MAURY USCG vessel records Sign in
← All vessels

AMISTAD

AMISTAD is a 2000 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1999, most recently in April 2025, along with 107 deficiencies — 2 with no resolution recorded — and 2 casualty investigations between 2012 and 2022.

Records from 1999 to 2025. Most recent: inspection, 30 April 2025.

Built
2000
Last inspected
30 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ9672
Flag
UNITED STATES
369547000 (licence lapsed)
Maury page id
psix-7052

Inspections, by type

…with no type recorded6
…past their stated due date2
Years with a record 24 calendar years (1999–2025)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)78.5 ft × 23.0 ft × 10.0 ft
Registered tonnagegross 90 / net 81
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMYSTIC SEAPORT · MYSTIC, CT, UNITED STATES · built 2000
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portNEW HAVEN, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Simplified, Gross Ton
81 - Simplified, Net Ton
137 - Dead Weight, Ton
137 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ9672MMSI 369547000 · expired · compulsorily equipped · granted 2 July 2010, cancelled 3 October 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

30 April 2025 Attraction Vessel Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8121637
29 April 2024 Attraction Vessel Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7901152
13 November 2023 Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7824224
31 March 2023 Attraction Vessel Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7648215
5 July 2022 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7500606
4 April 2022 Attraction Vessel Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7412274
12 October 2021 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7331137
11 June 2021 Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7224875
15 July 2020 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7005290
28 May 2020 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6964033
27 March 2020 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6932308
7 October 2019 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6829495
10 July 2019 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6741908
29 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6526303
22 August 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6521815
8 August 2018 Examination of Repairs · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6505838
8 August 2018 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6513281
10 July 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6474402
13 July 2017 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6188682
18 November 2015 Construction Oversight · Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5766200
1 August 2014 Deficiency Check · Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4944418
11 June 2014 In-Service Inspection · Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4898519
10 March 2014 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4813270
13 July 2012 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4373312
18 June 2012 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4348178
13 June 2012 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4342846
12 June 2012 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4342672
31 March 2010 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3707429
18 December 2009 DAPI Audit · Attraction Vessel Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3652380
8 July 2009 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3520260
5 May 2009 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3449165
7 July 2008 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3261297
23 June 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3248403
5 June 2007 Deadweight Survey · Inclining Experiment
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2953082
18 September 2006 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2782259
28 June 2006 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2694502
4 April 2006 Deficiency Check · Plan Review (Other than "T") · Administrative Inspection · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2616181
11 October 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2512205
12 July 2005 Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2423641
10 May 2005 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2354138
21 April 2005 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2339475
27 December 2004 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2265076
24 September 2004 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2203798
18 August 2004 Annual Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2175168
14 October 2003 In-Service Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1932402
22 August 2003 In-Service Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1890027
16 July 2003 Uninspected Other
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1848087
1 July 2003 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1832286
4 June 2003 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1809722
28 March 2003 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1770439
7 March 2003 In-Service Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1753471
28 January 2003 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1815868
25 November 2002 In-Service Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1710530
2 August 2002 Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1655707
1 August 2002 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1803940
11 July 2002 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1644158
13 December 2001 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1077096
6 August 2001 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1070112
6 June 2001 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1440503
7 March 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1463652
24 August 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1052552
12 July 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 822691
23 June 2000 Plan Review "T" Boat · Inclining Experiment · MARPOL Annex V Examination · Initial Certification
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1415381
25 March 2000 Plan Review "T" Boat · Hull Examination · Construction Oversight
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1469626
23 July 1999 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1070613

