Records in 2018. Most recent: operational control imposed, 3 August 2018.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2018
Resolved
SOLAS(14)II-2/4.2.2; 30(a)(b)(c); THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. THE FUEL OIL SUPPLY LINE, FROM THE MAIN FUEL RAIL, TO THE #8 AND #9 HIGH PRESSURE FUEL PUMP WAS ACTIVELY LEAKING APPROXIMATELY 01 LITRE PER MINUTE.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2018
Resolved
SOLAS(14)II-2/14.2.1.1.2; 30(a)(b)(c); THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFOMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. CARGO HOLD SAMPLE EXTRACTION SYSTEM JUNCTION BOXES, IN THE CO2 ROOM, ARE MISSING COVERS AND WASTED, ALLOWING THE SAMPLE TO ESCAPE INTO THE SPACE AND PREVENTING IT FROM BEING DETECTED.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2018
Resolved
SOLAS(14)II-2/4.1.1; 30(a)(b)(c); MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO DISCOVERED OIL SOAKED LAGGING ON THE FUEL DELIVERY LINES ON 04 SHIP SERVICE GENERATORS, HFO LINES UNDER THE FORWARD PART OF THE PURIFIER ROOM, AND THROUGHOUT THE PURIFIER ROOM.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2018
Resolved
SOLAS(14)II-2/4.2.2; 30(a)(b)(c); THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. FUEL OIL CATCHMENTS, MADE OF BUCKETS WITH FABRICATED SPOUTS, WERE DISCOVERED HANGING UNDER A LEAKING FUEL OIL RETURN LINE NEAR THE M/E #1 CYLINDER.
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2018
Resolved
SOLAS(14)II-2/14.2.1.1.2; 30(a)(b)(c); THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. ENGINE ROOM WORK SHOP'S FIRE DETECTION ZONE DISABLEMENT SWITCH WAS FOUND WITH ITS TIMER REMOVED AND WAS REPLACED WITH A HARD WIRED TOGGLE SWITCH. PSCO TESTED SMOKE DETECTOR IN THE SPACE SATISFACTORILY.
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2018
Resolved
SOLAS(14)II-2/14.2.1.1.2; 17(a)(c); THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS: FIRE DETECTION AND FIRE ALARM SYSTEMS. SMOKE DETECTORS THROUGHOUT THE PURIFIER ROOM, SHIP SERVICE GENERATOR ROOMS, AND ENGINE ROOM WERE DISCOVERED HANGING BY THEIR ELECTRICAL WIRES OR IMPROPERLY SECURED WITH CABLE TIES.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 August 2018
Resolved
SOLAS(14)III/20.2; 17(a)(c); BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. SELF IGNITING LIGHT ON THE STARBOARD SIDE NEAR THE GANGWAY WAS DISCOVERED WITH ALL OF THE INTERNAL COMPONENTS MISSING AND ONLY PLASTIC HOUSING REMAINING.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2018
Resolution: PSCO/RO attended vessel and verified rectification of deficiency.