Records from 2016 to 2026. Most recent: inspection, 8 July 2026.
Documentation record
Registered dimensions (L × B × D)34.0 ft × 12.0 ft × 4.3 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRANT'S FIBERGLASSING INC · MIAMI, FL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portBOKEELIA, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 20 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
8 July 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8440024
23 September 2025
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8238636
3 July 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7947181
4 June 2024
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7926012
26 October 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7814215
13 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576893
21 September 2022
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7562899
5 October 2021
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7326243
8 December 2020
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7108113
19 October 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7076408
29 July 2020
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7013220
29 May 2019
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6698019
27 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6548919
9 July 2018
Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6469524
5 October 2017
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6280396
28 September 2016
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6010382
5 July 2016
Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5917441
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Identified multiple unsatisfactory condition life jackets on board the vessel. Currently 05 satisfactory adult size life jackets are on board the vessel. Vessel needs 16 additional adult size life jackets to meet the required life saving equipment IAW the approved COI.
The vessel is limited to no more than 03 passengers + 2 crew until corrected.
46CFR180.71
Action required: 705 - Other - as specified
Resolved 14 November 2025
Resolution: Vessel replaced 16 adult size life jackets, and now has total number of life jackets required by the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2025
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter.
The ring life buoy on board the vessel is in unsatisfactory condition, due to wear. Replace the ring life buoy.
46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
Resolution: Vessel replaced and properly labeled the ring life buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 June 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
ID'd the following unsafe conditions: Port fuel compartment vent fan wiring not secured, fuel compartment vent closure labels excessively worn and not legible, forward port vent closure device pin is seized, ladder to forward compartment not secure, grab rail on top of pilothouse not secure.
Correct above items to the satisfaction of the attending CG Marine Inspector.
46CFR176.830
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2024
Resolved 2 July 2024
Resolution: Port fuel compartment vent fan wiring now secured, fuel compartment vent closure labels renewed, forward port vent closure device pin no longer seized, ladder to forward compartment now stable, grab rail on top of pilothouse now secure.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 July 2020
Resolved
Repair affected areas of hull and through hull bolts IWO splash rail on port side. Damaged and separated splash rail measured from bow 15' to 20' 6''. Failure of bolts for splash rail evident by corrosion and seepage of resin in port void spaces. Submit repair plan and make permanent repairs to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 3 August 2020
Resolution: New splash rail installed. Affected area reglassed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 May 2019
Resolved
Bilge high water alarm audible alarm is inoperable; replace to manufacturer specification prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 9 July 2019
Resolution: Alarm replaced with new and demonstrated to operate.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 September 2016
Resolved
Two portable battery lights (flashlights)were not provided onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 November 2016
Resolution: provided two operational flashlights
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 September 2016
Resolved
Quarterly "man over board", abandon vessel and fire drills were not conducted and logged
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 28 September 2016
Resolution: During the inspection drills were conducted and logged, this deficiency was corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 September 2016
Resolved
Lifejackets stowage was not marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 November 2016
Resolution: Marked stowage for lifejackets
Navigation › Piloting/Steering › Marine Charts
Issued 28 September 2016
Resolved
Current and approved charts were no carried onboard the vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 November 2016
Resolution: purchased new chart