MAURY USCG vessel records Sign in
← All vessels

PAUL HERRON

PAUL HERRON is a 1972 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 1999, most recently in August 2003, along with 30 deficiencies.

Records from 1999 to 2003. Most recent: inspection, 1 August 2003.

Built
1972
Last inspected
1 August 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-7022

Inspections, by type

Years with a record 5 calendar years (1999–2003)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it8 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

1 August 2003 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1941784
26 June 2003 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1941236
27 June 2002 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1639573
22 June 2001 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1067744
8 August 2000 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1389199
14 June 2000 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 819248
26 July 1999 Initial Certification · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1406712

Deficiency record · 30

Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 26 June 2003 Resolved
Service portable fire extinguishers. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Service
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certified service.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 June 2003 Resolved
Install CO2 bottle for fixed firefighting system. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Tanks
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Fire Fighting › Miscellaneous Items
Issued 26 June 2003 Resolved
Submit report of servicing for fixed firefighting system to include heat activated device, alarm, pressure switch and line blow down. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Servicing
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Lifesaving › Buoyant Apparatus
Issued 26 June 2003 Resolved
Install inflatable buoyant apparatus. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: missing
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Lifesaving › Visual Distress Signals (General)
Issued 26 June 2003 Resolved
Provide distress signals. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Quantity
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 June 2003 Resolved
Demonstrate operation of main engine, controls, and gauges. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Controls
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Documentation › Certificates/Documents
Issued 26 June 2003 Resolved
Provide valid State Registration. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Stae Registration
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Fire Fighting › Emergency Fire Pumps
Issued 26 June 2003 Resolved
Provide 2-1/2 gallon fire buckets with 6' lanyard attached to handle and labeled "FIRE BUCKET". This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Fire Buckets
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Communications › Radio Communications
Issued 26 June 2003 Resolved
Install and demonstrate operation of Motorola Radio. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Electrical › Lighting (emergency)
Issued 26 June 2003 Resolved
Provide flashlight. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Accommodation/Occupational Safety › Medical/First Aid
Issued 26 June 2003 Resolved
Provide first aid kit. This item must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Medicine Chest
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Construction/Loadline › Hull
Issued 26 June 2003 Resolved
Crop and renew as original #2 plank port side, 17 feet aft of the stem where split between butt block and frame. Vessel may not carry passengers until this item is completed. Vessel may be used as a standby rescue vessel only, when all other requirements listed under this activity are cleared. LEGACY COMPONENT DESC: Bottom Plating
Due 26 July 2003
Resolved 1 August 2003
Resolution: Vessel no longer in certificated service.
Lifesaving
Issued 22 June 2001 Resolved
Provide orange smoke signals in accordance with 46 CFR 180.68. Requirementto be completed prior to the carriage of passengers._x001C_
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Lifesaving
Issued 22 June 2001 Resolved
Properly install inflatable buoyant apparatus in accordance with 46CFR180.130 prior to the carriage of passengers.
Condition: Unknown
Due 3 July 2001
Resolved 3 July 2001
Engineering
Issued 22 June 2001 Resolved
Label port and stbd fuel shut off valves in accordance with 46 CFR 185.608.Requirement to be completed prior to the carriage of passengers.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Construction/Loadline
Issued 8 August 2000 Resolved
Provide auto bilge visual indication at the operating station.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Lifesaving
Issued 8 August 2000 Resolved
Attach IBA painter to hydrostatic release weak link.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Construction/Loadline
Issued 8 August 2000 Resolved
Provide check valve for all bilge overboards.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Construction/Loadline
Issued 8 August 2000 Resolved
Remove rot and replace wasted area of #4 floor timber at fwd keel area.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Engineering
Issued 8 August 2000 Resolved
Replace all vital system flexible hose with SAE/F 1942 or USCG approved A1,A2, B1, B2 hose._x001C_
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Fire Fighting
Issued 8 August 2000 Resolved
Mount aft extinguisher.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Engineering
Issued 8 August 2000 Resolved
Label F.O. shut off valve on/off positions.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Construction/Loadline
Issued 26 July 1999 Resolved
LENGTHEN SHORT (3.5/4.5 FT) STARBOARD SIDE FRAMES OUTBOARD FROM KEEL.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Construction/Loadline
Issued 26 July 1999 Resolved
REPAIR/REPLACE LAZARETTE STARBOARD OUTBOARD BOTTOM BATTONS ALL CHECKED.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Lifesaving
Issued 26 July 1999 Resolved
FOUND LIFEJACKETS AND LIFE RINGS MISSING REFLECTIVE TAPE (CG-835).
Condition: Unknown
Due 20 August 1999
Resolved 9 May 2000
Fire Fighting
Issued 26 July 1999 Resolved
PROVIDE ANNUAL SERVICING/INSPECTION FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 20 August 1999
Resolved 9 May 2000
Fire Fighting
Issued 26 July 1999 Resolved
PROVIDE ENGINE SPACE SMOKE TIGHT FOR FIXED FIRE FIGHTING SYSTEM, AREA AROUND GUNNEL EXPOSED TO ATMOSPHERE (CG-835).
Condition: Unknown
Due 20 August 1999
Resolved 9 May 2000
Engineering
Issued 26 July 1999 Resolved
PROVIDE GAS ENGINES MISSING BLOWER INTERLOCK (CG-835).
Condition: Unknown
Due 20 August 1999
Resolved 9 May 2000
Construction/Loadline
Issued 26 July 1999 Resolved
NUMBER 4 PORT FORWARD FRAME SLIGHT WET ROT AT BATTONS AND NUMBER 2 PORT AFTFRAME; WET ROT AT BOTTOM FROM FLOOR TIMBER.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Fire Fighting
Issued 26 July 1999 Resolved
PROVIDE 3 FIRE BUCKETS WITH LANYARD.
Condition: Unknown
Due 20 August 1999
Resolved 10 May 2000

Ownership record