Inspection history · 24
4 May 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7443877
13 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6539435
23 January 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6559602
21 November 2016
Industry Initiated Exam
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6047259
14 March 2016
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5832824
28 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5805095
20 August 2012
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4416875
21 May 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4315031
10 April 2012
Industry Initiated Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4284364
8 September 2011
Spot Check (Safety)
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4139570
19 August 2010
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3906932
5 March 2010
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3690281
12 January 2010
Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3662460
13 May 2009
MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3474304
20 November 2008
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3366649
4 June 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3227273
19 March 2008
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3168743
23 March 2007
Type not recorded
No type recorded · USCG Great Lakes District (dpb) · USCG Great Lakes District (CGD-GL) · Activity 2893729
1 January 2007
Type not recorded
No type recorded · USCG Great Lakes District (dpb) · USCG Great Lakes District (CGD-GL) · Activity 2893664
27 February 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2592827
24 January 2006
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2574768
31 October 2004
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2262340
24 April 2002
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1609134
9 April 2002
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1607189
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018
No resolution recorded
Vsl is broadcasting: MMSI from expired FCC License, Call Sign from expired FCC License, no static draft information, and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 October 2018 — due date passed with no resolution recorded
Documentation › Certificates/Documents › FCC SSL
Issued 19 March 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 19 March 2008
Resolved
Pre sail checklist needed for March 2008 as required under 33 CFR 164
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Pre Sail Checklist now being completed.
Documentation › Certificates/Documents › FCC SSL
Issued 19 March 2008
Resolved
Great Lakes Radio Agreement expired renew as required under 47 CFR 80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Valid Great Lakes Radio Agreement now on board.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 March 2008
Resolved
One Type I PFD not in serviceable condition as required under 46 CFR 25.25.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2008
Resolved 19 March 2008
Resolution: PFD replaced, corrected on the spot.
Communications › Radio Communications › EPIRB
Issued 19 March 2008
Resolved
Provide proof that EPIRB has been registered to the "KRISTA S", as required under 46 CFR 25.26-20
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: EPIRB is now registered to the "KRISTA S".
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 19 March 2008
Resolved
Coast Guard Local Notice To Mariners needed on board as required under 33 CFR 164.7 (b)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Local Notice To Mariners now on board.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 March 2008
Resolved
Remote Fuel Shutoff not operating as required under 46 CFR 27.207.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2008
Resolved 19 March 2008
Resolution: Corrected on the spot.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 March 2008
Resolved
Remote Fuel Shutoff needs to be labeled with operating instructions as required under 46 CFR 27.207
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Fuel Shutoffs now labeled with operating instructions.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 March 2008
Resolved
Life Light not working on Starboard Ring Buoy as required under 46 CFR 25.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Life Light now working.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 March 2008
Resolved
Circuit Breaker panel in Generator romm needs labeling, "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Circuit Breaker panel now labeled.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 March 2008
Resolved
Electric outlet by galley sink should be GFI type, "Good Marine Practice"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: GFI outlet now installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 March 2008
Resolved
Globe needed over light fixture over galley sinks, "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Globe now installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 March 2008
Resolved
Alcohol testing kits expired, replace as required under 46 CFR 16.240
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Alcohol test kits have been replaced.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 19 March 2008
Resolved
Re-Secure/weld Rudder Angle indicator switch box located at stern steering assembly, "Good Marine Practice"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 4 June 2008
Resolution: Rudder Angle indicator switch box has been repaired.
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 January 2006
Resolved
Need lighted magnetic compass or swing meter as required under 33 CFR 164.72(a)(4)
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 27 February 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 24 January 2006
Resolved
Fire Extinguishers in the engine room not in approved brackets as required on the extinguisher label
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 27 February 2006
Communications › Alarms/Indicators › General Alarm
Issued 24 January 2006
Resolved
General alarm needs flahing red light as required under 46 CFR 27.201 (a)(3). general alarm light is white
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 27 February 2006
Fire Fighting › Fire Main › Condition
Issued 24 January 2006
Resolved
Need to energize fire pumps remotely from machinery space remote is in machinery space. As required under 46 CFR 27.301
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 27 February 2006
Navigation › Collision/Grounding Avoidance
Issued 9 April 2002
Resolved
MARINE RADAR NOT FUNCTIONING 33 CFR 164.72 (a)(1) LEGACY COMPONENT DESC: Radar
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: RADAR NOW WORKING
Navigation › Piloting/Steering
Issued 9 April 2002
Resolved
NO MAGNETIC COMPASS ON BOARD 33 CFR 164.72(a)(4) LEGACY COMPONENT DESC: Magnetic Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: MARINE COMPASS NOW ON BOARD
Operations/Management › Navigation Safety
Issued 9 April 2002
Resolved
NO MARINE CHARTS OF AREA ON BOARD 33 CFR 164.72(b)(1) LEGACY COMPONENT DESC: Carriage of Charts and Publications
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: MARINE CHARTS NOW ON BOARD
Operations/Management › Navigation Safety
Issued 9 April 2002
Resolved
NO COAST GUARD LOCAL NOTICE TO MARINERS ON BOARD 33 CFR 164.72(b)(2) LEGACY COMPONENT DESC: Carriage of Charts and Publications
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: LOCAL NOTICE TO MARINERS NOW ON BOARD
Operations/Management › Drills/Instruction
Issued 9 April 2002
Resolved
NO CREW TRAINING REQUIREMENTS 46 CFR 27.245 LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: CREW TRAINING REQUIREMENTS MET
Fire Fighting › Fixed Fire Detection System
Issued 9 April 2002
Resolved
GENERAL ALARM PLACARD NOT POSTED NEAR FLASHING LIGHT/ AUDIBLE ALARM IN ENGINE SPACE 46 CFR 27.205 LEGACY COMPONENT DESC: General Alarm Placard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: GENERAL ALARM PLACARD NOW POSTED
Fire Fighting › Fixed Fire Detection System
Issued 9 April 2002
Resolved
FIRE DETECTION SYSTEM NOT CERTIFIED 46 CFR 27.210
& NO VISIBLE WARNING LIGHT
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: FIRE DETECTION TO BE CERTIFIED
Fire Fighting › Remote Fuel Shutoff
Issued 9 April 2002
Resolved
REMOTE FUEL OIL SHUTOFF NOT INSTALLED 46 CFR 27.230
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: REMOTE FUEL OIL SHUTOFF NOW INSTALLED
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 April 2002
Resolved
FIRE EXTINGUISHERS EXPIRED 46 CFR 25.230-10 LEGACY COMPONENT DESC: Service
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: FIRE EXTINGUISHERS SEVICED VALID CONDITION
Documentation › Markings/Placards
Issued 9 April 2002
Resolved
OFFICIAL NUMBER NOT WELDED ON INTERIOR STRUCTURE OF HULL 46 CFR 67.121 LEGACY COMPONENT DESC: Official Number
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2002
Resolution: OFFICIAL NUMBER NOW WELDED ON HULL