Records from 2016 to 2026. Most recent: inspection, 30 July 2026.
Inspection history · 19
30 July 2026
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8433941
7 July 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8172029
14 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8103788
4 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7927109
2 May 2023
COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7675878
24 April 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7674702
6 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7469732
3 May 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7186447
22 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7180555
18 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6955113
9 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6680097
1 April 2019
Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6653386
24 January 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6614614
16 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6571981
5 September 2018
In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6534293
28 August 2018
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6530036
9 May 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6408809
8 June 2017
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6207745
8 June 2016
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5905744
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 July 2025
Resolved
Marine employers involved in a marine casualty that likely is a MSI shall comply with 46CFR4.06. O/O has 01 alcohol test, COI requires a Captain and a Deckhand. Vessel is restricted to operating within 02 hours of a testing facility until an additional alcohol test is procurred and placed on the vessel. 46CFR185.212
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2025
Resolution: O/O purchased an additional alcohol test strip and placed onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 May 2021
Resolved
A vessel on a Lakes, bays and sounds route must carry three hand red flare distress signals approved in accordance with 46 CFR 160.021 and three hand orange smoke distress signals approved in accordance with 46 CFR 160.037. Any hand red flare distress signal approved in accordance with 46 CFR 160.021 can be substituted for the hand orange smoke distress signal. Vessel only has four hand red flare distress signals. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2021
Resolved 7 May 2021
Resolution: Recieved pictures of eight new red flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021
Resolved
Flexible nonmetallic hose may be used in fuel oil systems subject to the provisions of 46 CFR 182.720(e)(v). Fuel hose currently installed is not marked as USCG Type A1, A2, B1 or B2. 46 CFR 182.720
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2021
Resolved 7 May 2021
Resolution: Recieved pictures of newly installed USCG B1 hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021
Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. Both primer bulbs of the portable fuel system for the outboard engine have numerous cracks and are exhibiting signs of deterioration. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2021
Resolved 7 May 2021