Records from 2004 to 2024. Most recent: inspection, 1 November 2024.
Inspection history · 34
1 November 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8028083
19 October 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8021455
15 June 2023
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7715907
6 June 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7702804
3 July 2022
Ballast Water Examination · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7493933
15 May 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6414666
18 February 2017
COE-Dockside · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6090815
21 November 2016
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6044943
28 September 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6010454
25 July 2016
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5953445
24 May 2016
Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5886213
10 January 2016
COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5792927
27 October 2015
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5752531
17 September 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5721303
15 September 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5719051
28 July 2015
Enhanced Seaway Inspection (Massena only) · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5199721
17 June 2012
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4346418
25 February 2012
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4251090
25 February 2012
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4251092
20 February 2012
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4247814
8 February 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4237926
3 April 2009
ISM Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3441793
15 October 2007
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3080264
9 October 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3077787
18 June 2007
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2967798
18 June 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2967872
22 February 2007
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2876033
23 May 2006
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2656865
8 March 2006
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2599132
2 March 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2594450
27 May 2005
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2365724
27 July 2004
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2146115
26 July 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2148221
22 July 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2142024
Fire Fighting › International Shore Connection › Bolts
Issued 28 September 2016
Resolved
International Shore Connection with 4 bolts required. Each International Shore Connection had only 2 bolts available.
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 28 September 2016
Resolution: Corrected on the spot. Bolts added to International Shore Connection storage points.
Construction/Loadline › Structures › Deck Plating
Issued 28 September 2016
Resolved
Structural strength of ships to be maintained to class standards. Crane cradle on port bridge wing was cracked at base reducing the structural integrity of the deck. 50(a) resolve to satisfaction of class.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 21 November 2016
Resolution: MSD ST THOMAS RCVD CLASS REPORT TO RECTIFY DEFICIENCY. CLASS REPORT UPLOADED.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 February 2012
Resolved
0660-Lifejacket-Stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the organization. PSCO observed no life jacket stowed on deck with the forward liferaft as indicated on the approved life saving plan. CITE: SOLAS 74(a) III/20.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 June 2012
Resolution: Crew installed life jackets in container next to forward life raft.
Fire Fighting › Fire Hydrants › Condition
Issued 3 April 2009
Resolved
Starboard side fire hydrant valve is not in good working order, when system was pressurized excessive water leaked out the valve and decreased vessel's fire fighting capability.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 April 2009
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 April 2009
Resolved
One fire suit were found not to be in good working. Fire suit pants were worn and heat reflective material pealing off.
Action required: 705 - Other - as specified
Resolved 3 April 2009
Resolution: Deficiency rectified to satisfaction of the Coast Guard.
Lifesaving › Lifebuoys › Size
Issued 3 April 2009
Resolved
Bridge wing life rings were not of sufficient weight.
Action required: 705 - Other - as specified
Resolved 3 April 2009
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 April 2009
Resolved
Oily water separator did not pass PSCO examination. During operational test of the equipment oil was witnessed discharging to the drain line on the overboard discharge side of the three way valve. When system shifted from the over board discharge to oil dump the oil content meter continued to read 0 ppm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2009
Resolution: Received Class and technician reports, satisfactory repairs were made and OWS was found in good working order. Vessel Was released from Detention. -MST1
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 3 April 2009
Resolved
Ships computerized Safety Management System (SMS) was not accessible and no hard copies were available aboard the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2009
Resolution: Ships master provided objective evidence that the master was able to access the electronic version of the ships SMS, therefore that deficiency has been satisfied.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 2 March 2006
Resolved
Vessel's incinerator is inoperable. Incinerator will not ignite. Violation of 33 CFR 151.23(a)(1). Rectify to satisfaction of CG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2006
Resolved 4 March 2006
Resolution: RECIEVED TECH. REPORT STATING PROPER REPAIRS MADE TO INCINERATOR.