← All vessels
HERO
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named HERO
HERO is a 2000 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in May 2026, along with 8 deficiencies and 1 casualty investigation in 2024.
Records from 2016 to 2026. Most recent: inspection, 20 May 2026.
- Built
- 2000
- Last inspected
- 20 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2024
Identity
1096726
WDK6793
7025
Flag
UNITED STATES
368078150
Maury page id
psix-7025
Inspections, by type
…with no type recorded2
Years with a record
9 calendar years (2016–2026)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)44.3 ft × 13.4 ft × 6.3 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHE TALARIA COMPANY · SOUTHWEST HARBOR, ME, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portWATCH HILL, RI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK6793MMSI 368078150 · active · compulsorily equipped · granted 26 February 2019, expires 26 February 2029
WCZ9704MMSI 366787050 · expired · voluntarily equipped · granted 3 August 2000, cancelled 9 October 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 19
20 May 2026
In-Service Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8370664
1 December 2025
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8269943
27 May 2025
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8140738
16 May 2024
Hull Examination · Damage Survey · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7913657
14 May 2024
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7914022
6 September 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7696102
7 February 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7633140
5 October 2022
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7572117
6 June 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7470101
16 November 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7351950
1 October 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7324528
25 May 2021
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7206126
24 May 2021
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7194161
19 March 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7150114
8 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999281
12 December 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6870168
30 July 2019
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6767356
7 May 2019
Administrative Inspection · Hull Examination · Initial Certification · Simplified Stability Test · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6683392
27 May 2016
Type not recorded
No type recorded · Station Annapolis · USCG East District (CGD-E) · Activity 5892156
Deficiency record · 8
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2021
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. No donning instructions were posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2021
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of 46 CFR 181.500 must be designed, constructed, installed and maintained in accordance with a recognized industry standard acceptable to the Commandant. Extra fire extinguisher under seat at main council was not labeled as being stored behind the door and was not in approved bracket as required by manufacturer.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 May 2021
Resolved
Each small battery installation must be from falling objects. A small battery installation must not be in a closet, storeroom or similar space. The two batteries in the engine room space are not covered and are exposed to falling objects.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. The mid-space electric bilge pump located in the engine room was unable to operate.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 25 May 2021
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. During inspection, there was no securing or locking device on the valves leading overboard for the sewage discharge.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2019
Resolved
indicator for high level alarm was only visual and not audible for all compartments. Alarms shall be prepared for both visual and audible.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 December 2019
Resolved
Magnetic compass had no lumination. Repair light on compass.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 December 2019
Resolved
radio operator permit not on board with master. Provide proof of permit.
Casualty record · 1
14 May 2024Routine · role: Involved in a Marine Casualty · activity 7914022
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.