NOLA is a 2004 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in November 2025, along with 14 deficiencies and 1 casualty investigation in 2025.
Records from 2016 to 2025. Most recent: inspection, 13 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)52.0 ft × 16.7 ft × 7.3 ft
Registered tonnagegross 42 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBUILDING CORP · SOMERSET, MA, UNITED STATES · built 2004
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Simplified, Gross Ton 33 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
13 November 2025Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8034841
4 March 2025Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8098609
14 November 2024Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8034835
24 April 2024Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7900926
8 January 2024Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7846784
7 December 2023COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7834713
20 July 2023Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7671955
29 December 2022Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7604338
20 December 2021Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7360346
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2025Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected.
MI observed the sewage suction line connection to the through hull fitting in the forward port side engine room was leaking. Prior to final rectification, submit a remediation proposal to the attending Marine Inspector for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 18 December 2025
Resolution: Received satisfactory photographs from the vessel's captain rectifying the 01 open defieicncy; see documents.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 December 2023Resolved
Vessel described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI observed missing detector located within pilot house. Properly install fire detector within pilot house to meet regulations outlined above. 46 CFR 181.405(c), Code 16.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 19 December 2023
Resolution: New detector was installed and paired.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 December 2023Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Port dry exhaust piping routed through the steering compartment has exposed sections of the piping. 46 CFR 177.97, code 16.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 19 December 2023
Resolution: Exhaust lagging was tightened to close open gaps.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 7 December 2023Resolved
Means of escape: The two required means of escape must be widely separated and, if possible, at opposite ends or sides of the space to minimize the possibility of one incident blocking both escapes. Vessel has a secondary door in front of the FWD engine room door that is lockable only from the outside. 46 CFR 177.500(b), code 16.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 19 December 2023
Resolution: A magnet style latch was installed in lieu of a mechanical one.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 December 2022Resolved
Electrical equipment on a vessel must be installed and maintained. Two electrical junction boxes were observed without proper closure and one 110v outlet was found with missing cover and contaminated with oil. 46CFR183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2023
Resolved 12 January 2023
Resolution: Closure was added to junction box and oil was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 December 2022Resolved
A bilge suction must be fitted with a suitable strainer. Multiple suction points were found without strainer. 46CFR182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2023
Resolved 12 January 2023
Resolution: Vessel replaced all missing strainers.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 December 2022Resolved
Machinery spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors.
A hole was observed in the overhead above the #2MDE. 46CFR177.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2023
Resolved 12 January 2023
Resolution: The hole over the #2 MDE was filled in.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 December 2022Resolved
Each motor must have a nameplate attached to it containing the information required by Article 430 of NFPA 70. Generator did not have nameplate. 46CFR183.320(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2023
Resolved 12 January 2023
Resolution: Vessel rep had manufacture send in data sheet containing all info on nameplate. Now laminated and posted on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 December 2022Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI observed that the vessel only had one detector in the forward passenger space. Vessel is to install an interconnected fire detection system that covers each of the following spaces: lazarette, machinery space, forward passenger space, and wheelhouse. 46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2023
Resolved 12 January 2023
Resolution: Vessel purhcase and installed wireless interconnected fire detection system onboard the vessel in all respected spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 December 2022Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed the generator had multiple fuel leaks between the fuel pump and high pressure fuel lines. MI observed fuel pump replaced and satisfactory operation on the generator. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 29 December 2022
Resolution: MI observed the generator had multiple fuel leaks between the fuel pump and high pressure fuel lines. MI observed fuel pump replaced and satisfactory operation on the generator.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 December 2022Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Both of the onboard lifefloats were deteriorated beyond their service life. Both were replaced and installation was witnessed by MI. 46 CFR 180.175 (a)
Action required: 10 - Deficiency Rectified
Resolved 29 December 2022
Resolution: Both were replaced and installation was witnessed by MI
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of ABS Steel Vessel Rules, (<61 Meters), with the appropriate conversions from the ABS Aluminum Vessel Rules. There is an approximately 2' X 1' area of localized pitting on the hull plating next to the fuel tank as well as an approximately 2' x 1' area of localized pitting along the bottom on the port side of the vessel's fuel tank.
Submit repair plan and replace in kind or provide gauging report from a [name withheld] attesting to allowable wastage of the tank and surrounding hull plating at vessel's next dry dock.
46 CFR 177.300
705 C
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 15 July 2021
Resolution: Vessel made acceptable repairs to fuel tank and hull.
Vessel found to be operating without a valid COI. Anniversary date is 21AUG and vessel continued to operated after 21NOV18. Vessel to cease operations until new COI inspection has been completed and given a temporary COI. 46 CFR 176.502 60c
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 December 2018
Resolution: COI inspection conducted on 11DEC18 and vessel was issued a temporary COI. All sat.
Provide repair proposal for port side fore peak damage to include the collision bulkhead and engine room aft port side damage to Sector New Orleans Domestic Inspections prior to conducting repairs and carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2016
Resolved 2 February 2017
Resolution: Vessel made required repairs to vessel. Verified watertight integrity of welds using dye-pen testing, all satisfactory.
4 March 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8098609
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.