MAURY USCG vessel records
← All vessels

ASTRO PHOENIX

ASTRO PHOENIX is a 2004 tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in November 2019, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2019. Most recent: inspection, 25 November 2019.

Built
2004
Last inspected
25 November 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 November 2019
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9280885
704194
Flag
GREECE
Maury page id
psix-704194

Documentation record

Tonnage as PSIX records it80620 - Convention (Subpart B), Gross Ton
52154 - Convention (Subpart B), Net Ton
186655 - Displacement, Ton
159055 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

25 November 2019 COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6862187
20 November 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6858914
1 May 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6667764
19 July 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6485081
8 March 2018 ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-TVE Annual
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6360296
28 February 2017 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6096079
19 January 2017 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6072178
12 January 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6070212
21 February 2016 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5818349

Deficiency record · 3

Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 8 March 2018 Resolved
1835 - PSCO observed water leaking from the flue gas supply on the IGS scrubber. PSCO was unable to verify source of leak due to installed lagging. 74 SOLAS (2009) II-2/4.5.5.1.1 FSS Code 15.2.3.1.6.2
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2018
Resolved 10 March 2018
Resolution: Permanent repairs made to scrubber flue gas intake. Class satisfactorily pressure tested repairs. See attached class report for further details.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 8 March 2018 Resolved
1835 - PSCO observed #1 blower on the IGS has a sheared bolt on the lower flange intake and on the same blower the discharge remote operated control valve was missing its regulator/filter. On the #2 blower the discharge remote operated control valve solenoid was inoperable. 74 SOLAS (2009) II-2/4.5.5.1.1 FSS Code 15.2.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2018
Resolved 10 March 2018
Resolution: As per Class report Bolts were renewed and blower discharge valve was tested satisfactorily.
Fire Fighting › Portable Foam Applicators › General
Issued 8 March 2018 Resolved
0720 - PSCO observed portable foam containers were supplied to the vessel in 2013, the crew was unable to produce analysis report. 74 SOLAS (2009)II-2/10.3.1 FSS Code 4.3.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 March 2018
Resolved 10 March 2018
Resolution: As Per Class report; Class has placed a Condition of Authority on the vessel requiring foam analysis to be carried out prior to departure.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.