Records from 2005 to 2026. Most recent: inspection, 28 May 2026.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 11.0 ft × 4.5 ft
Registered tonnagegross 13 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCANAL BOATS INC · FORT LAUDERDALE, FL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
28 May 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8382381
23 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8117823
29 May 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7915650
9 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7892216
12 September 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7789644
8 August 2022
Simplified Stability Test
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7546039
19 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7433687
15 April 2022
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7431027
25 May 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7195229
14 August 2020
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7034784
23 June 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6984739
19 June 2019
COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6717895
15 October 2018
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6559171
7 June 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6431132
30 August 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6257068
29 September 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6013004
28 June 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5920917
1 February 2016
Deficiency Check · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5809726
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with the manufacturer's instructions.
Pre-engineered system found discharged with 4 points of corrosion on the underside of bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2025
Resolution: Vessel provided report of newly installed pre-engineered system. Operational checks to include shut downs were conducted by third party and MI
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 May 2024
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge.
Found that the fixed fire pump does not have a pressure gauge installed. Gauge needs to be installed at the outlet side of the discharge piping.
46 CFR 181.300
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 12 June 2024
Resolution: Vessel installed fire pump pressure gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
No labeling for location of the fuel shut off. Proper labeling shall be installed to clearly mark where the fuel shut off valve is located.
46 CFR 185.608
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 5 June 2024
Resolution: Clearly marked fuel shut off with labeling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to...provide services necessary for safety under normal and emergency conditions.
Found that the axillary generator's remote start is inoperable and the only means of starting is be jumping connectors on the generator.
46 CFR 183.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 5 June 2024
Resolution: Aux gen wireing repaired and corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 April 2022
Resolved
A visual indicator must be provided at the operating station to indicate the operation of any automatic bilge pump. Lights at the operating station for the forward and engine compartments don't work. Replace or repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2022
Resolution: Received video evidence of the visual panel for the high level alarms working properly. Cleared 835.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2022
Resolved
Vessels less than 65 feet and carrying over 49 passengers are required to have a fire hose and pump. Fire hose has small holes and need to be replaced.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personal injury. Engine breather was creating thick oil vapor inside engine room. Inspect and repair as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2021
Resolved 7 June 2021
Resolution: Crew re-routed breather hose, and connected to turbo inlet as per manufactures specifications.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personal injury. Engine auxiliary belt was misalign and was shaving against water hose. Complete repairs IAW manufacturer specifications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 7 June 2021
Resolution: Crew adjusted belt IAW manufacters specs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 May 2021
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. There is a penetration between engine room and space 2 where old steering shaft used to go through. Seal as required to meet watertight integrity and to prevent fire extinguishing agent from escaping space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2021
Resolved 7 June 2021
Resolution: Crew added fire retardant foam in bulkhead penetration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personal injury. Theres excessive oil residue on engineroom ceiling, engine alternator and engineroom bilges. Find source and correct as per manufacturers specifications.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2021
Resolved 7 June 2021
Resolution: Crew cleaned all surfaces.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personal injury. Steering azipod is leaking. Find source and correct.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 30 June 2021
Resolution: Crew waiting on parts from Canada. Receipt was presented as proof of order.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 May 2021
Resolved
Each collision bulkhead required must not be fitted with any type of penetrations or opening except penetrations may be made if they are watertight. Theres is a gap on watertight bulkhead that needs to be sealed and made watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 7 June 2021
Resolution: Crew added fire retardant foam in cable runs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021
Resolved
Each life jacket must be marked with Type II retroreflective material ... 12 Life jackets need new tape. Repair IAW CFR
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2021
Resolved 7 June 2021
Resolution: All life jackets retroreflective tape was replaced. All sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 August 2020
Resolved
Replace retro-reflective tape on five identified lifejackets.
Action required: 10 - Deficiency Rectified
Resolved 16 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2019
Resolved
46 CFR 180.71 (a)(c)- The vessel must be equipped with adult life jackets provided for each passenger carried on board. Life jackets must be approved in accordance with subchapter Q. Lifejacket hooks on 09 lifejackets are missing proper latches. Passenger count reduced to 51.
Action required: 705 - Other - as specified
Resolved 2 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 July 2019
Resolved
46 CFR 185.604 (g)- Liferings on a vessel must be in accordance with subchapter Q. Each lifejacket must be marked with type I retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 August 2019
Lifesaving › Lifebuoys › Serviceable
Issued 30 August 2017
Resolved
Vessel must replace life ring prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 30 August 2017
Resolution: Replaced life bouy
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 February 2016
Resolved
Transmission cooler failed and the vessel loss propulsion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 February 2016
Resolution: Vessel replaced transmission cooler in kind.