Deficiency record · 107

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 July 2020 Resolved
Provide fire servicing report for portable and fixed firefighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 26 July 2020
Resolution: Report provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 July 2020 No resolution recorded
Provide pressure gauge for fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 July 2020 Resolved
Provide EPIRB. EPIRD battery and registration expired. Vessel limited from operating on the high seas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 28 July 2020
Resolution: New epirb and registration provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020 No resolution recorded
Renew life lines on 02 life rings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 July 2019 Resolved
Provide 03 hand red flares. Vessel restricted to day time operations only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 22 July 2019
Resolution: Recived photos and reciept from vessel rep. showing new hand red flares.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 July 2019 Resolved
Provide independent modular smoke detectors in accomodation spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 22 July 2019
Resolution: Recieved photo and reciept of new smoke detectors on board the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018 Resolved
Vsl is broadcasting greater than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 July 2019
Resolution: Proper lenght entered
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 24 August 2018 Resolved
Replace thimbles on 2 lines PS and STBD IWO of Bow sprit.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 September 2018
Resolution: Thimbles replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 August 2018 Resolved
Conduct wooden boat underway test.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2018
Resolved 7 September 2018
Resolution: Conducted underway exam
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 August 2018 Resolved
Inspect rigging IWO of the bow sprit and dolphin striker. Re-tune head rig.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2018
Resolution: Area inspected and re-tuned. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018 Resolved
Inspect CO2 bottle in engine room. Portable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 7 September 2018
Resolution: Bottles examined. Tag was wrong
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2018 Resolved
Replace safety tag on manual pull handle for CO2 fire engine system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 7 September 2018
Resolution: Safety tag updated.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 July 2018 Resolved
Secure high water alarm bilge in galley area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 7 September 2018
Resolution: High water alarm secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2018 Resolved
replace battery in float light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 7 September 2018
Resolution: Float light replaced.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 13 July 2017 Resolved
Label child life jacket with vessel name.
Condition: Improper/Lack of Maintenance
Due 13 August 2017
Resolved 10 August 2017
Resolution: Life jackets labeled.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 13 July 2017 Resolved
Label and adjust emergency hatch
Condition: Improper/Lack of Maintenance
Due 13 August 2017
Resolved 10 August 2017
Resolution: Hatch adjusted and labeled.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 July 2017 Resolved
Provide epirb reg stickers.
Condition: Improper/Lack of Maintenance
Due 13 August 2017
Resolved 10 August 2017
Resolution: Epirb removed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 25 August 2016 Resolved
Replace cooling hose on both MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2016
Resolved 13 October 2016
Resolution: Both hoses replaced.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 25 August 2016 Resolved
Repair cooling fixed joint above STBD MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Joint repaired.
Fire Fighting › Fire Main › Pressure
Issued 25 August 2016 Resolved
Repair pressure guage on fire main
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2016
Resolved 13 October 2016
Resolution: Guage replaced.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 August 2016 Resolved
Secure wires and junction box.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Junction box secure.
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 August 2016 Resolved
Provide passenger count list program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2016
Resolved 13 October 2016
Resolution: Passenger count program initiated.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 25 August 2016 Resolved
Provide pre-employment testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2016
Resolution: Letter received that all crew members are enrolled in a drug consortium.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 25 August 2016 Resolved
Provide drill log book.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Drills are being logged in offical log bood in red.
Personnel › Certificates/Documents/Licenses › PIC
Issued 25 August 2016 Resolved
Provide a letter designation as a senior deck hand.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2016
Resolved 13 October 2016
Resolution: Letter provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 25 August 2016 Resolved
