← All vessels
FOTU O SAMOA II
FOTU O SAMOA II is a 1998 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2004, most recently in March 2026, along with 100 deficiencies — 5 with no resolution recorded — and 2 operational controls.
Records from 2004 to 2026. Most recent: inspection, 23 March 2026.
- Built
- 1998
- Last inspected
- 23 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 100 recorded · 5 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9220756 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5WCU
702094
Flag
SAMOA
—
Maury page id
psix-702094
Inspections, by type
…with no type recorded1
…past their stated due date1
Years with a record
17 calendar years (2004–2026)
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it299 - Convention (Subpart B), Gross Ton
89 - Convention (Subpart B), Net Ton
89 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 38
23 March 2026
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 8330771
7 January 2025
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 8059779
25 November 2024
PSC B
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 8040022
2 July 2024
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7947756
10 June 2024
PSC B
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7932255
9 December 2022
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7607083
15 November 2022
PSC B
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7594945
8 July 2021
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7250064
13 May 2021
Deficiency Check · PSC B
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7196415
30 July 2020
PSC B · ISPS Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 7021317
14 March 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6641398
5 March 2019
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6636776
13 February 2019
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6625368
29 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6589523
21 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6585118
13 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6579972
23 October 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6566220
16 October 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6562629
11 October 2018
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6557833
4 October 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6555174
25 September 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6548626
18 September 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6543639
12 September 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6539216
4 September 2018
Administrative Inspection
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6532216
5 April 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6386273
10 August 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6237789
21 July 2017
In-Service Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6215673
20 July 2017
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6216481
15 September 2016
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6044005
15 August 2016
Deficiency Check · NPV Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6003238
9 March 2016
ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 5830431
4 August 2015
Deficiency Check · ISPS II Exam · PII Safety Exam · ISM Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 5186679
21 June 2012
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4391567
6 August 2011
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4111629
28 January 2010
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3675084
16 June 2008
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3240926
24 September 2007
PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3066232
13 July 2004
ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2131820
Deficiency record · 100
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 November 2024
Resolved
Fixed fire detection and fire alarm systems for periodically unattended machinery spaces. PSCO found the vessels installed fixed fire detection system in the engine room was not operational. The vessel has installed two household style smoke detectors above each main engine. 74 SOLAS (1997)CH II-2 REG 14.1-.3
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 November 2024
Resolved
Machinery spaces of category A containing internal combustion machinery shall be provided with: One of the fire-extinguishing systems required by paragraph 1.1. After review of service certificates for the ships fixed fire extinguishing system PSCO discovered the findings from servicing companies 12SEP2024 report as follows: Cylinders 3 years overdue for hydrotest, Cylinders Low in CO2/Empty and are currently ineffective, hoses not replaced at 10 years and are showing damage and need replaced, alarm switch has been removed and should be reconnected, pin to hold center valve actuator in place is missing and needs to be replaced, blow through of manifold, distribution valve test not completed as no air compressor available on board. During visual inspection of system and piping PSCO observed heavy corrosion to system and piping. 74 SOLAS (1997)CH II-2 REG 7.2.1
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 November 2024
Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed crew attempting to operate all five remote fuel shut offs all five failed to operate. 74 SOLAS (1997)CH II-2 REG 15.2.5
