ISLAND GIRL IV

ISLAND GIRL IV is a 2004 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2004, most recently in July 2026, along with 23 deficiencies.

Records from 2004 to 2026. Most recent: inspection, 8 July 2026.

Built
2004
Last inspected
8 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP7071
702179
Flag
UNITED STATES
—
Maury page id
psix-702179

Inspections, by type

Years with a record 18 calendar years (2004–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.0 ft × 12.0 ft × 4.3 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRANT'S FIBERGLASSING INC · MIAMI, FL, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portBOKEELIA, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 11 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

8 July 2026 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8440024
23 September 2025 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8238636
3 July 2024 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7947181
4 June 2024 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7926012
26 October 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7814215
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576893
21 September 2022 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7562899
5 October 2021 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7326243
8 December 2020 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7108113
19 October 2020 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7076408
29 July 2020 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7013220
29 May 2019 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6698019
27 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6548919
9 July 2018 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6469524
5 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6280396
28 September 2016 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6010382
5 July 2016 Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5917441
28 October 2015 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5750752
12 June 2012 Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4340832
11 January 2012 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4222149
2 September 2011 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4133914
26 January 2011 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3929162
19 November 2008 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3362164
18 June 2008 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3238899
15 January 2008 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3114207
11 January 2007 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2854003
27 June 2006 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2689343
22 February 2006 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2589302
9 February 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2582461
8 December 2004 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2255702
30 November 2004 Initial Certification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2250213
2 August 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2153796
16 July 2004 Simplified Stability Test · Construction Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2135356

Deficiency record · 23

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Identified multiple unsatisfactory condition life jackets on board the vessel. Currently 05 satisfactory adult size life jackets are on board the vessel. Vessel needs 16 additional adult size life jackets to meet the required life saving equipment IAW the approved COI. The vessel is limited to no more than 03 passengers + 2 crew until corrected. 46CFR180.71
Action required: 705 - Other - as specified
Resolved 14 November 2025
Resolution: Vessel replaced 16 adult size life jackets, and now has total number of life jackets required by the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2025 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. The ring life buoy on board the vessel is in unsatisfactory condition, due to wear. Replace the ring life buoy. 46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
Resolution: Vessel replaced and properly labeled the ring life buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. ID'd the following unsafe conditions: Port fuel compartment vent fan wiring not secured, fuel compartment vent closure labels excessively worn and not legible, forward port vent closure device pin is seized, ladder to forward compartment not secure, grab rail on top of pilothouse not secure. Correct above items to the satisfaction of the attending CG Marine Inspector. 46CFR176.830
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2024
Resolved 2 July 2024
Resolution: Port fuel compartment vent fan wiring now secured, fuel compartment vent closure labels renewed, forward port vent closure device pin no longer seized, ladder to forward compartment now stable, grab rail on top of pilothouse now secure.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 July 2020 Resolved
Repair affected areas of hull and through hull bolts IWO splash rail on port side. Damaged and separated splash rail measured from bow 15' to 20' 6''. Failure of bolts for splash rail evident by corrosion and seepage of resin in port void spaces. Submit repair plan and make permanent repairs to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 3 August 2020
Resolution: New splash rail installed. Affected area reglassed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 May 2019 Resolved
Bilge high water alarm audible alarm is inoperable; replace to manufacturer specification prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2019
Resolved 9 July 2019
Resolution: Alarm replaced with new and demonstrated to operate.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 September 2016 Resolved
Two portable battery lights (flashlights)were not provided onboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 November 2016
Resolution: provided two operational flashlights
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 September 2016 Resolved
Quarterly "man over board", abandon vessel and fire drills were not conducted and logged
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 28 September 2016
Resolution: During the inspection drills were conducted and logged, this deficiency was corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 September 2016 Resolved
Lifejackets stowage was not marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 November 2016
Resolution: Marked stowage for lifejackets
Navigation › Piloting/Steering › Marine Charts
Issued 28 September 2016 Resolved
Current and approved charts were no carried onboard the vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2016
Resolved 4 November 2016
Resolution: purchased new chart
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 28 October 2015 Resolved
The flammable vapor detection system operats but sytem audible alarm is inoperative. Repair/replace unit at operating station. 46 CFR 182.480
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2015
Resolved 10 November 2015
Resolution: Replaced audible unit at operating station. Conducted operational test, test SAT.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 12 June 2012 Resolved
Repair/Replace the vapor detector in the fuel tank void IAW 46 CFR 182.480.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Navigation › Piloting/Steering › Marine Charts
Issued 26 January 2011 Resolved
Provide up to date charts of area navigated.
Due 8 February 2011
Resolved 2 February 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 January 2011 Resolved
Provide the proper amount of asprin and eyewash for the first aid kit.
Due 8 February 2011
Resolved 5 February 2011
Engineering › Bilge Water Management System › Not Operational
Issued 19 November 2008 Resolved
Make permanent reparis to the audible high water alarm
Action required: 705 - Other - as specified
Due 21 November 2008
Resolved 23 December 2008
Resolution: Cleared
Communications › Audible Communications › Horn/Whistle
Issued 19 November 2008 Resolved
Make repairs to audible horn.
Action required: 705 - Other - as specified
Due 21 November 2008
Resolved 21 November 2008
Resolution: Cleared
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 November 2004 Resolved
Segregate adult and children PFDs and label stowage areas.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 16 February 2005
Engineering › Fuel Oil Service System › Valve
Issued 30 November 2004 Resolved
Label fuel shutoff valve at fuel filter.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 16 February 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 November 2004 Resolved
Fax current contract for chemical testing program to MSD Ft. Myers
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 16 February 2005
Communications › Audible Communications › Bell
Issued 30 November 2004 Resolved
Provide bell for vessel.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 16 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 November 2004 Resolved
Provide proper running light installation on portside of vessel.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 4 January 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 November 2004 Resolved
Conduct at least 3 man-overboard recovery drills and fax log entries to MSD FT Myers.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 4 January 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 November 2004 Resolved
Install permanent fasteners on batteries.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 16 February 2005
Documentation › Certificates/Documents › Stability Letter
Issued 30 November 2004 Resolved
Fax copy of stability letter to MSD FT Myers.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 30 November 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.