Test single side band radio.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Radio tested
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 August 2016 Resolved
Replace emergency battery banks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Battery bank replaced.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 August 2016 Resolved
Provide light list and Coast pilot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Light list and Coast pilot provided.
Operations/Management › Vessel Traffic Service › Sailing Plan
Issued 18 August 2016 Resolved
Provide sail plan
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Sail plan provided.
Navigation › Piloting/Steering › Notices to Navigation
Issued 18 August 2016 Resolved
Provide notice to mariners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Notice to mariners provided.
Navigation › Piloting/Steering › Marine Charts
Issued 18 November 2015 Resolved
Provide charts and pubs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2016
Resolution: Charts and pubs provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 July 2012 Resolved
Provide light fixture where missing in aft cabin/prove operation of extinguished cabin lights.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 July 2012 Resolved
Remove stores from lifejacket box on deck.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 July 2012 Resolved
Replace lines on floating lights.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 July 2012 Resolved
Secure light by MSD tank in galley bilge.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 July 2012 Resolved
Secure junction box in galley/bilge area.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 July 2012 Resolved
Replace cap on aft MSD tank.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 13 July 2012 Resolved
Mount aft panel on 12KW genset.
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Engineering › Fuel Oil Service System › Filter
Issued 13 July 2012 Resolved
Replace valve handle on RACOR filter housing.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Engineering › Fuel Oil Service System › Piping
Issued 13 July 2012 Resolved
Renew flexible fuel supply line from day tank to hard pipe.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 18 June 2013
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 July 2012 Resolved
Prove operation of bilge alarms in focsle, aft salon, E.R.,
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 July 2012 Resolved
Replace #3 battery.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Communications › Alarms/Indicators › Fire Alarm
Issued 13 July 2012 Resolved
Remove unused heat sensor in Engine Room and put cover on J box.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 July 2012 Resolved
Prove operation of Emergency lighting.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Resolution: Attended vessel. Deficiency corrected.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 July 2012 Resolved
Prove enrollment in drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2012
Resolved 16 May 2013
Resolution: Owner/Operator submitted records of enrollment with drug consortium (ASTS) and documentation of drug testing for crewmembers in safety sensitive positions (see Activity # 4588151).
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 July 2012 Resolved
Replace elbow on vent of MSD tank.
Action required: 705 - Other - as specified
Due 16 August 2012
Resolved 26 July 2013
Resolution: Elbow replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 June 2008 Resolved
Lights in void below galley were bare bulbs with no protective cover.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 7 July 2008
Resolution: Protective covers in place over light bulbs in void below galley.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 23 June 2008 Resolved
Fuel transfer pump for galley stove leaking.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 25 June 2008
Resolution: Repairs made to fuel transfer pump.
Lifesaving › Hand Flares › Not on Board
Issued 23 June 2008 Resolved
Missing 2 Red Handheld Flares
Action required: 705 - Other - as specified
Resolved 25 June 2008
Resolution: Provided required flares
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 June 2008 Resolved
No current Notice to Mariner on board.
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 7 July 2008
Resolution: Current Notice to Mariners on board.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 23 June 2008 Resolved
Lube Oil Alarm for Port Main engine inoperable
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 25 June 2008
Resolution: Lube Oil Alarm functional
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 June 2008 Resolved
Bilge Alarm in forecastle inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2008
Resolution: Bilge alarm repaired and operating properly
Accommodation/Occupational Safety › Potable Water System › General
Issued 23 June 2008 Resolved
Sink drain inoperable.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 25 June 2008
Resolution: Sink drain repaired.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 23 June 2008 Resolved
No locking device on MSD overboard discharge valve.
Action required: 705 - Other - as specified
Due 7 July 2008
Resolved 25 June 2008
Resolution: Locking device in place on overboard discharge valve.
Documentation › Logs/Records › Drug Test Records
Issued 23 June 2008 Resolved
No current DAPI audit.
