified
Due 29 April 2019
Resolved 14 May 2019
Resolution: Received email from Master attesting to sat installation and testing of solenoid.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 April 2019 Resolved
Provide battery box covers at all locations.
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 6 May 2019
Resolution: Received email from Master attesting to the installation of battery box covers for all installations.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 29 April 2019 Resolved
Main deck starboard side deck house water tight door; replace upper section of gasket with properly angled cuts.
Action required: 705 - Other - as specified
Due 10 May 2019
Resolved 6 May 2019
Resolution: Received email from Master attesting to the satisfactory repairs of gasket.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 April 2019 Resolved
Winter work; Crop and renew wasted decks and bulkheads sections. Noted several small holes IVO pilot house, main deck leading to engine room and fiddly.
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 2 June 2022
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 September 2018 Resolved
Vsl is broadcasting: No static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 15 October 2018
Resolution: https://www.marinetraffic.com/en/ais/details/ships/shipid:965443/mmsi:367348910/imo:5202524/vessel:J_S_ST_JOHN provides vessel draft is 3.9 m after o/o power cycled unit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2018 Resolved
Label source of outlet within pilot house.
Action required: 10 - Deficiency Rectified
Due 7 June 2018
Resolved 7 June 2018
Resolution: Corrected prior to MI's departure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 June 2018 Resolved
Prove proper operation of aft nav light.
Action required: 10 - Deficiency Rectified
Due 7 June 2018
Resolved 7 June 2018
Resolution: Corrected prior to MI's departure
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2018 Resolved
Provide additional hard wired outlet within pilot house
Action required: 10 - Deficiency Rectified
Due 7 June 2018
Resolved 7 June 2018
Resolution: Corrected prior to MI's departure.
Communications › Alarms/Indicators › General Alarm
Issued 9 May 2017 Resolved
Properly mark general alarm visual indicator beacons
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 June 2018
Resolution: Witnessed sat test of system with marking attached during inspection.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 9 May 2017 Resolved
Prove proper operation of emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 June 2018
Resolution: Witnessed proper operation during annual inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 9 May 2017 Resolved
Properly mark firefighting and lifesaving equipment locations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 June 2018
Resolution: Witnessed satisfactory marking.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 9 May 2017 Resolved
Prove proper operation of main propulsion engine high water temperature alarm and low lube oil pressure shutdown.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 June 2018
Resolution: Witnessed sat test of mde alarms and shutdowns.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 9 May 2017 Resolved
Provide proof of Certificate of Financial Responsibility
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 June 2018
Resolution: Certificate provided.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 9 May 2017 Resolved
Prove proper operation of both generator overspeed shutdowns, high water temperature alarms, and low lube oil shutdowns
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 June 2018
Resolution: MSE Policy provides that units are below the required hp requiring shutdowns.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 9 May 2017 Resolved
Provide proof of compliance with the National Pollutant Discharge Elimination System.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 June 2018
Resolution: System approvals provided.

Casualty record · 4

10 September 2010Routine · role: Involved in a Marine Casualty · activity 3954223
27 April 2011Routine · role: Involved in a Marine Casualty · activity 4001410
5 May 2021Routine · role: Involved in a Marine Casualty · activity 7195795
15 May 2021Routine · role: Involved in a Marine Casualty · activity 7225926
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.