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. During inspection in the vessels engine room PSCO’s carbon monoxide detector alarmed alerting to detectable presence of Carbon Monoxide, additionally PSCO observed a cloudy haze in engine room, and identified the distinct smell of engine exhaust, suggesting a significant exhaust leak.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 November 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. During inspection in the vessels engine room PSCO’s carbon monoxide detector alarmed alerting to detectable presence of Carbon Monoxide, additionally PSCO observed a cloudy haze in engine room, and identified the distinct smell of engine exhaust, suggesting a significant exhaust leak. 74 SOLAS (2004)CH I REG 11
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 November 2024
Resolved
Where necessary, oil fuel and lubricating oil pipelines shall be screeened or otherwise protected to avoid oil spray or oil leaks on to hot surfaces or into air intakes. The PSCO observed oil pooling on the flange of the turbo charger. 74 SOLAS (1997)CH II-2 REG 15.5.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2024
Resolved
In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapours. Lagging was missing adjacent to pipe leading to turbo charger resulting in oil accumulation. 74 SOLAS (1997)CH II-2 REG 18.6
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2024
Resolved
The following basic principles underlie the regulations in this chapter and are embodied in the regulations as appropriate, having regard to the type of ships and the potential fire hazard involved: restricted use of combustible material. The engine room was found to be housing active batteries in wood box fixtures. 74 SOLAS (1997)CH II-2 REG 2.2.3
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 November 2024
Resolved
Fire hoses shall be of non-perishable material approved by the Administration and shall be of sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. During testing of ships main fire pump PSCO observed one of the two hoses to have 100s of pin hole leaks throughout the length of the hose. 74 SOLAS (1997) CH II-2 REG 4.7.1
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 November 2024
Resolved
For ships constructed on or after 1 October 1994, the alternative means to be provided in accordance with the provisions of paragraph 3.3.3 shall be an independently driven, power operated emergency fire pump with its source of power and sea connection located outside the machinery space. PSCO observed vessel has no emergency fire pump on board to test. 74 SOLAS (1997)CH II-2 REG 4.3.3.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 November 2024
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. There was exposed electrical wiring present in the engine room. 74 SOLAS (2004)CH II-1 REG 45.1.3
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 25 November 2024
Resolved
Machinery spaces of category A shall be adequately ventilated so as to ensure that when machinery or boilers therein are operated at full power in all weather conditions including heavy weather , an adequate supply of air is maintained to the spaces for the safety and comfort of personal and the operation of machinery. PSCO observed a fan identified by crew as the engine room ventilation fan had been electrically disconnected and not operational. 74 SOLAS (2004)CH II-1 REG 35
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2024
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84). When directed to energize navigational lighting PSCO observed multiple navigation lights were not energized. 33 CFR 83.22(b)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 November 2024
Resolved
Passenger ships of less than 500 gross tonnage where the total number of persons on board is less than 200 may comply with the following: They shall carry on each side of the ship inflatable or rigid liferafts of such aggregate capacity as to accommodate the total number of person on board. Unless arrangements allow for easy side to side transfer, additional liferafts shall be provided so that the total capacity available on each side shall accommodate 150% of total number of persons onboard. The PSCO observed that the vessel was issued a Passenger Ship Safety Certificate back in May of 2024 which authorized the carriage of 100 adult passengers and 20 child passengers, and a minimum safe manning document requiring a crew of 10 . However, the vessel only has two 25 person liferafts, one on port and one on starboard. 74 SOLAS (1997)CH III REG 20.1.5
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 November 2024
No resolution recorded
Fixed fire detection and fire alarm systems for periodically unattended machinery spaces. PSCO found the vessels installed fixed fire detection system in the engine room was not operational. The vessel has installed two household style smoke detectors above each main engine. 74 SOLAS (1997)CH II-2 REG 14.1-.3
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 November 2024
Resolved
Machinery spaces of category A containing internal combustion machinery shall be provided with: One of the fire-extinguishing systems required by paragraph 1.1. After review of service certificates for the ships fixed fire extinguishing system PSCO discovered the findings from servicing companies 12SEP2024 report as follows: Cylinders 3 years overdue for hydrotest, Cylinders Low in CO2/Empty and are currently ineffective, hoses not replaced at 10 years and are showing damage and need replaced, alarm switch has been removed and should be reconnected, pin to hold center valve actuator in place is missing and needs to be replaced, blow through of manifold, distribution valve test not completed as no air compressor available on board. During visual inspection of system and piping PSCO observed heavy corrosion to system and piping. 74 SOLAS (1997)CH II-2 REG 7.2.1