Action required: 705 - Other - as specified
Due 7 July 2008
Resolved 7 July 2008
Resolution: All personnel on board had recent drug test and are enrolled in random program.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 23 June 2008 Resolved
Fixed Fire Extinguishing System (Fire Boy) did not operate properly in normal and override modes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2008
Resolution: Demonstrated proper operation of fixed fire extinguishing system.
Communications › Radio Communications › EPIRB
Issued 18 September 2006 Resolved
Provide EPRIB registration sticker.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2007
Resolution: EPIRB Registered
Navigation › Piloting/Steering › Marine Charts
Issued 18 September 2006 Resolved
Renew outdated/Uncorrected charts for new Haven Harbor and Long Island Sound.
Condition: Improper/Lack of Maintenance
Due 25 September 2006
Resolved 19 June 2007
Resolution: Charts updated
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 September 2006 Resolved
Provide updated Light List and U.S. Coast Pilot
Condition: Improper/Lack of Maintenance
Due 25 September 2006
Resolved 19 June 2007
Resolution: Manuals provided
Operations/Management › Pollution › Removal Methods/Procedures
Issued 18 September 2006 Resolved
Provide waste management plan IAW 33CFR151.57
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2007
Resolution: Waste Management plan instituted
Communications › Audible Communications › SPD (Other)
Issued 18 September 2006 Resolved
Provide public address system IAW 46CFR184.610(b).
Condition: Improper/Lack of Maintenance
Due 18 October 2006
Resolved 21 June 2007
Resolution: Waiver granted by OCMI
Electrical › Electrical Distribution System (service) › Cable
Issued 18 September 2006 Resolved
Removed galley fan dead end cable.
Condition: Placed in Improper Service
Due 25 September 2006
Resolved 21 June 2007
Resolution: Cable removed
Construction/Loadline › Structures › Superstructure
Issued 28 June 2006 Resolved
Vessel is not to operate with passengers past 01DEC06 unless permenant repairs are made to fore mast and approved by attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2006
Resolved 19 June 2007
Resolution: Inspection Completed
Electrical › Lighting (service) › Lighting Feeder
Issued 4 April 2006 Resolved
Complete installation of Rack lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Resolution: Installation completed
Engineering › Fuel Oil Service System › Piping
Issued 4 April 2006 Resolved
Repair Fuel leak to aft tank at manifold
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Resolution: Fuel leak repaired
Communications › Public Address System › Announcing Station
Issued 4 April 2006 Resolved
Prove operation of PA system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Resolution: Waiver granted by OCMI
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 4 April 2006 Resolved
Prove operation of SSB Radio
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Resolution: Radio installation completed and tested SAT
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 4 April 2006 Resolved
Master must sign crew
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Resolution: List signed
Accommodation/Occupational Safety › Ventilation › General
Issued 12 July 2005 Resolved
USCG Marine inspector to conduct as-built verification of dorade vents & fans as per approved plans.
Condition: Design Flaw
Due 19 June 2007
Resolved 19 June 2007
Resolution: Installation completed
Lifesaving › Lifebuoys › Approval
Issued 22 April 2005 Resolved
Miising 2 corrosion resistant clips.
Due 22 May 2005
Resolved 26 April 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 April 2005 Resolved
Label all emergency lighting.
Due 29 April 2005
Resolved 26 April 2005
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 22 April 2005 Resolved
Prove proper op of MDE and SSDG alarms and shutdowns
Due 29 April 2005
Resolved 26 April 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 April 2005 Resolved
Missing current CG light list IAW 46 CFR 184.420.
Due 22 May 2005
Resolved 26 April 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 22 April 2005 Resolved
Post emergency instructions tailored for vessel IAW 46CFR185.510.
Due 22 May 2005
Resolved 26 April 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 April 2005 Resolved
Lifesaving maintenance record up to date
Due 22 May 2005
Resolved 26 April 2005
Communications › Internal Communications System › Portable Radios
Issued 22 April 2005 Resolved
Install fixed internal fixed communication system.
Due 29 April 2005
Resolved 26 April 2005
Resolution: Provided 1 additional portable radio (2 already on board) capable being of being used to communicate anywhere on vessel to engine room.
Communications › Audible Communications › SPD (Other)
Issued 22 April 2005 Resolved
Install fixed PA system.
Due 22 May 2005
Resolved 26 April 2005
Resolution: Allowed use of bullhorn in conjunction with general alarm to meet required public address system. Bullhorn provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 August 2004 Resolved
Install lagging on P&S side horizontal exh pipes.
Due 17 September 2004
Resolved 18 October 2004
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 August 2004 Resolved
Properly mark all life jacket stowage.
Due 17 September 2004
Resolved 22 April 2005
Communications › Alarms/Indicators › General Alarm
Issued 18 August 2004 Resolved
Install general alarm operable from operating station.
Due 17 September 2004
