Records from 2004 to 2018. Most recent: operational control imposed, 3 August 2018.
Inspection history · 19
2 August 2018
Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6498793
15 January 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3664425
18 December 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3382142
11 December 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3380545
5 June 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3226131
18 December 2007
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3117368
10 January 2007
Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2853432
29 July 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2728594
28 July 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2727626
26 May 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2659737
20 August 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2468749
19 August 2005
MARPOL Annex V Examination · ILO-147 Exam · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · PII Safety Exam · STCW 95 Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2468054
24 June 2005
ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2401941
25 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2341933
5 March 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2304004
27 October 2004
ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2229362
21 September 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2203534
6 July 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2122969
6 July 2004
ISPS II Exam · PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2123808
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2018
Resolved
SOLAS(14)II-2/4.2.2; 30(a)(b)(c); THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. THE FUEL OIL SUPPLY LINE, FROM THE MAIN FUEL RAIL, TO THE #8 AND #9 HIGH PRESSURE FUEL PUMP WAS ACTIVELY LEAKING APPROXIMATELY 01 LITRE PER MINUTE.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2018
Resolved
SOLAS(14)II-2/14.2.1.1.2; 30(a)(b)(c); THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFOMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. CARGO HOLD SAMPLE EXTRACTION SYSTEM JUNCTION BOXES, IN THE CO2 ROOM, ARE MISSING COVERS AND WASTED, ALLOWING THE SAMPLE TO ESCAPE INTO THE SPACE AND PREVENTING IT FROM BEING DETECTED.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2018
Resolved
SOLAS(14)II-2/4.1.1; 30(a)(b)(c); MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO DISCOVERED OIL SOAKED LAGGING ON THE FUEL DELIVERY LINES ON 04 SHIP SERVICE GENERATORS, HFO LINES UNDER THE FORWARD PART OF THE PURIFIER ROOM, AND THROUGHOUT THE PURIFIER ROOM.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2018
Resolved
SOLAS(14)II-2/4.2.2; 30(a)(b)(c); THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. FUEL OIL CATCHMENTS, MADE OF BUCKETS WITH FABRICATED SPOUTS, WERE DISCOVERED HANGING UNDER A LEAKING FUEL OIL RETURN LINE NEAR THE M/E #1 CYLINDER.
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2018
Resolved
SOLAS(14)II-2/14.2.1.1.2; 30(a)(b)(c); THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. ENGINE ROOM WORK SHOP'S FIRE DETECTION ZONE DISABLEMENT SWITCH WAS FOUND WITH ITS TIMER REMOVED AND WAS REPLACED WITH A HARD WIRED TOGGLE SWITCH. PSCO TESTED SMOKE DETECTOR IN THE SPACE SATISFACTORILY.
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2018
Resolved
SOLAS(14)II-2/14.2.1.1.2; 17(a)(c); THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. SMOKE DETECTORS THROUGHOUT THE PURIFIER ROOM, SHIP SERVICE GENERATOR ROOMS, AND ENGINE ROOM WERE DISCOVERED HANGING BY THEIR ELECTRICAL WIRES OR IMPROPERLY SECURED WITH CABLE TIES.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 August 2018
Resolved
SOLAS(14)III/20.2; 17(a)(c); BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. SELF IGNITING LIGHT ON THE STARBOARD SIDE NEAR THE GANGWAY WAS DISCOVERED WITH ALL OF THE INTERNAL COMPONENTS MISSING AND ONLY PLASTIC HOUSING REMAINING.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 5 March 2005
No resolution recorded
Vessel failed to submit an updated advanced notice of arrival at least 12 hours prior to entering the Port of Charleston, South Carolina.
Condition: Unknown
Action required: 705 - Other - as specified
Resolution: Vessel was ordered to leave the Port of Charleston and not allowed back into the Port of Charleston until the vessel was in full compliance with 33 CFR 160 Subpart C.