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 November 2024
No resolution recorded
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed crew attempting to operate all five remote fuel shut offs all five failed to operate. 74 SOLAS (1997)CH II-2 REG 15.2.5
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. During inspection in the vessels engine room PSCO’s carbon monoxide detector alarmed alerting to detectable presence of Carbon Monoxide, additionally PSCO observed a cloudy haze in engine room, and identified the distinct smell of engine exhaust, suggesting a significant exhaust leak.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 November 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. During inspection in the vessels engine room PSCO’s carbon monoxide detector alarmed alerting to detectable presence of Carbon Monoxide, additionally PSCO observed a cloudy haze in engine room, and identified the distinct smell of engine exhaust, suggesting a significant exhaust leak. 74 SOLAS (2004)CH I REG 11
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 November 2024
No resolution recorded
For ships constructed on or after 1 October 1994, the alternative means to be provided in accordance with the provisions of paragraph 3.3.3 shall be an independently driven, power operated emergency fire pump with its source of power and sea connection located outside the machinery space. PSCO observed vessel has no emergency fire pump on board to test. 74 SOLAS (1997)CH II-2 REG 4.3.3.1
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2024
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84). When directed to energize navigational lighting PSCO observed multiple navigation lights were not energized. 33 CFR 83.22(b)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 November 2024
No resolution recorded
Passenger ships of less than 500 gross tonnage where the total number of persons on board is less than 200 may comply with the following: They shall carry on each side of the ship inflatable or rigid liferafts of such aggregate capacity as to accommodate the total number of person on board. Unless arrangements allow for easy side to side transfer, additional liferafts shall be provided so that the total capacity available on each side shall accommodate 150% of total number of persons onboard. The PSCO observed that the vessel was issued a Passenger Ship Safety Certificate back in May of 2024 which authorized the carriage of 100 adult passengers and 20 child passengers, and a minimum safe manning document requiring a crew of 10 . However, the vessel only has two 25 person liferafts, one on port and one on starboard. 74 SOLAS (1997)CH III REG 20.1.5
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2024
Resolved
Any required fire detectionshall be capable of immediate operation at all times. Smoke alarm shall be operational located on the bridge.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2024
Resolved
Bilge wells in periodically unattended machinery spaces shall be monitored in such a way that the accumulation of liquids is detected at normal angles of trim and heel. High water level float switch found to be inoperable.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 November 2022
Resolved
A self-propelled vessel of 65 feet or more in length, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS Class A device.
An AIS is not installed on board. Clear NLT 60dayS
33CFR164.46(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2022
Resolved
Main and Emergency switchboards shall be so arranged as to give access without danger to personnel. Nonconducting mats or grating shall be provided at the front of the switchboard.
vessel switchboard has missing plugs on front of switchboard that may expose crew to electrical shock. A nonconducting mat is not installed infront of the switchboard.
74SOLAS(04)II-1/45.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2022
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
The light cover in the galley is missing, causing exposed wires and light element.
74SOLAS(04)II-1/45.1.3
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 November 2022
Resolved
Each vessel must have Marine charts of the area to be transited, published by the National Ocean Service, U.S. Army Corps of Engineers, or a river authority that Are of a large enough scale and have enough detail to make safe navigation of the area possible and Are currently corrected.
33CFR164.33(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 November 2022
Resolved
The fitting of effective screens, to prevent the oil fuel in the case of spillage through the terminations of the sounding pipes from coming into contact with a source of ignition.
Starboard side fuel oil vent flame screen is functional due to corrosion.
74SOLAS(97)II-2/15.2.6.1.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 November 2022
No resolution recorded
The machinery...shall be designed and constructed adequate for the service which they are intended and shall be installed and protected as to reduce to a minimum any danger to persons on board.
#1 Ship Generator's temperature and oil gauges are not working; turbo intake hose to manifold is saturated with oil; and missing valve cover breather.
74SOLAS(04)II-1/26.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 15 November 2022
Resolved
Water tight decks, trunks, tunnels...shall be of the same strength, as watertight bulkheads.
Port side deck trunk and Steering trunk's hatch gaskets are not properly sealing.
