← All vessels
WEEKS 3301
Freight Barge · Barge class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named WEEKS 3301 · WEEKS MARINE, INC. operator of record, 2023
WEEKS 3301 is a 2004 freight barge. The Coast Guard has recorded 36 inspections since 2004, most recently in January 2026, along with 43 deficiencies.
Records from 2004 to 2026. Most recent: inspection, 22 January 2026.
- Built
- 2004
- Last inspected
- 22 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 43 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1159982
WDK6030
703964
Flag
UNITED STATES
303682000
Maury page id
psix-703964
Inspections, by type
…with no type recorded2
Years with a record
23 calendar years (2004–2026)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)145.9 ft × 54.0 ft × 11.0 ft
Registered tonnagegross 1,035 / net 310
ITC dimensions (L × B × D)145.9 ft × 54.0 ft × 11.0 ft
ITC tonnagegross 1,035 / net 310
BuilderC AND C MARINE LLC · BELLE CHASSE, LA, UNITED STATES · built 2004
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 30 April 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1035 - Convention (Subpart B), Gross Ton
310 - Convention (Subpart B), Net Ton
310 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK6030MMSI 303682000 · active · compulsorily equipped · granted 20 December 2018, expires 20 December 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 36
22 January 2026
COI Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8288406
12 February 2025
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8078749
18 October 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8021031
1 July 2024
Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7946405
15 August 2023
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7764346
28 April 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7677758
2 December 2022
Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7603215
15 September 2022
Administrative Inspection · Examination of Repairs · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7561993
21 October 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7345565
25 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7296629
30 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7272640
28 September 2020
Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7066906
1 September 2020
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7047327
1 September 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7056281
29 May 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6698539
18 October 2018
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6563519
13 November 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6305541
16 August 2017
Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6242421
10 November 2016
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6042222
13 October 2015
Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5741672
11 February 2015
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5067097
25 August 2014
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4964835
27 September 2013
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4717021
19 November 2012
Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4487651
13 September 2012
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4439880
15 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4245217
7 October 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4163129
13 January 2011
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3925983
13 January 2011
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3926737
17 November 2010
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3893842
20 January 2009
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3395192
14 January 2008
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3130865
18 September 2007
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3060798
29 November 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2831005
20 October 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2531489
3 September 2004
Initial Certification · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2185486
Deficiency record · 43
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 October 2024
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Vessel's rescue boat was not operational due to a faulty kill switch. Vessel can operate when inspected towing vessel is in vicinity.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 October 2024
Resolved
Approved portable fire extinguishers and semi-portable fire extinguishing systems must be installed in accordance with table 1 to § 95.50-10(b). Vessel had 10-BC portable fire extinguisher next to flammable storage locker, needs to be 40-B.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 October 2024
Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. Fire
extinguisher at crane pedestal has rusted out bottom
and damaged hose from improper stowage. Fire
extinguisher hose at station 13 is damaged.
Both not in ready for use condition.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 October 2024
Resolved
The installation of all systems of an electrical engineering or interior communication nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. Vessel had circuit breaker for deck crane light immediately trips upon reset.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 October 2024
Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. Lifebuoy self-igniting light not operational.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 August 2023
Resolved
Each side of the rescue boat bow must be marked with the name of the vessel and hailing port. Name and hailing port not marked on bow of rescue boat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 August 2023
Resolved
General construction vessel shall be to minimize fire hazards. Bulkhead between pump rooms are not sealed. 2 penetrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 May 2023
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. The requirements of § 58.10–5 (a), (c), and (d) shall apply to diesel engine installations. Engine design. All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Generator was able to start, but not able to take load due to megmeter internal safety; provide technician report identifying reason generator can not take load and operate as intended.
46 CFR 96.03-1(a)
46 CFR 58.10-10(a)
46 CFR 58.10-5 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 May 2023
Resolved
All marine engineering details such as piping, valves, fittings, boilers, pressure vessels, etc., and their appurtenances installed on the vessel, shall be designed, constructed, and installed in accordance with the provisions of subchapter F (Marine Engineering) of this chapter. Each valve must close with a right-hand (clockwise) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Spring on butterfly valves for bilge system were not working as designed, maintenance or replace.
46 CFR 90.20-1 (a)
46 CFR 56.20-9 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2023
Resolved
Current carrying components must be protected from accidental contact by personnel operating or routinely servicing the device. MSD aerator is not hard wired to vessel. Hard wire Marine Sanitation Device following electrical guidelines for junction boxes.
33 CFR 159.95(c)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 May 2023
Resolved
Machinery space openings in position 1 or 2 shall be properly framed and efficiently enclosed by steel casings of ample strength. Access openings in such casings shall be fitted with doors complying with the requirements of 42.15-10(a). Byfold watertight door has gaps at top and bottom of connection point; make watertight.
46 CFR 42.15-35
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 May 2023
Resolved
All marine engineering details such as piping, valves, fittings and their appurtenances installed on the vessel shall be designed, constructed, and installed in accordance with the provisions of Subchapter F of this chapter. There is a valve on the hot water tank that needs to be piped to the bilge.