Resolved 18 October 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 August 2004 Resolved
Install belt guard on bilge pump.
Due 17 September 2004
Resolved 25 October 2004
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 18 August 2004 Resolved
Repair MDE L/O gage.
Due 17 September 2004
Resolved 20 August 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 August 2004 Resolved
Modify float light attachement. And renew hydro release.
Due 17 September 2004
Resolved 22 April 2005
Communications › Radio Communications › EPIRB
Issued 18 August 2004 Resolved
Reposition EPIRB for better access.
Due 17 September 2004
Resolved 20 August 2004
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 18 August 2004 Resolved
Manning does not comply with COI. In order to comply a licensed 1st mate or equivilent skill level is needed.
Due 17 September 2004
Resolved 18 October 2004
Pollution Prevention/Response › Prevention Equipment
Issued 4 June 2003 Resolved
Complete USCG as-built verification of two grey water tanks as per MSC ltr H1-0305274 dtd 30May03. LEGACY COMPONENT DESC: Sewage System Tank
Due 5 July 2003
Resolved 4 June 2003
Construction/Loadline › Hull
Issued 2 August 2002 Resolved
Vessel grounding: Provide USCG OCMI with salvage plan for vessel ASAP. LEGACY COMPONENT DESC: Bottom Plating
Due 2 August 2002
Resolved 2 August 2002
Resolution: Plan verbally submitted. Vessel eventually floated freely with tide without assistance.
Construction/Loadline › Hull
Issued 2 August 2002 Resolved
Vessel is not to operate with passengers until a diver's survey report is copied to USCG and assessed for further action. LEGACY COMPONENT DESC: Bottom Plating
Due 2 August 2002
Resolved 2 August 2002
Resolution: Satisfactory diver''''s report filed. Vessel cleared to operate.
Construction/Loadline › Hull
Issued 2 August 2002 Resolved
Until vessel is secured at pier, provide a constant live patrol watch of all belowdecks spaces. Sound fuel tanks at 2 hour intervals. LEGACY COMPONENT DESC: Bottom Plating
Due 2 August 2002
Resolved 2 August 2002
Resolution: Vessel floated freely with tide and escorted to home base without incident.
Documentation
Issued 2 August 2002 Resolved
Provide USCG with report of marine accident CG-2692 within 5 days irt vessel grounding 08/01/02. LEGACY COMPONENT DESC: CG-2692
Due 6 August 2002
Resolved 6 August 2002
Resolution: Rcvd this date; forwarded to investigating officer.
Navigation
Issued 6 June 2001 Resolved
Provide compass deviation table
Condition: Unknown
Due 6 June 2001
Resolved 6 June 2001
Fire Fighting
Issued 6 June 2001 Resolved
Replace plastic trash cans with metal trash cans
Condition: Unknown
Due 6 June 2001
Resolved 6 June 2001
Navigation
Issued 6 June 2001 Resolved
Provide emergency broadcast placard
Condition: Unknown
Due 6 June 2001
Resolved 6 June 2001
Navigation
Issued 23 June 2000 Resolved
PROVIDE FCC RADIOTELEPHONEY SAFETY CERTIFICATE. (VESSEL USE IS PERMISSIBLE WITHIN INLAND WATERS UNDER 47CFR80.5)
Condition: Unknown
Due 23 July 2000
Resolved 30 June 2000
Electrical
Issued 23 June 2000 Resolved
COMPLETE WIRING OF THE VESSEL AND SEAL ALL WTB'S.
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Documentation
Issued 23 June 2000 Resolved
PROVE COMPLIANCE WITH THE DRUG AND ALCOHOL PROGRAM.
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Navigation
Issued 23 June 2000 Resolved
PROVIDE A COMPASS DEVIATION TABLE.
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Lifesaving
Issued 23 June 2000 Resolved
PROVIDE LIGHTS FOR THE LIFE JACKETS. VESSEL IS RESTRICTED TO NOT MORE THAN20 MILES FROM A HARBOR OF SAFE REFUGE (LTD COASTWISE) UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 23 August 2000
Resolved 30 June 2000
Documentation
Issued 23 June 2000 Resolved
PROVIDE AND POST A COPY OF THE STABILITY LETTER.
Condition: Unknown
Due 23 July 2000
Resolved 30 June 2000
Construction/Loadline
Issued 23 June 2000 Resolved
POST BILGE LINE DIAGRAM AND LABEL BILGE VALVE MANIFOLD.
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Documentation
Issued 23 June 2000 Resolved
PROVIDE A COPY OF AS-BUILT PLANS AS NECESSARY.
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Construction/Loadline
Issued 23 June 2000 Resolved
PROVE PROPER OPERATION OF THE BILGE ALARM SYSTEM (AUDIBLE AND VISUAL).
Condition: Unknown
Due 23 July 2000
Resolved 30 June 2000
Fire Fighting
Issued 23 June 2000 Resolved
PROVE PROPER OPERATION OF THE ENGINEROOM FIRE SUPRESSION SYSTEM.
Condition: Unknown
Due 23 July 2000
Resolved 30 June 2000
Electrical
Issued 23 June 2000 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY LIGHTING CIRCUIT AND FIXTURES._x001C_ ALL PERSONNEL TO HAVE PORTABLE ELECTRIC LIGHTS WHILE BELOW DECKS.
Condition: Unknown
Due 23 June 2000
Resolved 23 June 2000
Lifesaving
Issued 23 June 2000 Resolved
CONDUCT A FIRE DRILL AND A MAN-OVERBOARD DRILL USING A RESCUE BOAT THAT COMPLIES WITH 46CFR160.056.
Condition: Unknown
Due 23 July 2000
Resolved 30 June 2000
Navigation
Issued 23 June 2000 Resolved
PROVE PROPER OPERATION OF ALL NAVIGATION LIGHTS. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS.
Condition: Unknown
Due 23 August 2000
Resolved 30 June 2000
Engineering
Issued 23 June 2000 Resolved
PROVE PROPER OPERATION OF THE REMOTELY OPERATED FUEL OIL VALVES.
Condition: Unknown
Due 23 July 2000
Resolved 30 June 2000

Casualty record · 2

12 June 2012Routine · role: Involved in a Marine Casualty · activity 4342672
5 July 2022Routine · role: Involved in a Marine Casualty · activity 7500606
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.