74SOLAS(04)II-1/19.1
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 July 2020
Resolved
Found vessels loadline painted over and not contrasting in color. The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background. They shall also be permanently marked on the sides of the vessels to the satisfaction of the assigning authority.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 July 2020
Resolved
Every part of the crew accommodation, except store rooms, shall be kept free from stores and other property not belonging to or provided for the use of persons for whom that part of the accommodation is appropriated, and in particular no cargo shall be kept in any part of the crew
accommodation.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 30 July 2020
Resolved
Main deck Port Stern quarter railing missing middle rail
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 July 2020
Resolved
Provide coast pilot, light list, Nav rules.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 30 July 2020
Resolved
Provide onboard signalling lamp
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 July 2020
Resolved
Provide 2 additional parachute flares for a total of 12.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2020
Resolved
Provide nozzels for 2 fire hose stations in engine room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2020
Resolved
Provide nozzle for port side fire hose station on deck
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 30 July 2020
Resolved
Post Marpol Placard in common area.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2020
Resolved
Provide Y applicator for each nozzle fire station in engine room
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 July 2020
Resolved
Offload oilywater in machinery space to an approved reception facility.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 July 2020
Resolved
Make repairs to water tight door coamings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 July 2020
Resolved
Provide dogs for dampers and dead light covers.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 July 2020
Resolved
Main fuel shutoff operational remote shut offs require maintenance.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 21 July 2017
Resolved
Control of oil discharge. Repair/replace sight glass valves for daily fuel tank. Engineer stated that vessel's sight glass valve is showing improper level due to faulty valve. Engineer used a wire-tie strap to keep valve open.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 21 July 2017
Resolved
Remove fuel-oil from engine room bilge. Vessel's engine room bilge had approximately 10 gallons of oil/fuel.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 21 July 2017
Resolved
Remove all fuel oil soaked contaminants from vessel.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 21 July 2017
Resolved
Vessels wood planks located on main deck are soaked with fuel. Vessel need to remove oil soaked planks from vessel and replace.
Deck/Cargo › Cargo Stowage › General
Issued 15 August 2016
Resolved
The vessel's cargo loading door gasket is 4 inches short from top of the seal. Vessel must replace this missing edge of the gasket.
Communications › Radio Communications › EPIRB
Issued 9 March 2016
Resolved
Satellite EPIRB must comply with performance standards. EPIRB is not registered with the vessel's admin and does not transmit vessel data when energized.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Master
Issued 9 March 2016
Resolved
The master and chief mate shall have the minimum knowledge, understanding and proficiency, required for the certification they currently hold, listed in STCW code Part A, column 2 of table A-II/2. FOTU O SAMOA II crew members do not have appropriate STCW training for carriage of dangerous goods in packaged form.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 9 March 2016
Resolved
A ship of 100 GT or more must have containment capacity around each fuel vent or fuel fill pipe that has a capacity of at least 21 gallons; or equip each fuel vent or fuel fill pipe with a portable container of at least 5 U.S. gallon capacity when fueling.
Fire Fighting › Fire Hoses › Condition
Issued 9 March 2016
Resolved
Every ship shall be provided with fire hoses complying with applicable requirements in SOLAS Ch. II-2. One fire hose on the upper deck is missing a spray nozzle.
Stability › Weathertight Integrity › General
Issued 9 March 2016
Resolved
The cargo loading ramp gasket was found in a wasted condition. A four inch long section of gasket was found severed and a ten inch section of gasket is warped which prevents a weathertight seal.
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 9 March 2016
Resolved
At least two self contained breathing apparatuses additional to those required by SOLAS Ch. II-2 regulation 17 shall be provided for carriage of dangerous goods. FOTU O SAMOA only maintains two SCBAs onboard for fire fighting purposes.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 August 2015
Resolved
A life jacket complying with the requirements of the Code shall be provided for every person on board the ship. There were no adequate life jackets for all crew members on board. 74 SOLAS 09 III/2.1
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 4 August 2015
Resolved
Rescue boat shall be in a state of continuous readiness for launching and in a position suitable for launching and recovery. Rescue boat launching arrangements unable to maneuver freely making the launching of the rescue boat inefficient and dangerous to crew members. 74 SOLAS 01 III/14
Lifesaving › Rocket Parachute Flares › General
Issued 4 August 2015
Resolved