46 CFR 96.03-1(a)
46 CFR 56.50-25
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 11 May 2023
Resolved
The installation of all systems of an electrical engineering or interior communications nature together with the details of design, construction, and installation shall be in accordance with the requirements of subchapter J. Systems of this type include general alarm systems. The general alarm did not function as designed under ships power or emergency power.
46CFR96.05-1(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2023
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date, except as required in paragraph (b) of this section. Vessel notified USCG that they were operating outside of 3 month window for annual inspection. Directed vessel to cease operation immediately until annual inspection is complete. Vessel must complete satisfactory inspection prior to conducting cargo operations.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 28 April 2023
Resolved
The requirements of 58.10-5(a), (c) and (d) shall apply to diesel engine installations. Exhaust pipe installations must conform to the requirements of ABYC P-1 and part 1, section 23 of NFPA 302 (both incorporated by reference; see 46 CFR 58.03-1). Protective guards, jacketing or covers shall be provided wherever persons or gear might come in contact with the exhaust system where the temperature exceeds 200°F(93°C). Engine maintenance or engine repair may make the temporary removal of this protection necessary. Replace/repair lagging on generator.
46 CFR 58.10-10 (a)
46 CFR 58.10-5(d)
ABYC P-1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020
Resolved
There must be ground detection for each: electric propulsion system, ship's service power system, and lighting system; The 240 volt breaker panel in the engine room aft of ship's office showed a ground fault of 6 amps; Vessel shall show proof that the ground fault has been troubleshot, found, and corrected IAW 46 CFR 111.05-21 NLT 15SEP20; To the satisfaction of the OCMI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 September 2020
Resolved
The inspector will determine if the tests and inspections required by 97.15-60 of this subchapter have been conducted; Fire Extinguisher #3 did not have its annual inspection by a certified servicing agency; Ensure fire extinguishers are serviced IAW 46 CFR 91.25-20; To the satisfaction of the OCMI.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 14 October 2015
Resolved
REPAIR FUEL LEAK ON #2 AUXILIARY GENERATOR, AS ORIGINAL.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 14 October 2015
Resolved
REPAIR LEAK ON OIL DRAIN LINE FOR TURBOCHARGER ON #1 AUXILIARY GENERATOR, AS ORIGINAL.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 October 2015
Resolved
REPAIR LEAKS ON EXHAUST MANIFOLD ON #1 AND #2 PRIME MOVERS FOR DREDGE PUMPS.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 September 2013
Resolved
Repair emergency lighting in aft engine room.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 27 September 2013
Resolved
Repair engine alarm in aft engine room.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 September 2013
Resolved
Show evidence of lifesaving equipment maintenance records.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 September 2013
Resolved
Provide proof or enrollment in and compliance with drug and alcohol testing program.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 27 September 2013
Resolved
Provide appropriate number of line throwing device and charges.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 September 2013
Resolved
Provide new first aid kit.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 27 September 2013
Resolved
Repair emergency lighting in forward engine room.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 7 October 2011
Resolved
Auxilary generator was removed for servicing at time of inspection. Rep will call for CGMI to witness the operation of generator and over speed of prime mover when work is complete.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 7 October 2011
Resolved
All e-lights not working due to either dead batteries or broken lights, proper operation must be proved to CGMI.
Construction/Loadline › Structures › Door
Issued 7 December 2010
Resolved
Repair or replace forward watertight door and starboard aft watertight door. Check hinges, pins, gaskets, and loose dogs and ensure proper operation. (All watertight doors)
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 7 December 2010
Resolved
Install pressure gages on main deck air receivers.
Engineering › Compressed Air System (start air) › Valve
Issued 7 December 2010
Resolved
Bench test relief valves on main deck air receivers to prove proper operation or replace with new relief valves.
Electrical › Electric Generation Source (service) › Generator
Issued 7 December 2010
Resolved
Overspeed outboard (main) generator and test low lube oil shutdown
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 December 2010
Resolved
Post donning instructions for life jackets where life jackets are stowed.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 17 November 2010
Resolved
Main Deck Air Receiver tests have not been conducted as required, make ready for internal inspection to the satisfaction of the attending USCG Marine Inspector.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 November 2010
Resolved
Aft starboard side ring buoy missing retroreflective tape, replace buoy and/or retape buoy to the satisfaction of the attending USCG Marine Inspector
Construction/Loadline › Hull › Bracket
Issued 18 September 2007
Resolved
Stanchion and diagonal stiffener in middle tank centerline aft of house damaged and required renewal. Bilge brackets in this and adjacent spaces damaged and require renewal. Damage appears to be due to grounding in past.
Lifesaving › Inflatable Liferafts › Painter
Issued 29 November 2006
Resolved
The painter was not permanently attached to the weak link.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 November 2006
Resolved
Life line was not deployable as stowed in PVC piping.
Engineering › Diesel Engine (propulsion-electric) › Crosshead Assembly
Issued 29 November 2006
Resolved
Air supply hose needed chaffing gear on the port main engine.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 November 2006
Resolved
Emergency lighting in the engine room had dead batteries.
Engineering › Fuel Oil Service System › Hose
Issued 20 October 2005
Resolved
Several lengths of flexible fuel hose exceed the 30-inch max length requirement.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 20 October 2005
Resolved
Manual launching of inflatable liferaft from stowed location requires it to be lifted over 1 foot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.