MTM COLORADO is a 2004 tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in January 2023, along with 4 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 24 January 2023.

Built
2004
Last inspected
24 January 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 January 2023
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9278052
702081
Flag
SINGAPORE
Maury page id
psix-702081

Documentation record

Tonnage as PSIX records it30095 - Convention (Subpart B), Gross Ton
13701 - Convention (Subpart B), Net Ton
51231 - Dead Weight, Ton
61582 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE Towing Vessel · MISLE 92300 · 3 February 2021 · activity 7137692MARY KAY Towing Vessel · MISLE 136470 · 3 February 2021 · activity 7137692

Inspection history · 9

24 January 2023 PSC A · COC-CHEM Renew
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7626081
16 February 2022 Deficiency Check · PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7396709
1 March 2021 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7148054
3 February 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7137692
31 January 2021 COC-CHEM & TVE Renew
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7129411
12 February 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6086880
25 August 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5977167
14 June 2016 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5906955
8 June 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5901341

Deficiency record · 4

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 February 2022 Resolved
Each high level and overfill alarm must activate a visual alarm that can be seen in the cargo deck area. PSCO was unable to see any visual alarms for the high level or overfill. 46CFR39.2007
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 18 February 2022
Resolution: Received documentation and visual confirmation that the high level/ over fill alarm was repaired and is now fully operational
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 February 2022 Resolved
The fire detection and fire alarmsystems shall be kept in good order so as to ensure their required preformance if a fire occurs. smoke detector above main generator found to be inoperable. SOLAS 74(2020 Cons.)II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Due 16 February 2022
Resolved 16 February 2022
Resolution: Cleared on the spot
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 January 2021 Resolved
Ships shall be maintained in compliance W/ the structural requirements of a classification society, ship has damage in way of fore peak tank on port side and is taking water. Damage was caused by TUG during mooring operations.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2021
Resolved 1 March 2021
Resolution: Recieved Class survey report attestingn to repairs.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 31 January 2021 Resolved
For Tankers of 20,000 DWT and upwards, the protection of cargo tanks shall be achieved by a fixed inert gas systems, vessel's IGG has a faulty O2 analyzer. Vessel is restricted from loading those cargo listed in the IBC code as requiring inerting and is restricted from loading MARPOL Annex I cargoes requiring inerting.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 1 March 2021
Resolution: Recieved Class report attesting to replacement of O2 analzyzer.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.