Not less than 12 rocket parachute flares shall be carried and stowed on or near the bridge. Vessel only had 02 smoke signal, 04 hand flares, and 03 parachute flares on board. 74 SOLAS 09 III/6.3
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 4 August 2015
Resolved
A line-throwing appliance complying with the requirement of section 7.1 of the Code shall be provided. It should include no less than 4 projectiles and four lines. There are no line-throwing appliances on board the vessel. 74 SOLAS 09 III / 18
Fire Fighting › Fire Pumps › Pressure
Issued 4 August 2015
Resolved
Emergency fire pump shall be independent riven with its source of power and sea connection located outside the machinery space. Portable fire pump serving as emergency fire pump of vessel could not provide satisfactory water pressure. 74 SOLAS 01 II-2 / 4.3.3.3.1
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 4 August 2015
Resolved
Ships shall carry at least two fireman's outfits complying with the requirements of paragraph one. All fireman outfits on board the vessel were in a state of disrepair. 74 SOLAS 01 II-2 / 17.3
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 4 August 2015
Resolved
Any required automatic fire detection and fire alarm system shall be capable of immediate operation at all times. All smoke detectors in bridge area were inoperable. 74 SOLAS 01 II-2 / 12.1.1
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 4 August 2015
Resolved
Vessel must have a fixed containment under or around tank vent overflow and fill pipe to comply with regulation 33 CFR 155.320 (b)
Documentation › Certificates/Documents › Document of Compliance (dangerous goods)
Issued 4 August 2015
Resolved
The administration shall provide the ship with appropriate document as evidence of compliance of construction and equipment with the requirements of this regulation. Vessel does not have a Document of Compliance for the Carriage of Dangerous Goods. 74 SOLAS 09 II-2 / 54.3
Deck/Cargo › Cargo Stowage › General
Issued 4 August 2015
Resolved
Vessels carrying dangerous goods shall comply with table 54.1 of Reg. 54. 74 SOLAS 01 II-2 / 54.3
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 4 August 2015
Resolved
To ensure the safe operation of each ship and to provide a link between the Company and those on board, every company should designate a person or persons ashore having direct access to the highest level of management. There is no one designated as a DPA or contact information for that person in the vessel's SMS manual. 74 SOLAS 09 IX/3.1, ISM Code 4
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 4 August 2015
Resolved
The company should ensure that the master is: fully conversant with the Company's safety management system. The master stated that he was familiar with the ISM Code and SMS principles; however, when asked questions pertaining to the SMS, he was not competent with critical sections and was unable to clearly articulate the requirements of the vessel's SMS. ISM Code 6.1.2
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 4 August 2015
Resolved
The Company should ensure that all personnel involved in the Compay's safety management system have an adequate understanding .... Vessel's officers were not familiar with SMS procedures and guidelines to include unfamiliarity of submission of Non-Conformity reports, lack of knowledge of monthly maintenance inspections, and critical sections of he vessel's SMS. ISM Code 6.4
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 4 August 2015
Resolved
Non-Conformities, accidents and HAzardous conditions: Vessel does not have any adequate life jackets for crew on board, all smoke detectors in bridge area are inoperable, portable emergency fire pump cannot provide adequate pressure, and all fireman outfits on board the vessel are in state of disrepair, ; however, no non-conformity reports were made to the company. ISM Code 9.1
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 4 August 2015
Resolved
Procedures, to ensure that the ship is maintained in conformity with relevant rules and regulations: The ship’s maintenance checklists do not include weekly tests and inspections of survival craft and launching appliances, an inspection required by SOLAS, and there is no record of any lifesaving appliance inspections having taken place. Also, last monthly inspection was conducted on 28AUG14
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 4 August 2015
Resolved
The company should establish procedures, to ensure that the ship is maintained in conformity with relevant rules and regulations. In meeting these requirements, the company should ensure that any non-conformity is reported with its possible cause. Vessel's crew have not submitted any non-conformity reports to the company for action to be taken. ISM Code 10.2.2
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 4 August 2015
Resolved
Establish procedures, to ensure that the ship is maintained in conformity with relevant rules and regulations.There are no records on board the vessels of non-conformity reports being submitted, of quarterly inspection conducted by Maritime surveyor as per SMS manual, of yearly inspections by ACEO Maritime as per SMS manual, and last record of monthly inspection is from 20AUG14. ISM Code 10.2.4
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 4 August 2015
Resolved
The company should carry out internal safety audits on board and ashore at intervals not exceeding 12 month to verify whether safety and pollution-prevention activities comply with the safety management system. Upon request, the vessel captain could not provide proof of when the last company internal audit was completed. ISM Code 12.1
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 4 August 2015
Resolved
Company shall ensure that seafarers, on being assigned to any of their ships, are familiarized with their specific duties. No crew members on board received crew familiarization training upon reporting on board vessel. STCW 2010 Amend Reg I/4.2.4 and I/14.5
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 4 August 2015
Resolved
The Passenger Ship Safety Certificate (PSSC), the Cargo Ship Safety Equipment Certificate (CSSEC), and the Cargo Ship Safety Radio Certificate (CSSRC) shall be supplemented by a Record of Equipment. Vessel's PSSC, CSSEC, and CSSRC are not supplemented by a Record of Equipment. 74 SOLAS 09 I/12 (a)(vi)
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 4 August 2015
Resolved
The certificates and records of equipment shall be drawn up in the form corresponding to the models given in the appendix to the present Convention. Vessel's PSSC, CSSEC, and CSSRC are not drawn up in accordance with corresponding models. 74 SOLAS 09 I/15
Documentation › Certificates/Documents › IOPP Certificate
Issued 4 August 2015
Resolved
The International Oil Pollution Prevention (IOPP) Certificate shall be drawn up in the form corresponding to the model given in appendix II. Vessel's IOPP Certificate not drawn up in accordance with corresponding model and missing required supplemented Record of Equipment. MARPOL ANNEX I Ch. 2 / Reg. 9
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 4 August 2015
Resolved
The International Air Pollution Prevention (IAPP) Certificate shall be drawn up in a form corresponding to the model given in appendix I. Vessel's IAPP Certificate not drawn up in accordance with corresponding model and missing required supplemented Record of Equipment. MARPOL ANNEX VI Ch. 2 / reg. 8
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 4 August 2015
Resolved
The form of the International Tonnage Certificate shall correspond to that of the model given in Annex II. Vessel's International Tonnage Certificate is missing reverse of certificate. ITC, 1969 Article 9
Documentation › Certificates/Documents › International Load Line Certificate
Issued 4 August 2015
Resolved
The International Load Line Certificate (ILLC) shall be drawn up in the form corresponding to the models given in Annex III to the present Convention. The vessels ILLC in accordance with the corresponding form It is missing the "Date of initial or periodical survey" and pages for endorsement of surveys. LOAD LINES Article 18
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 21 June 2012
Resolved
Portable fire extinguisher in engine found in unservicable condition
Lifesaving › Inflatable Liferafts › Servicing
Issued 21 June 2012
Resolved
The vessel's life rafts were well overdue for servicing
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 June 2012
Resolved
Vessel either had missing or outdated publications.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 January 2010
Resolved
Found vessel operating with additional personnel on board with no additional PFD's
Lifesaving › Inflatable Liferafts › Capacity
Issued 28 January 2010
Resolved
Found vessel operating above capacity of life rafts. Provide additional life raft to meet capacity of crew and passnegers
Fire Fighting › Portable Foam Applicators › General
Issued 24 September 2007
Resolved
No four foot applicators for each fire nozzle in the engine room.
Fire Fighting › International Shore Connection › Not on Board
Issued 24 September 2007
Resolved
Missing international shore connection.
Fire Fighting › Fire Hydrants › Condition
Issued 24 September 2007
Resolved
Fire main stations on deck are not uniform in design.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 24 September 2007
Resolved
Vessel missing the proper number of fire axes (4 required).
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 September 2007
Resolved
STBD Generator load management not possible due to previous fire in switchboard. Components were distroyed in fire.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 24 September 2007
Resolved
Anchor strap on STBD side brake is wasted.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 September 2007
Resolved
Vessel is required to have bilge slops piping outlet on deck with stop valve and a means to stop each pump on deck near discharge. Outlet must meet the requirments of 33CFR155.430
Documentation › Markings/Placards › Oil Discharge Placard
Issued 24 September 2007
Resolved
Discharge of oil prohibited placards are not posted as required.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 September 2007
Resolved
Port side anchor ladder railing is wasted at top.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 24 September 2007
Resolved
No waste management plan on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 September 2007
Resolved
Vessels nav lights are in need of repair as indicated by a missing globe and a garbage bag used to protect light from rain and several spare bulbs failed to illuminate.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 24 September 2007
Resolved
Navigation light indicator pannel is not fully operational as indicated when lamp test failed to illuminate all lamps.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 24 September 2007
Resolved
Hydrostatic release is not marked for expiration on 25 man liferaft.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 24 September 2007
Resolved
Vessel is not equiped with a sewage treatment tank/holding tank. Remove toilets or install type I, II, III sanitation device.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.